Endothelial regulation of wall shear stress and blood flow in skeletal muscle microcirculation

1991 ◽  
Vol 260 (3) ◽  
pp. H862-H868 ◽  
Author(s):  
A. Koller ◽  
G. Kaley

In the presence of intact endothelium, in control conditions, calculated wall shear rate (WSR) (means +/- SE: 2,658 +/- 123 s-1; n = 21) was independent of arteriolar diameter (16.2-27.2 microns; correlation coefficient: r = 0.12, P greater than 0.05) in cremaster muscle of pentobarbital-anesthetized rats. An increase in blood flow velocity (due to parallel arteriolar occlusion) elicited a significant increase in WSR (to 4,981 +/- 253 s-1) followed by a delayed (6-15 s) increase in diameter (from: 22.5 +/- 0.6 to 29.5 +/- 0.8 microns), which consequently resulted in a significant decrease in WSR (to 3,879 +/- 203 s-1). As a result of the increased flow velocity and dilation, calculated arteriolar blood flow increased by 230%. After impairment of the endothelium of arterioles by a light-dye technique, basal WSR became significantly higher (3,604 +/- 341 s-1), and despite a greater increase in WSR (10,360 +/- 1,471 s-1) the dilation was absent. Now an inverse linear correlation was found between arteriolar diameter and WSR both before (r = 0.58, P less than 0.05) and during increased flow velocity conditions (r = 0.85, P less than 0.05). Also, arteriolar blood flow that was already less after impairment of endothelium increased by only 66% during the period of increased flow velocity due to the absence of dilation. Results suggest that an increase in wall shear stress is the stimulus for the endothelium-dependent mechanism that elicits "flow dependent" arteriolar dilation.(ABSTRACT TRUNCATED AT 250 WORDS)

1990 ◽  
Vol 258 (3) ◽  
pp. H916-H920 ◽  
Author(s):  
A. Koller ◽  
G. Kaley

In rat cremaster muscle, utilizing parallel arteriolar occlusion, we found that an increase in red blood cell (RBC) velocity (3.5-26.5 mm/s) per se induced an increase in diameter (1.5-9.4 microns) of arterioles (mean control diam 21.5 +/- 0.6 microns; n = 25). The dilation of arterioles appeared only when RBC velocity increased and started always with a delay (mean 8.4 +/- 0.5 s) after the increase in flow velocity. A positive linear correlation was found between peak changes in RBC velocity and diameter (r = 0.87, P less than 0.05). The velocity sensor as well as the mechanism(s) that mediates this response is likely to be located in endothelial cells, because the dilation to increased RBC velocity was completely eliminated after impairment of arteriolar endothelium with light-dye (L-D) treatment. The in vivo demonstration of this phenomenon in arterioles suggests the existence of a new endothelium-dependent, flow velocity-sensitive mechanism for the regulation of blood flow in the microcirculation.


PLoS ONE ◽  
2016 ◽  
Vol 11 (4) ◽  
pp. e0152873 ◽  
Author(s):  
Mary Hammes ◽  
Michael Boghosian ◽  
Kevin Cassel ◽  
Sydeaka Watson ◽  
Brian Funaki ◽  
...  

2015 ◽  
Vol 43 (1) ◽  
pp. 236-248 ◽  
Author(s):  
Pim van Ooij ◽  
Alexander L. Powell ◽  
Wouter V. Potters ◽  
James C. Carr ◽  
Michael Markl ◽  
...  

2020 ◽  
Vol 59 (SK) ◽  
pp. SKKE16 ◽  
Author(s):  
Ryo Nagaoka ◽  
Kazuma Ishikawa ◽  
Michiya Mozumi ◽  
Magnus Cinthio ◽  
Hideyuki Hasegawa

2021 ◽  
Author(s):  
Chandan Kumawat ◽  
Bhupendra Kumar Sharma ◽  
Khalid Saad Mekheimer

Abstract A two-phase blood flow model is considered to analyze the fluid flow and heat transfer in a curved tube with time-variant stenosis. In both core and plasma regions, the variable viscosity model ( Hematocrit and non linear temperature-dependent, respectively) is considered. A toroidal coordinate system is considered to describe the governing equations. The perturbation technique in terms of perturbation parameter ε is used to obtain the temperature profile of blood flow. In order to find the velocity, wall shear stress and impedance profiles, a second-order finite difference method is employed with the accuracy of 10−6 in the each iteration. Under the conditions of fully-developed flow and mild stenosis, the significance of various physical parameters on the blood velocity, temperature, wall shear stress (WSS) and impedance are investigated with the help of graphs. A validation of our results has been presented and comparison has been made with the previously published work and present study, and it revels the good agreement with published work. The present mathematical study suggested that arterial curvature increase the fear of deposition of plaque (atherosclerosis), while, the use of thermal radiation in heat therapies lowers this risk. The positive add in the value of λ1 causes to increase in plasma viscosity; as a result, blood flow velocity in the stenosed artery decreases due to the assumption of temperature-dependent viscosity of the plasma region. Clinical researchers and biologists can adopt the present mathematical study to lower the risk of lipid deposition, predict cardiovascular disease risk and current state of disease by understanding the symptomatic spectrum, and then diagnose patients based on the risk.


2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Mongkol Kaewbumrung ◽  
Somsak Orankitjaroen ◽  
Pichit Boonkrong ◽  
Buraskorn Nuntadilok ◽  
Benchawan Wiwatanapataphee

A mathematical model of dispersed bioparticle-blood flow through the stenosed coronary artery under the pulsatile boundary conditions is proposed. Blood is assumed to be an incompressible non-Newtonian fluid and its flow is considered as turbulence described by the Reynolds-averaged Navier-Stokes equations. Bioparticles are assumed to be spherical shape with the same density as blood, and their translation and rotational motions are governed by Newtonian equations. Impact of particle movement on the blood velocity, the pressure distribution, and the wall shear stress distribution in three different severity degrees of stenosis including 25%, 50%, and 75% are investigated through the numerical simulation using ANSYS 18.2. Increasing degree of stenosis severity results in higher values of the pressure drop and wall shear stresses. The higher level of bioparticle motion directly varies with the pressure drop and wall shear stress. The area of coronary artery with higher density of bioparticles also presents the higher wall shear stress.


Author(s):  
Florian von Knobelsdorff-Brenkenhoff ◽  
Achudhan Karunaharamoorthy ◽  
Ralf Felix Trauzeddel ◽  
Alex J. Barker ◽  
Edyta Blaszczyk ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document