Chilled Coil Performance Control and Application to Turbine Inlet air Cooling

Author(s):  
Gopalakrishnan Anand ◽  
Ellen Makar
2021 ◽  
Vol 29 (01) ◽  
pp. 2150006
Author(s):  
Gopalakrishnan Anand ◽  
Ellen Makar

A Turbine Inlet Air Conditioning (TIAC) system can chill the inlet air of the turbine to maintain maximum turbine performance at all ambient temperatures. However, turbine characteristics, performance guarantees and bell-mouth icing considerations require accurate prediction of the chilling coil performance over a wide range of operating conditions. A modified wet-surface model (MWSM) is developed to more accurately predict the chilling coil performance. The higher accuracy of the model is demonstrated by applying the model to simulate performance data of two different coils. The data covered a wide range of operating conditions with ambient temperature vary from [Formula: see text]C to [Formula: see text]C dry bulb and [Formula: see text]C to [Formula: see text]C wet bulb. The turbine flow rate varies from 100% to 43% with chilled air temperature in the range of 3.3–[Formula: see text]C and chilling load variation of 100% to 5%. The chilled water flow rate varies from 100% to 32% with supply glycol-water temperature in the range of [Formula: see text]2.2–[Formula: see text]C. The MWSM uses 11 empirical parameters evaluated from the coil performance data and is able to correlate the data with an adjusted coefficient of determination ([Formula: see text]) of over 99%. The higher accuracy of the modified model enables the development of a more robust controls strategy required to maintain the inlet air temperature at the set point with varying ambient temperatures and chilling load conditions. The model can also be applied to other chilling and dehumidification applications especially those experiencing wide variations in operating conditions and load or those requiring close control of the chilling and dehumidification process.


1967 ◽  
Vol 89 (1) ◽  
pp. 41-46 ◽  
Author(s):  
N. E. Starkey

Design considerations required for base load long-life service at turbine inlet temperature above 1600 F are discussed. These include control of combustion profile, air cooling of the first-stage nozzle, long-shank turbine buckets, accurate air and fuel distribution, and accurate temperature control.


Author(s):  
Gopalakrishnan Anand ◽  
Ellen Makar

Ambient conditions greatly affect the combustion turbine performance. The Absorption Refrigeration Cycle Turbine Inlet Chilling (ARCTIC) system can chill the inlet air of the turbine to maintain optimum performance at all ambient temperatures. However, turbine characteristics, bell-mouth icing concerns, economics and performance guarantees require maintaining the inlet air temperature within a narrow range throughout the year. These considerations require strict control of the Turbine Inlet Air Chilling (TIAC) coil performance over a wide range of operating conditions. This paper describes the field performance and control of the chilling coil for a Mars 100 turbine. The controls logic had been developed from previously published empirical model of the chilling coil and model of the chilling loop performance at the various ambient conditions. Since commissioning at the end of summer 2020, the ARCTIC has provided inlet air chilling over a range of ambient conditions. Typically, the inlet air is maintained at 7.2∘C (45∘F) by controlling the TIAC chilled water flow rate and temperature. On cooler days, if the inlet air temperature drops to 5.6∘C (42∘F) the chilled water pump turns OFF automatically to prevent bell-mouth icing. Thus, the chiller accommodates chilling load variations down to zero load. On colder days, the ARCTIC continues operating till the ambient temperature drops below 1.7∘C (35∘F) and then turns OFF. The chiller turns back ON when the 8 h average inlet air temperature exceeds 10∘C (50∘F). These parameters can be adjusted remotely by the operator and help maintain performance guarantees while minimizing chiller cycling. Quasi-steady state data were analyzed to quantify the chilling load and coil performance over a range of operating conditions.


2007 ◽  
Vol 31 (13) ◽  
pp. 1292-1306 ◽  
Author(s):  
Galal M. Zaki ◽  
Rahim K. Jassim ◽  
Majed M. Alhazmy

