Evaluation of alveolar amplitude response technique for determination of lung perfusion in exercise

1981 ◽  
Vol 50 (5) ◽  
pp. 1071-1078 ◽  
Author(s):  
S. C. Luijendijk ◽  
A. Zwart ◽  
A. M. van der Kooij ◽  
W. R. de Vries

We investigated the influence of tracer gas venous return on the determination of pulmonary perfusion (Qp) using the alveolar amplitude response technique (AART) to evaluate the applicability of this technique at rest and during exercise. The venous return influence was calculated by a computer simulation applied to a simplified body compartment model. Using the AART method, which neglects the influence of venous return, a simulation based on acetylene as a tracer gas predicted an overestimation of the actual value of Qp ranging from 0 to 10% for all work loads investigated. These theoretical results were compared with experimental results. Experiments with human subjects with acetylene as the tracer gas yielded an underestimation of Qp of about 20% at rest and an overestimation of about 7% under different exercise conditions. Experiments with anesthetized dogs showed an underestimation of Qp of about 12% for acetylene and about 6% for halothane. The theoretical and experimental results related to exercise conditions are thus in good quantitative agreement. The experimental data obtained for acetylene with human subjects at rest and with anesthetized dogs are also in good quantitative agreement. However, they deviate considerably from theoretical predictions. This discrepancy may be due to the simplified body compartment model used in the calculations, which can considerably influence the calculated results, especially for conditions at rest. The main conclusion of this paper is that recirculating tracer gas does not unduly influence results for Qp obtained with the AART method when halothane is used as the tracer gas.

1987 ◽  
Vol 42 (8) ◽  
pp. 808-812 ◽  
Author(s):  
A. Kawski ◽  
Z. Gryczyński

A formula is derived for the emission anisotropy r(β, Rs) of a polymer film as a function of the stretch ratio Rs of the film and of the angle β between the absorbing and emitting oscillators for the case when the long axis of the molecule makes an angle φ = 90° with the absorbing oscillator. This relation is verified, together with that obtained previously for φ = 0°, on the example of acridone and anthracene in polyvinyl alcohol. The experimental results obtained for r(β, Rs) as a function of Rs confirm the character of the predicted theoretical curves. The reasons for the lack of quantitative agreement is also discussed.


2020 ◽  
Vol 835 ◽  
pp. 229-242
Author(s):  
Oboso P. Bernard ◽  
Nagih M. Shaalan ◽  
Mohab Hossam ◽  
Mohsen A. Hassan

Accurate determination of piezoelectric properties such as piezoelectric charge coefficients (d33) is an essential step in the design process of sensors and actuators using piezoelectric effect. In this study, a cost-effective and accurate method based on dynamic loading technique was proposed to determine the piezoelectric charge coefficient d33. Finite element analysis (FEA) model was developed in order to estimate d33 and validate the obtained values with experimental results. The experiment was conducted on a piezoelectric disc with a known d33 value. The effect of measuring boundary conditions, substrate material properties and specimen geometry on measured d33 value were conducted. The experimental results reveal that the determined d33 coefficient by this technique is accurate as it falls within the manufactures tolerance specifications of PZT-5A piezoelectric film d33. Further, obtained simulation results on fibre reinforced and particle reinforced piezoelectric composite were found to be similar to those that have been obtained using more advanced techniques. FE-results showed that the measured d33 coefficients depend on measuring boundary condition, piezoelectric film thickness, and substrate material properties. This method was proved to be suitable for determination of d33 coefficient effectively for piezoelectric samples of any arbitrary geometry without compromising on the accuracy of measured d33.


2018 ◽  
Vol 233 ◽  
pp. 00025
Author(s):  
P.V. Polydoropoulou ◽  
K.I. Tserpes ◽  
Sp.G. Pantelakis ◽  
Ch.V. Katsiropoulos

In this work a multi-scale model simulating the effect of the dispersion, the waviness as well as the agglomerations of MWCNTs on the Young’s modulus of a polymer enhanced with 0.4% MWCNTs (v/v) has been developed. Representative Unit Cells (RUCs) have been employed for the determination of the homogenized elastic properties of the MWCNT/polymer. The elastic properties computed by the RUCs were assigned to the Finite Element (FE) model of a tension specimen which was used to predict the Young’s modulus of the enhanced material. Furthermore, a comparison with experimental results obtained by tensile testing according to ASTM 638 has been made. The results show a remarkable decrease of the Young’s modulus for the polymer enhanced with aligned MWCNTs due to the increase of the CNT agglomerations. On the other hand, slight differences on the Young’s modulus have been observed for the material enhanced with randomly-oriented MWCNTs by the increase of the MWCNTs agglomerations, which might be attributed to the low concentration of the MWCNTs into the polymer. Moreover, the increase of the MWCNTs waviness led to a significant decrease of the Young’s modulus of the polymer enhanced with aligned MWCNTs. The experimental results in terms of the Young’s modulus are predicted well by assuming a random dispersion of MWCNTs into the polymer.


1993 ◽  
Vol 16 (2) ◽  
pp. 63-70 ◽  
Author(s):  
N.A. Hoenich ◽  
P.T. Smirthwaite ◽  
C. Woffindin ◽  
P. Lancaster ◽  
T.H. Frost ◽  
...  

