Cocaine and exercise: temporal changes in plasma levels of catecholamines, lactate, glucose, and cocaine

1996 ◽  
Vol 270 (3) ◽  
pp. E438-E444 ◽  
Author(s):  
D. H. Han ◽  
K. P. Kelly ◽  
G. W. Fellingham ◽  
R. K. Conlee

To determine the combined sympathoadrenal effects of cocaine and exercise in awake animals, rats were assigned to one of four treatment groups: saline-rest (SR), saline-exercise (SE), cocaine-rest (CR), and cocaine-exercise (CE). Venous blood samples from jugular catheters were obtained at -40, 0-4, 7, 10, 13, 16, 19, 26, and 36 min after intravenous injection of cocaine (5 mg/kg) or saline and the simultaneous onset of a 16-min treadmill run (26 m/min, 10% grade). CE increased plasma epinephrine (24.2 nM at 16 min), norepinephrine (28.0 nM at 10 min), and lactate (11.2 mM at 4 min) to levels 2-5 times greater than either treatment (SE and CR) alone (P<0.05) and 11-35 times higher that SR. Blood glucose values were significantly depressed in CE (-33% vs. SE) but increased in CR (+26% vs. SR). Plasma cocaine peaked < 2 min after injection in both CR and CE, and the peak was 69% higher in CE (P<0.05); however, the plasma elimination half-life (12-14 min) was not different. These results indicate that the combined effect of the two sympathoadrenal stimulants, exercise and cocaine, amplify the catecholamine responses to levels far greater than when each stimulant is used alone.

2021 ◽  
pp. 105477382110247
Author(s):  
Eda Ergin ◽  
Ayten Zaybak

The purpose of this study is to compare whether or not there is a difference between venous and capillary blood samples in blood glucose measurements and investigate the effects of different aseptic methods used in skin cleaning before collecting blood samples on measurement results. This quasi-experimental study was conducted with 109 patients. The capillary first and second blood drop values taken from the patients after fasting and at 2 hours following 75 g oral glucose tolerance test (OGTT) and capillary and venous blood glucose values were compared. There was no significant difference between the median venous blood glucose value and the capillary second blood drop value taken after wiping the finger with alcohol. There was no significant difference between the first and second blood drop values of capillary blood glucose 2 hours after OGTT.


2021 ◽  
Vol 14 (2) ◽  
pp. 119
Author(s):  
Ruben A. G. van Eerden ◽  
Esther Oomen-de Hoop ◽  
Aad Noordam ◽  
Ron H. J. Mathijssen ◽  
Stijn L. W. Koolen

Small molecule kinase inhibitors (SMKIs) are widely used in oncology. Therapeutic drug monitoring (TDM) for SMKIs could reduce underexposure or overexposure. However, logistical issues such as timing of blood withdrawals hamper its implementation into clinical practice. Extrapolating a random concentration to a trough concentration using the elimination half-life could be a simple and easy way to overcome this problem. In our study plasma concentrations observed during 24 h blood sampling were used for extrapolation to trough levels. The objective was to demonstrate that extrapolation of randomly taken blood samples will lead to equivalent estimated trough samples compared to measured Cmin values. In total 2241 blood samples were analyzed. The estimated Ctrough levels of afatinib and sunitinib fulfilled the equivalence criteria if the samples were drawn after Tmax. The calculated Ctrough levels of erlotinib, imatinib and sorafenib met the equivalence criteria if they were taken, respectively, 12 h, 3 h and 10 h after drug intake. For regorafenib extrapolation was not feasible. In conclusion, extrapolation of randomly taken drug concentrations to a trough concentration using the mean elimination half-life is feasible for multiple SMKIs. Therefore, this simple method could positively contribute to the implementation of TDM in oncology.


Author(s):  
I. W. Percy-Robb ◽  
R. S. McMaster ◽  
A. D. B. Harrower ◽  
L. J. P. Duncan

The ‘Dextrostix’-reflectance meter system for blood glucose analysis has been evaluated using a blood glucose reference method. A high degree of concordance between the two methods was obtained when analyses were performed by skilled laboratory staff on venous blood samples containing fluoride, with a 75 s contact time. Skilled laboratory staff performed significantly better than unskilled staff. Capillary blood glucose concentrations correlated poorly with concentrations in venous blood samples taken at the same time as the capillary blood.


