EFFECT OF SCANDIUM ON THE CORROSION BEHAVIOR OF THE CASTING Al-Cu ALLOYS IN NACL SOLUTION

2009 ◽  
Vol 23 (06n07) ◽  
pp. 978-983 ◽  
Author(s):  
WENGUI ZHAO ◽  
JINGUO WANG ◽  
JINGQI HOU ◽  
QICHUAN JIANG

Corrosion behavior of the casting Al - Cu alloys with and without Sc addition was studied by both the immersion test and electrochemical measurement methods. The results show that pitting corrosion was found on the surfaces of these alloys in 3.5 wt .% NaCl solution, while the corrosion resistance of the Al - Cu alloys with Sc is better than that of the Al - Cu alloy without Sc . With increasing Sc content, the corrosion resistance of the present Al - Cu alloys varies significantly, and the 0.1 wt .% Sc alloy has the best corrosion resistance. Also, the corrosion potential of the present alloys with Sc is shifted positively compared with that of the alloy without Sc by electrochemical measurement, indicating that the alloys with Sc have better corrosion resistance. The microstructures of the Al - Cu alloys change from the coarse grains to the fine equiaxed grains due to Sc addition, which is responsible for the reduced susceptibility to corrosion and the enhanced corrosion resistance of the present alloys.

2021 ◽  
Vol 882 ◽  
pp. 35-49
Author(s):  
A.D. Vishwanatha ◽  
Bijayani Panda ◽  
J.N. Balaraju ◽  
Preeti Prakash Sahoo ◽  
P. Shreyas

Corrosion behavior of three carbon steels with increasing galvanized coating thickness of 5.6, 8.4 and 19.2 μm named as T1, T2 and T3, respectively, was studied by immersion test, potentiodynamic polarization and electrochemical impedance spectroscopy in freely aerated 3.5% NaCl solution. The major phase in the corrosion product of all the samples after immersion test was found to be zincite, as determined by X-Ray Diffraction and Fourier Transform Infrared Spectroscopy techniques. The corrosion product on sample T1was well adhered and was compact in most regions. Samples T2 and T3 showed porous and non-adherent growth of corrosion product. Corrosion rates were found to increase with increasing coating thickness. The impedance provided by the coating as well as the substrate was the highest for the sample with thinnest coating (T1). The early exposure of the underlying steel in sample T1 resulted in higher corrosion resistance, which was probably due to the combined effect of zinc corrosion products and Fe-Zn alloy layer. Higher amount of protective γ-FeOOH as well as compact corrosion product could have also improved the corrosion resistance of sample T1. Although the average uniform corrosion resistance was higher for T1, the localized pitting corrosion was also observed, probably due to the thin galvanized layer.


2021 ◽  
Vol 2 (1) ◽  
pp. 61-77
Author(s):  
Hamid Reza Jafari ◽  
Ali Davoodi ◽  
Saman Hosseinpour

In this work, the corrosion behavior and surface reactivity of as-cast and heat-treated nickel aluminum bronze casting alloy (UNS C95800) in 3.5 wt% NaCl solution is investigated under stagnant and flow conditions. Increasing flow rate conditions are simulated using a rotating disk electrode from 0 to 9000 revolutions per minute (rpm). Optical micrographs confirm the decrease in the phase fraction of corrosion-sensitive β phase in the microstructure of C95800 after annealing, which, in turn, enhances the corrosion resistance of the alloy. Electrochemical studies including open circuit potentiometry, potentiodynamic polarization, and electrochemical impedance spectroscopy are performed to assess the effect of flow rate and heat treatment on the corrosion of samples at 25 and 40 °C in 3.5 wt% NaCl solution. For both as-cast and heat-treated samples, increasing the flow rate (i.e., electrode rotating rate) linearly reduces the corrosion resistance, indicating that the metal dissolution rate is significantly affected by hydrodynamic flow. Increasing the solution temperature negatively impacts the corrosion behavior of the as-cast and heat-treated samples at all flow conditions.


