Effects of high-intensity sprint training on skeletal muscle blood flow in rats

1991 ◽  
Vol 71 (4) ◽  
pp. 1387-1395 ◽  
Author(s):  
T. I. Musch ◽  
J. A. Terrell ◽  
M. R. Hilty

The regional blood flow response (via radioactive microspheres) was determined for female rats after 6 wk of high-intensity sprint training (HIST) or limited cage activity as the animals exercised at work loads that would elicit maximal O2 uptake. Blood flow to the different organs of the abdominal region was greatly reduced during maximal exercise conditions, and the magnitude of the reduction appeared to be similar for both the HIST group of rats and their sedentary (SED) control counterparts. Of the 20 different hindlimb muscles examined in the present study, blood flow to the soleus, plantaris, gastrocnemius, flexor hallicus longus, vastus lateralis, rectus femoris, biceps femoris, and adductor magnus and brevis muscles was significantly greater (P less than 0.05) in the HIST rats during maximal exercise conditions than in the SED control rats. Correspondingly, blood flow to the total hindlimb during maximal exercise was also significantly greater in the HIST rats than in the SED control rats [240 +/- 18 vs. 192 +/- 15 (SE) ml.min-1.100 g-1]. These results support the contention that the increase in maximal cardiac output that is produced by HIST in the rat is primarily directed toward the working skeletal muscle and not toward the organs found in the abdominal region. We conclude from these experiments that HIST will produce significant adaptations in central cardiac function and skeletal muscle blood flow in the rat.

1980 ◽  
Vol 21 (Supplement) ◽  
pp. S84
Author(s):  
T. I. Musch ◽  
J. Terrell ◽  
L. Pletcher ◽  
J. Pisano ◽  
M. R. Hilty

1989 ◽  
Vol 21 (Supplement) ◽  
pp. S84
Author(s):  
T. I. Musch ◽  
J. Terrell ◽  
L. Pletcher ◽  
J. Pisano ◽  
M. R. Hilty

1995 ◽  
Vol 268 (2) ◽  
pp. R492-R497 ◽  
Author(s):  
C. H. Lang ◽  
M. Ajmal ◽  
A. G. Baillie

Intracerebroventricular injection of N-methyl-D-aspartate (NMDA) produces hyperglycemia and increases whole body glucose uptake. The purpose of the present study was to determine in rats which tissues are responsible for the elevated rate of glucose disposal. NMDA was injected intracerebroventricularly, and the glucose metabolic rate (Rg) was determined for individual tissues 20-60 min later using 2-deoxy-D-[U-14C]glucose. NMDA decreased Rg in skin, ileum, lung, and liver (30-35%) compared with time-matched control animals. In contrast, Rg in skeletal muscle and heart was increased 150-160%. This increased Rg was not due to an elevation in plasma insulin concentrations. In subsequent studies, the sciatic nerve in one leg was cut 4 h before injection of NMDA. NMDA increased Rg in the gastrocnemius (149%) and soleus (220%) in the innervated leg. However, Rg was not increased after NMDA in contralateral muscles from the denervated limb. Data from a third series of experiments indicated that the NMDA-induced increase in Rg by innervated muscle and its abolition in the denervated muscle were not due to changes in muscle blood flow. The results of the present study indicate that 1) central administration of NMDA increases whole body glucose uptake by preferentially stimulating glucose uptake by skeletal muscle, and 2) the enhanced glucose uptake by muscle is neurally mediated and independent of changes in either the plasma insulin concentration or regional blood flow.


2004 ◽  
Vol 97 (3) ◽  
pp. 1130-1137 ◽  
Author(s):  
Csongor Csekő ◽  
Zsolt Bagi ◽  
Akos Koller

We hypothesized that hydrogen peroxide (H2O2) has a role in the local regulation of skeletal muscle blood flow, thus significantly affecting the myogenic tone of arterioles. In our study, we investigated the effects of exogenous H2O2 on the diameter of isolated, pressurized (at 80 mmHg) rat gracilis skeletal muscle arterioles (diameter of ∼150 μm). Lower concentrations of H2O2 (10−6–3 × 10−5 M) elicited constrictions, whereas higher concentrations of H2O2 (6 × 10−5–3 × 10−4 M), after initial constrictions, caused dilations of arterioles (at 10−4 M H2O2, −19 ± 1% constriction and 66 ± 4% dilation). Endothelium removal reduced both constrictions (to −10 ± 1%) and dilations (to 33 ± 3%) due to H2O2. Constrictions due to H2O2 were completely abolished by indomethacin and the prostaglandin H2/thromboxane A2 (PGH2/TxA2) receptor antagonist SQ-29548. Dilations due to H2O2 were significantly reduced by inhibition of nitric oxide synthase (to 38 ± 7%) but were unaffected by clotrimazole or sulfaphenazole (inhibitors of cytochrome P-450 enzymes), indomethacin, or SQ-29548. In endothelium-denuded arterioles, clotrimazole had no effect, whereas H2O2-induced dilations were significantly reduced by charybdotoxin plus apamin, inhibitors of Ca2+-activated K+ channels (to 24 ± 3%), the selective blocker of ATP-sensitive K+ channels glybenclamide (to 14 ± 2%), and the nonselective K+-channel inhibitor tetrabutylammonium (to −1 ± 1%). Thus exogenous administration of H2O2 elicits 1) release of PGH2/TxA2 from both endothelium and smooth muscle, 2) release of nitric oxide from the endothelium, and 3) activation of K+ channels, such as Ca2+-activated and ATP-sensitive K+ channels in the smooth muscle resulting in biphasic changes of arteriolar diameter. Because H2O2 at low micromolar concentrations activates several intrinsic mechanisms, we suggest that H2O2 contributes to the local regulation of skeletal muscle blood flow in various physiological and pathophysiological conditions.