Author(s):  
Li-Nong Ji ◽  
Li-Xin Guo ◽  
Li-Bin Liu

AbstractBlood glucose self-monitoring by individuals with diabetes is essential in controlling blood glucose levels. The International Organization for Standardization (ISO) introduced new standards for blood glucose monitoring systems (BGMS) in 2013 (ISO 15197: 2013). The CONTOUR PLUSThis study evaluated the accuracy and precision of CONTOUR PLUS BGMS in quantitative glucose testing of capillary and venous whole blood samples obtained from 363 patients at three different hospitals.Results of fingertip and venous blood glucose measurements by the CONTOUR PLUS system were compared with laboratory reference values to determine accuracy. Accuracy was 98.1% (96.06%–99.22%) for fingertip blood tests and 98.1% (96.02%–99.21%) for venous blood tests. Precision was evaluated across a wide range of blood glucose values (5.1–17.2 mmol/L), testing three blood samples repeatedly 15 times with the CONTOUR PLUS blood glucose meter using test strips from three lots. All within-lot results met ISO criteria (i.e., SD<0.42 mmol/L for blood glucose concentration <5.55 mmol/L; CV<7.5% for blood glucose concentration ≥5.55 mmol/L). Between-lot variations were 1.5% for low blood glucose concentration, 2.4% for normal and 3.4% for high.Accuracy of both fingertip and venous blood glucose measurements by the CONTOUR PLUS system was >95%, confirming that the system meets ISO 15197: 2013 requirements.


1989 ◽  
Vol 123 (2) ◽  
pp. 173-179 ◽  
Author(s):  
B. K. Campbell ◽  
A. S. McNeilly ◽  
D. T. Baird

ABSTRACT In sheep, secretion of oestradiol by the ovary is stimulated by pulses of LH but the factors controlling ovarian inhibin secretion are not well understood. We have investigated the effect of a single injection of LH on the ovarian secretion of inhibin. Six anoestrous Finn–Merino ewes which had one ovary autotransplanted to a site in the neck had jugular and timed ovarian venous blood samples collected at 10-min intervals for a total of 5 h. The secretion rates of both inhibin (1–3 ng/min) and oestradiol (0·5–8 ng/min) were similar to those observed during the breeding season indicating significant follicular development in these animals. After injection of 2·5 μg NIH-LH-S25 intravenously the concentration of LH in plasma rose from a baseline of 1·8 ±0·1 (s.e.m.) μg/l to a peak of 3·9 ±0·3 μg/l (P<0·01). This LH pulse stimulated a corresponding increase (P<0·01) in oestradiol secretion from a basal level of 0·9±0·2 ng/min to a peak of 4·6±0·6 ng/min that occurred within 30 min of injection. Although inhibin secretion was episodic in nature, increases were not related to either exogenous or endogenous LH pulses. We conclude that, in contrast to oestradiol, the secretion of inhibin by the ovary is not controlled acutely by changes in plasma levels of LH during anoestrus. Journal of Endocrinology (1989) 123, 173–179


2006 ◽  
Vol 291 (4) ◽  
pp. G611-G620 ◽  
Author(s):  
Lixin Wang ◽  
Nicole R. Basa ◽  
Almaas Shaikh ◽  
Andrew Luckey ◽  
David Heber ◽  
...  

LPS injected intraperitoneally decreases fasted plasma levels of ghrelin at 3 h postinjection in rats. We characterized the inhibitory action of LPS on plasma ghrelin and whether exogenous ghrelin restores LPS-induced suppression of food intake and gastric emptying in fasted rats. Plasma ghrelin and insulin and blood glucose were measured after intraperitoneal injection of LPS, intravenous injection of IL-1β and urocortin 1, and in response to LPS under conditions of blockade of IL-1 or CRF receptors by subcutaneous injection of IL-1 receptor antagonist (IL-1Ra) or astressin B, respectively, and prostaglandin (PG) synthesis by intraperitoneal indomethacin. Food intake and gastric emptying were measured after intravenous injection of ghrelin at 5 h postintraperitoneal LPS injection. LPS inhibited the elevated fasted plasma ghrelin levels by 47.6 ± 4.9%, 58.9 ± 3.3%, 74.4 ± 2.7%, and 48.9 ± 8.7% at 2, 3, 5, and 7 h postinjection, respectively, and values returned to preinjection levels at 24 h. Insulin levels were negatively correlated to those of ghrelin, whereas there was no significant correlation between glucose and ghrelin. IL-1Ra and indomethacin prevented the first 3-h decline in ghrelin levels induced by LPS, whereas astressin B did not. IL-1β inhibited plasma ghrelin levels, whereas urocortin 1 had no influence. Ghrelin injected intravenously prevented an LPS-induced 87% reduction of gastric emptying and 61% reduction of food intake. These data showed that IL-1 and PG pathways are part of the early mechanisms by which LPS suppresses fasted plasma ghrelin and that exogenous ghrelin can normalize LPS-induced-altered digestive functions.


2020 ◽  
Vol 58 (3) ◽  
pp. 445-455
Author(s):  
Annette Baumstark ◽  
Nina Jendrike ◽  
Ulrike Kamecke ◽  
Christina Liebing ◽  
Stefan Pleus ◽  
...  