2013 ◽  
Vol 83 (5) ◽  
pp. 864-869 ◽  
Author(s):  
Elisa J. Kassab ◽  
José Ponciano Gomes

ABSTRACT Objective: To assess the influence of fluoride concentration on the corrosion behavior of nickel titanium (NiTi) superelastic wire and to compare the corrosion resistance of NiTi with that of beta titanium alloy in physiological solution with and without addition of fluoride. Materials and Methods: NiTi corrosion resistance was investigated through electrochemical impedance spectroscopy and anodic polarization in sodium chloride (NaCl 0.15 M) with and without addition of 0.02 M sodium fluoride (NaF), and the results were compared with those associated with beta titanium. The influence of fluoride concentration on NiTi corrosion behavior was assessed in NaCl (0.15 M) with and without 0.02, 0.04, 0.05, 0.07, and 0.12 M NaF solution. Galvanic corrosion between NiTi and beta titanium were investigated. All samples were characterized by scanning electron microscopy. Results: Polarization resistance decreased when NaF concentration was increased, and, depending on NaF concentration, NiTi can suffer localized or generalized corrosion. In NaCl solution with 0.02 M NaF, NiTi suffer localized corrosion, while beta titanium alloys remained passive. Current values near zero were observed by galvanic coupling of NiTi and beta titanium. Conclusions: There is a decrease in NiTi corrosion resistance in the presence of fluoride. The corrosion behavior of NiTi alloy depends on fluoride concentration. When 0.02 and 0.04 M of NaF were added to the NaCl solution, NiTi presented localized corrosion. When NaF concentration increased to 0.05, 0.07, and 0.12 M, the alloy presented general corrosion. NiTi corrosion resistance behavior is lower than that of beta titanium. Galvanic coupling of these alloys does not increase corrosion rates.


2011 ◽  
Vol 194-196 ◽  
pp. 1253-1256
Author(s):  
Ya Ni Zhang ◽  
Mao Sheng Zheng ◽  
Jie Wu Zhu

The corrosion behavior of CuCr, CuZr and CuCrZr alloys in NaCl solution is reported in this paper. The corrosion performance has been evaluated in NaCl solution atmosphere. The results show the corrosion resistance of pure copper decrease with the addition of the alloying elements initially. However, in the later exposure stages, the corrosion resistance of CuZr and CuCrZr alloy deteriorates significantly while the corrosion resistance of CuCr alloy is slightly better than that of pure copper. In addition, the results of the electrochemical experiments indicate that the different behavior for the element Cr and Zr in the base material and corrosion scales lead to the change of the corrosion resistance.


2013 ◽  
Vol 803 ◽  
pp. 226-229
Author(s):  
Da Ran Fang ◽  
Chun Liu ◽  
Feng Fang Liu

Al-3.9wt.%Cu alloy was subjected to equal channel angular pressing (ECAP) and subsequent low temperature annealing treatment, and the corrosion resistance of the samples was investigated by potentiodynamic polarization measurements in 3.5% NaCl solution. The results show that the corrosion rate of the ultrafine-grained alloy increases, in comparison with the coarse-grained alloy. Meanwhile, it is noted that the corrosion resistance of the alloy subjected to ECAP can be improved by relief annealing.


2011 ◽  
Vol 55-57 ◽  
pp. 378-381
Author(s):  
Li Hua Pan ◽  
Rui Cheng Yang

The corrosion resistance of Ni-Cr-Mo-Cu alloys designed by formula APF=4Cr/(2Mo+Cu) to aqueous depend on the APF is investigated. The cathodic current of corrosion reactions was expressed as the quantum electrochemical equation. It is discussed that the APF controls the corrosion resistance to aqueous.


Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 566
Author(s):  
Pham Hong Quan ◽  
Iulian Antoniac ◽  
Florin Miculescu ◽  
Aurora Antoniac ◽  
Veronica Manescu (Păltânea) ◽  
...  

Fluoride conversion coatings on Mg present many advantages, among which one can find the reduction of the corrosion rate under “in vivo” or “in vitro” conditions and the promotion of the calcium phosphate deposition. Moreover, the fluoride ions released from MgF2 do not present cytotoxic effects and inhibit the biofilm formation, and thus these treated alloys are very suitable for cardiovascular stents and biodegradable orthopedic implants. In this paper, the biodegradation behavior of four new magnesium biodegradable alloys that have been developed in the laboratory conditions, before and after surface modifications by fluoride conversion (and sandblasting) coatings, are analyzed. We performed structural and surface analysis (XRD, SEM, contact angle) before and after applying different surface treatments. Furthermore, we studied the electrochemical behavior and biodegradation of all experimental samples after immersion test performed in NaCl solution. For a better evaluation, we also used LM and SEM for evaluation of the corroded samples after immersion test. The results showed an improved corrosion resistance for HF treated alloy in the NaCl solution. The chemical composition, uniformity, thickness and stability of the layers generated on the surface of the alloys significantly influence their corrosion behavior. Our study reveals that HF treatment is a beneficial way to improve the biofunctional properties required for the studied magnesium alloys to be used as biomaterials for manufacturing the orthopedic implants.