2013 ◽  
Vol 27 (S1) ◽  
Author(s):  
Zachary Barrett‐O'Keefe ◽  
Stephen J. Ives ◽  
Joel D. Trinity ◽  
Melissa A.H. Witman ◽  
Matthew J. Rossman ◽  
...  

2018 ◽  
Vol 1 (1) ◽  
Author(s):  
Ilkka Heinonen ◽  
Kari Kalliokoski ◽  
Vesa Oikonen ◽  
Christopher Mawhinney ◽  
Warren Gregson ◽  
...  

Objective Skeletal muscle is unique among organs in that its blood flow, thus oxygen supply that is critical for muscular function, can change over a remarkably large range. Compared to the rest, muscle blood flow can increase over 20-fold during intense exercise. Positron emission tomography (PET) and [15O]-H2O tracer provide a unique tool for the direct measurement of muscle blood flow in specific muscle regions. Quantification of PET blood flow requires knowledge of the arterial input function, which is usually provided by arterial blood sampling. However, arterial sampling is an invasive approach requiring arterial cannulation. In the current study, we aimed to explore the analysis and error estimation based on non-invasive, PET image-based input function for skeletal muscle blood flow in PET [15O]-labeled radiowater study. Methods Thirty healthy untrained men volunteered to participate in this study. [15O]-labeled radio water PET perfusion scans were performed at rest and right after cycling exercise. GE Discovery PET-CT scanner was used for image acquisition. The 15O isotope was produced with a Cyclone 3 cyclotron (IBA Molecular, Belgium). After 455 MBq of 15O-H2O was injected intravenously and after 20 seconds, dynamic scanning images were performed in following frames: 6x5 seconds, 12x10 seconds, 7x30 seconds and 12x10 seconds. Arterial blood was sampled continuously from radial artery during imaging for radioactivity with a detector during PET scanning. All the data analysis was performed using all in-house developed programs. Arterial input function was preprocessed with delay correction. Image-based input function was defined based on sum image of dynamic images. Blood flow was calculated using the 1-tissue compartment model, k1 is considered as blood flow without any further correction. All data analysis was performed by Carimas software (http://www.turkupetcentre.fi/carimas). Data analysis was performed in five parts: 1) Modelling data using input function from artery. 2) By defining femoral artery Volume Of Interest (VOI) on PET images. 3) Modelling data using image-based input function. 4) Calculating the correlation for blood flow between artery (blood) input function and image-based input function. 5) Predicted true blood flow was calculated based on correlation based on the initial linear relationship between blood and image-based input functions. Results Skeletal muscle blood flow had a good linear relationship calculated by femoral artery VOI and by arterial (blood) input function (y = 2,9587x - 0,096, R² = 0,8852, p<0.0001). Further, by using the prediction equation obtained by the linear relationship between VOI-determined (femoral) artery blood flow and direct gold standard (radial) artery input function determined blood flow, image-based input function determined blood flow was well predicted using this non-invasive approach (y = 1,1812x + 0,1219, R² = 0,9259, p<0.0001). Conclusions It is concluded that there is a strong linear correlation between gold standard invasive approach and non-invasive image-based approach to measure skeletal muscle blood flow by PET, but if no further corrections are made, image-based approach overestimates correct blood flow. However, this can be corrected by linear prediction equation, suggesting that invasive arterial input function may not always be needed in the future when measuring skeletal muscle blood flow by PET. This will be of benefit particularly for exercise studies.


Author(s):  
Miles F. Bartlett ◽  
Scott M. Jordan ◽  
Dennis M. Hueber ◽  
Michael D. Nelson

Near-infrared diffuse correlation spectroscopy (DCS) is increasingly utilized to study relative changes in skeletal muscle blood flow. However, most diffuse correlation spectrometers assume that tissue optical properties- such as absorption (μa) and reduced scattering (μ's) coefficients- remain constant during physiological provocations, which is untrue for skeletal muscle. Here, we interrogate how changes in tissue μa and μ's affect DCS calculations of blood flow index (BFI). We recalculated BFI using raw autocorrelation curves and μa/μ's values recorded during a reactive hyperemia protocol in 16 healthy young individuals. First, we show that incorrectly assuming baseline μa and μ's substantially affects peak BFI and BFI slope when expressed in absolute terms (cm2/s, p<0.01) but these differences are abolished when expressed in relative terms (% baseline). Next, to evaluate the impact of physiologic changes in μa and μ's, we compared peak BFI and BFI slope when μa and μ's were held constant throughout the reactive hyperemia protocol versus integrated from a 3s-rolling average. Regardless of approach, group means for peak BFI and BFI slope did not differ. Group means for peak BFI and BFI slope were also similar following ad absurdum analyses, where we simulated supraphysiologic changes in μa/μ's. In both cases, however, we identified individual cases where peak BFI and BFI slope were indeed affected, with this result being driven by relative changes in μa over μ's. Overall, these results provide support for past reports in which μa/μ's were held constant but also advocate for real-time incorporation of μa and μ's moving forward.


Sign in / Sign up

Export Citation Format

Share Document