AbstractBackgroundThe professional-use systems HemoCue® Glucose 201+ (HC201+) and HemoCue® Glucose 201 RT (HC201RT) are widely used for point-of-care testing (POCT) of blood glucose (BG). HC201RT utilizes unit-use microcuvettes which can be stored at room temperature, whereas HC201+ microcuvettes have to be stored at <8 °C. In this study, system accuracy of HC201+ and HC201RT was evaluated using capillary and venous blood samples.MethodsFor each system, two reagent system lots were evaluated within a period of 2 years based on testing procedures of ISO 15197:2013, a standard applicable for self-monitoring of blood glucose (SMBG) systems. For each reagent system lot, the investigation was performed by using 100 capillary and 95 to 99 venous blood samples. Comparison measurements were performed with a hexokinase laboratory method. Accuracy criteria of ISO 15197:2013 and POCT12-A3 were applied. In addition, bias was analyzed according to Bland and Altman, and error grid analysis was performed.ResultsWhen measuring capillary samples, both systems fulfilled accuracy requirements of ISO 15197:2013 and POCT12-A3 with the investigated reagent system lots. When measuring venous samples, only HC201+ fulfilled these requirements. Bias between HC201+ and reference measurements was more consistent over venous and capillary samples and microcuvette lots than for HC201RT. Error grid analysis showed that clinical actions might have been different depending on which system was used.ConclusionsIn this study, HC201+ showed a high level of accuracy irrespective of the sample type (capillary or venous). In contrast, HC201RT measurement results were markedly affected by the type of sample.


2006 ◽  
Vol 50 (9) ◽  
pp. 2996-3002 ◽  
Author(s):  
P. Diz Dios ◽  
I. Tomás Carmona ◽  
J. Limeres Posse ◽  
J. Medina Henríquez ◽  
J. Fernández Feijoo ◽  
...  

ABSTRACT We evaluated the efficacies of oral prophylactic treatment with amoxicillin (AMX), clindamycin (CLI), and moxifloxacin (MXF) in the prevention of bacteremia following dental extractions (BDE). Two hundred twenty-one adults who required dental extractions under general anesthesia were randomly assigned to a control group, an AMX group, a CLI group, and an MXF group (the individuals in the drug treatment groups received 2 g, 600 mg, and 400 mg, respectively, 1 to 2 h before anesthesia induction). Venous blood samples were collected from each patient at the baseline and 30 s, 15 min, and 1 h after the dental extractions. The samples were inoculated into BACTEC Plus aerobic and anaerobic blood culture bottles and were processed in a BACTEC 9240 instrument. Subculture and the further identification of the isolated bacteria were performed by conventional microbiological techniques. The prevalences of BDE in the control group, AMX group, CLI group, and MXF group were 96, 46, 85, and 57%, respectively, at 30 s; 64, 11, 70, and 24%, respectively, at 15 min; and 20, 4, 22, and 7%, respectively, at 1 h. Streptococcus spp. were the most frequently identified bacteria in all groups (44 to 68%), with the lowest percentage being detected in the AMX group (44%). AMX and MXF prophylaxis showed high efficacies in reducing the prevalence and duration of BDE, but CLI prophylaxis was noneffective. As a consequence, MXF prophylaxis is a promising antibiotic alternative for the prevention of BDE when beta-lactams are not indicated.


Author(s):  
J.O. Wesongah ◽  
G.A. Murilla ◽  
J.K. Kibugu ◽  
T.W. Jones

years, but recently there have been reports of prophylaxis failure under natural conditions. In this study, use of the drug for prophylactic purpose against trypanosomosis in small ruminants was investigated. Forty-two sheep and 44 goats were divided into four treatment groups. Groups 1 and 2 were treated with isometamidium chloride (Samorin(R), Rhone Merieux, Lyon, France) at 3-month intervals while groups 3 and 4 were used as controls. All the animals were exposed to natural tsetse challenge and monitored for serum isometamidium levels and anti-trypanosome antibodies. Seven days after drug administration, isometamidium levels were significantly higher in goats 13.7 + 0.07 ng/mℓ than in sheep 6.2 + 0.06 ng/mℓ. However, the elimination half-life in the sheep was 14.2 + 0.92 days and was significantly higher (P > 0.05) than that of the goats 12 + 0.5 days. This study established that isometamidium metabolism differs between sheep and goats and this difference may have important implications in high tsetse challenge areas.


2017 ◽  
Vol 28 (4) ◽  
pp. 436-455 ◽  
Author(s):  
Tulay Sagkal Midilli ◽  
Eda Ergın ◽  
Ebru Baysal ◽  
Zeki Arı

The purpose of the study was to determine differences and correlations between the blood glucose values of venous blood and the first and second drops of capillary blood samples taken in three different ways. Blood samples were (a) venous blood, (b) the first and second drops of capillary blood from the middle finger of the right hand (only washed with soap and water), and (c) the first and second drops of capillary blood from the middle finger of the left hand (washed with soap and water and cleaned with alcohol). It was concluded that the fasting capillary blood glucose values could be used in place of venous blood glucose values, that only washing the hands with neutral soap and water for 30 s could be sufficient for capillary blood glucose measurement, and that the first or second blood drop from a clean hand could be used for capillary blood glucose measurement.


Sign in / Sign up

Export Citation Format

Share Document