Recirculation is an important factor in single needle dialysis and, if high, can compromise treatment efficiency. To provide information regarding recirculation characteristics of access devices used in single needle dialysis, we have developed a new technique to characterise recirculation and have used this to measure the recirculation of a Terumo 15G fistula needle and a VasCath SC2300 single lumen catheter. The experimentally obtained results agreed well with those established clinically (8.5 ± 2.4% and 18.4 ± 3.4%). The experimental results have also demonstrated a dependence on access type, pump speeds and fistula flow rate. A comparison of experimental data with theoretical predictions showed that the latter exceeded those measured with the largest contribution being due to the experimental fistula.


1997 ◽  
Vol 273 (6) ◽  
pp. E1216-E1227 ◽  
Author(s):  
P. C. M. Van Zijl ◽  
D. Davis ◽  
S. M. Eleff ◽  
C. T. W. Moonen ◽  
R. J. Parker ◽  
...  

A new in vivo nuclear magnetic resonance (NMR) spectroscopy method is introduced that dynamically measures cerebral utilization of magnetically labeled [1-13C]glucose from the change in total brain glucose signals on infusion. Kinetic equations are derived using a four-compartment model incorporating glucose transport and phosphorylation. Brain extract data show that the glucose 6-phosphate concentration is negligible relative to glucose, simplifying the kinetics to three compartments and allowing direct determination of the glucose-utilization half-life time [ t ½ = ln2/( k 2 + k 3)] from the time dependence of the NMR signal. Results on isofluorane ( n = 5)- and halothane ( n = 7)- anesthetized cats give a hyperglycemic t ½ = 5.10 ± 0.11 min−1 (SE). Using Michaelis-Menten kinetics and an assumed half-saturation constant Kt = 5 ± 1 mM, we determined a maximal transport rate T max = 0.83 ± 0.19 μmol ⋅ g−1 ⋅ min−1, a cerebral metabolic rate of glucose CMRGlc = 0.22 ± 0.03 μmol ⋅ g−1 ⋅ min−1, and a normoglycemic cerebral influx rate CIRGlc = 0.37 ± 0.05 μmol ⋅ g−1 ⋅ min−1. Possible extension of this approach to positron emission tomography and proton NMR is discussed.


1983 ◽  
Vol 64 (2) ◽  
pp. 207-212 ◽  
Author(s):  
S. L. Grainger ◽  
P. W. N. Keeling ◽  
I. M. H. Brown ◽  
J. H. Marigold ◽  
R. P. H. Thompson

1. The disposition of an intravenous bolus of indocyanine green (ICG) has been studied in healthy man and baboons using a novel analysis of a two compartment pharmacokinetic model. 2. This analysis enabled the hepatic extraction ratio (ER) of dye to be determined solely from the plasma disappearance curve, and the ER determined did not differ from that measured by hepatic vein catheterization. 3. When compared with clearance measured at steady state, the two compartment model gave a significantly more accurate determination of plasma clearance than did the conventional one compartment model. 4. It is concluded that, in health, liver blood flow may be calculated accurately and noninvasively after a single intravenous injection of ICG.


2014 ◽  
Vol 698 ◽  
pp. 466-471
Author(s):  
Oleg V. Panchenko ◽  
Alexey M. Levchenko ◽  
Victor A. Karkhin

Specimens of various sizes are used to determine hydrogen content in deposited metals in such standards as ISO 3690, AWS A 4.3, and GOST 23338 while measuring methods are the same. It causes problems in comparison of experimental results and brings up the following question: what kind of specimen size is optimal to determine hydrogen content? An optimal specimen size was estimated using a calculation method. Experimental and calculation results obtained by using specimens with estimated dimensions were compared to the results obtained by using the specimen with dimensions of 100*25*8 mm to determine hydrogen content in a deposited metal.


2008 ◽  
Vol 608 ◽  
pp. 71-80 ◽  
Author(s):  
RODOLFO REPETTO ◽  
JENNIFER H. SIGGERS ◽  
ALESSANDRO STOCCHINO

We consider the flow in a spherical chamber undergoing periodic torsional oscillations about an axis through its centre, and analyse it both theoretically and experimentally. We calculate the flow in the limit of small-amplitude oscillations in the form of a series expansion in powers of the amplitude, finding that at second order, a steady streaming flow develops consisting of two toroidal cells. This streaming behaviour is also observed in our experiments. We find good quantitative agreement between theory and experiments, and we discuss the dependence of the steady streaming behaviour as both the oscillation frequency and amplitude are varied.


1973 ◽  
Vol 51 (6) ◽  
pp. 605-609 ◽  
Author(s):  
C. Boulet ◽  
N. Lacome ◽  
P. Isnard

From the analysis of the available experimental results, a vibrational dependence of N2O line widths is shown, which can be explained, applying the Anderson–Tsao–Curnutte theory. But no dependence on ν of any of the molecular parameters can be deduced. In the last part, we have pointed out the effect on the determination of the quadrupole moment of assuming a nonvanishing octupole moment for N2O.


Sign in / Sign up

Export Citation Format

Share Document