2018 ◽  
Vol 913 ◽  
pp. 439-444 ◽  
Author(s):  
Zhao Ming Li ◽  
Hai Chang Jiang ◽  
Yun Li Wang ◽  
Duo Zhang ◽  
De Sheng Yan ◽  
...  

In this paper, the effect of Sc addition (0.06 wt%) on the corrosion behavior of medium strength Al-Zn-Mg alloy is investigated by mass loss measurements, electrochemical experiment, intergranular corrosion and exfoliation corrosion tests. The results indicate the addition of Sc reduces the relative weight loss and enhances pitting performance as a result of grain refinement. The improved intergranular corrosion and exfoliation corrosion resistance caused by minor Sc addition are mainly attributed to the delay in both the initiation and advance stages of local corrosion.


Author(s):  
Jie Teng ◽  
Zili Xu ◽  
Jinlong Su ◽  
Yuan Li

Abstract In this study, hydroxyapatite-reinforced ZK60 Mg alloybased composites were fabricated via a powder metallurgy route. The mechanical properties of these composites were studied by compressive tests and hardness tests. The in-vitro corrosion behavior was also investigated using immersion testing and electrochemical measurement. The influence of hydroxyapatite content on the mechanical properties and invitro corrosion behavior was evaluated. The microstructure and corrosion morphology were characterized by means of X-ray diffraction, optical and scanning electron microscopy. The results showed that the composite materials with 10 wt.% hydroxyapatite exhibited a better combination of mechanical strength and corrosion resistance. Compared with ZK60 alloy, the addition of 10 wt.% hydroxyapatite resulted in an increase in corrosion resistance by 38.6%.


1970 ◽  
Vol 25 ◽  
pp. 53-61
Author(s):  
Minu Basnet ◽  
Jagadeesh Bhattarai

The corrosion behavior of the sputter-deposited nanocrystalline W-Cr alloys wasstudied in 0.5 M NaCl and alkaline 1 M NaOH solutions at 25°C, open to air usingimmersion tests and electrochemical measurements. Chromium metal acts synergisticallywith tungsten in enhancing the corrosion resistance of the sputter-deposited W-Cr alloys soas to show higher corrosion resistance than those of alloy-constituting elements in both 0.5M NaCl and 1 M NaOH solutions. In particular, the nanocrystalline W-Cr alloys containing25-91 at% chromium showed about one order of magnitude lower corrosion rates (that is,about 1-2 × 10-3 mm.y-1) than those of tungsten and chromium metals even for prolongedimmersion in 0.5 M NaCl solution at 25°C. On the other hand, the corrosion rate of thesputter-deposited W-Cr alloys containing 25-75 at % chromium was decreased significantlywith increasing chromium content and showed lowest corrosion rates (that is, 1.5-2.0 × 10-3 mm.y-1) after immersed for prolonged immersion in 1 M NaOH solution. The corrosion ratesof these nanocrystalline W-(25-75)Cr alloys are nearly two orders of magnitude lower thanthat of tungsten and more than one order of magnitude lower corrosion rate than that ofsputter-deposited chromium metal in 1 M NaOH solution. The corrosion-resistant of all theexamined sputter-deposited W-Cr alloys in 0.5 M NaCl solution is higher than in alkaline 1M NaOH solution at 25°C. Open circuit potentials of all the examined W-Cr alloys areshifted to more noble direction with increasing the chromium content in the alloys afterimmersion for 72 h in both 0.5 M NaCl and 1 M NaOH solutions at 25°C, open to air.Keywords: Sputter deposition, nanocrystalline W-Cr alloys, corrosion test, electrochemicalmeasurement, NaCl and NaOH solutions.DOI:  10.3126/jncs.v25i0.3300Journal of Nepal Chemical Society Volume 25, 2010 pp 53-61


Sign in / Sign up

Export Citation Format

Share Document