Author(s):  
Hany A. Al-Ansary

Cooling turbine inlet air is a proven method of increasing turbine power output, especially during peak summer demand. It is estimated that turbine power output can increase by as much as 0.7% for every 1°C drop in inlet air temperature. Two inlet air cooling systems are widely used: evaporative cooling systems and chiller systems. Evaporative cooling is economical and uncomplicated, but its efficiency can significantly drop if the relative humidity is high. There is also a potential for excessive wear of compressor blades if water droplets are carried into the compressor section. On the other hand, chiller systems have the advantage of being independent of humidity and do not have the potential to cause damage to compressor blades. However, chiller systems consume power and cause a larger pressure drop than evaporative coolers. In this work, the possibility of using an ejector refrigeration system to cool turbine inlet air is explored. These systems are low-maintenance, fluid-driven, heat-operated devices that can use part of the turbine exhaust flow as the heat source for running the cycle. These systems require only pump power to feed liquid refrigerant to the vapor generator, making the power consumption potentially lower than conventional chiller systems. Using thermodynamic analysis, this paper compares the performance of ejector refrigeration systems with that of chiller systems based primarily on their power consumption. Performance characteristics for the ejector system are obtained through a CFD model that uses a real-gas model for R-134a. Published data on the performance of a commercial gas turbine is also considered. The power consumption of ejector refrigeration systems is found to be significantly smaller than that of vapor compression systems, with savings ranging from 19% to 80%. Power consumption is also found to be small compared to the boost in turbine power that is obtained. The percentage of waste heat needed to operate the ejector refrigeration system is found to be generally less than 25%.


2013 ◽  
Vol 75 ◽  
pp. 214-223 ◽  
Author(s):  
Hany A. Al-Ansary ◽  
Jamel A. Orfi ◽  
Mohamed E. Ali

Author(s):  
Sandu Constantin ◽  
Dan Brasoveanu

Abstract The thermal efficiency of gas turbines is critically dependent on the temperature of burnt gases at turbine inlet, the higher this temperature the higher the efficiency. Stochiometric combustion would provide maximum efficiency, but in the absence of an internal cooling system, turbine blades cannot tolerate gas temperatures that exceed 1300 K. Therefore, for this temperature, the thermal efficiency of turbine engine is 40% less than theoretical maximum. Conventional air-cooling techniques of turbine blades allow inlet temperatures of about 1500 K on current operating engines yielding thermal efficiency gains of about 6%. New designs, that incorporate advanced air-cooling methods allows inlet temperatures of 1750–1800 K, with a thermal efficiency gain of about 6% relative to current operating engines. This temperature is near the limit allowed by air-cooling systems. Turbine blades can be cooled with air taken from the compressor or with liquid. Cooling systems with air are easier to design but have a relatively low heat transfer capacity and reduce the efficiency of the engine. Some cooling systems with liquid rely on thermal gradients to promote re-circulation from the tip to the root of turbine blades. In this case, the flow and cooling of liquid are restricted. For best results, cooling systems with liquid should use a pump to re-circulate the coolant. In the past, designers tried to place this pump on the engine stator and therefore were unable to avoid high coolant losses because it is impossible to reliably seal the stator-rotor interface. Therefore it was assumed that cooling systems with liquid could not incorporate pumps. This is an unwarranted assumption as shown studying the system in a moving frame of reference that is linked to the rotor. Here is the crucial fact overlooked by previous designers. The relative motion of engine stator with respect to the rotor is sufficient to motivate a cooling pump. Both the pump and heat exchange system that is required to provide rapid cooling of liquid with cold ambient air, could be located within the rotor. Therefore, the entire cooling system can be encapsulated within the rotor and the sealing problem is circumvented. Compared to recent designs that use advanced air-cooling methods, such a liquid cooling system would increase the thermal efficiency by 8%–11% because the temperatures at turbine inlet can reach stoichiometric levels and most of the heat extracted from turbine during cooling is recuperated. The appreciated high reliability of the system will permit a large applicability in aerospace propulsion.


Author(s):  
John Confurius

The profits that can be gained by use of inlet air cooling on gas turbines has been recognised for quite some time now and the systems installed throughout the world have shown the users in the gas turbine field that cooling indeed can be used to boost power at times when the ambient temperature reaches or exceeds the ISO rating temperature of the gas turbine. Drawback however being that the initial investment asked of the gas turbine user is rather large thus only justifying a cooling system in regions where the outdoor temperatures exceed the ISO rating time and again due to the climate in that region. Lately gas turbine users in colder climates have become interested in power augmentation during their short summer, however there is no justification for an investment like necessary when installing one of the presently available systems on the market. As the question reached us from more and more of our clients it stimulated us to go out and search for a low-investment solution to this problem. This resulted in the world’s first low pressure gas turbine inlet cooling system.


Author(s):  
A Nordin ◽  
D A Salim ◽  
M A Othoman ◽  
S N Omar Kamal ◽  
Danny Tam ◽  
...  

Sign in / Sign up