The Evaluation of the PXQ for the Analysis of Cements and Related Materials

1958 ◽  
Vol 2 ◽  
pp. 215-227
Author(s):  
George Andermann ◽  
J. L. Jones ◽  
E. Davidson

AbstractThe analysis of cements and ores has been studied using the Applied Research Laboratories, Inc. Production Control X-ray Quantometer (PXQ), Elements included in the program were magnesium, aluminum, silicon, phosphorus, calcium and iron. The PXQ, utilizing the polychromator concept, allows the simultaneous determination of the listed elements.Focusing ADP, EDT, quartz and LiF crystals were used with flow Geigers or Multitrons. Helium paths were used as required. The choice of crystals, detectors, and slit widths was determined to give optimum results for each element.The effects of briquetting and ratioing to scattered background on accuracy were studied. Various instrumental factors such as helium flow rate, detector gas flow rate, short and long term stability were also investigated.

2011 ◽  
Vol 47 (2) ◽  
pp. 339-350 ◽  
Author(s):  
Raquel Nogueira ◽  
Eliane Cristina Pires do Rego ◽  
Marcus Vinicius Barreto Sousa ◽  
Wagner Wollinger ◽  
Thaís Elias da Silva ◽  
...  

This paper describes the studies performed with the candidate Certified Reference Material (CRM) of captopril, the first CRM of an active pharmaceutical ingredient (API) in Brazil, including determination of impurities (organic, inorganic and volatiles), homogeneity testing, short- and long-term stability studies, calculation of captopril content using the mass balance approach, and estimation of the associated measurement uncertainty.


Author(s):  
Allen Angel ◽  
Kathryn A. Jakes

Fabrics recovered from archaeological sites often are so badly degraded that fiber identification based on physical morphology is difficult. Although diagenetic changes may be viewed as destructive to factors necessary for the discernment of fiber information, changes occurring during any stage of a fiber's lifetime leave a record within the fiber's chemical and physical structure. These alterations may offer valuable clues to understanding the conditions of the fiber's growth, fiber preparation and fabric processing technology and conditions of burial or long term storage (1).Energy dispersive spectrometry has been reported to be suitable for determination of mordant treatment on historic fibers (2,3) and has been used to characterize metal wrapping of combination yarns (4,5). In this study, a technique is developed which provides fractured cross sections of fibers for x-ray analysis and elemental mapping. In addition, backscattered electron imaging (BSI) and energy dispersive x-ray microanalysis (EDS) are utilized to correlate elements to their distribution in fibers.


Mathematics ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 620
Author(s):  
Ioannis Kyriakou ◽  
Parastoo Mousavi ◽  
Jens Perch Nielsen ◽  
Michael Scholz

The fundamental interest of investors in econometric modeling for excess stock returns usually focuses either on short- or long-term predictions to individually reduce the investment risk. In this paper, we present a new and simple model that contemporaneously accounts for short- and long-term predictions. By combining the different horizons, we exploit the lower long-term variance to further reduce the short-term variance, which is susceptible to speculative exuberance. As a consequence, the long-term pension-saver avoids an over-conservative portfolio with implied potential upside reductions given their optimal risk appetite. Different combinations of short and long horizons as well as definitions of excess returns, for example, concerning the traditional short-term interest rate but also the inflation, are easily accommodated in our model.


Chemosensors ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 155
Author(s):  
Yan Su ◽  
Ting Liu ◽  
Caiqiao Song ◽  
Aiqiao Fan ◽  
Nan Zhu ◽  
...  

As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability.


1993 ◽  
Vol 98 (B3) ◽  
pp. 4619-4626 ◽  
Author(s):  
George Peter ◽  
Fred J. Klopping ◽  
Glenn S. Sasagawa ◽  
James E. Faller ◽  
Timothy M. Niebauer

2018 ◽  
Vol 86 (13) ◽  
pp. 301-314
Author(s):  
Maren Rastedt ◽  
Julian Büsselmann ◽  
Tomas Klicpera ◽  
Karsten Reinwald ◽  
Nadine Pilinski ◽  
...  

2014 ◽  
Vol 29 (4) ◽  
pp. 321-325
Author(s):  
Jovica Praskalo ◽  
Jasna Davidovic ◽  
Biljana Kocic ◽  
Monika Zivkovic ◽  
Svetlana Pejovic

In order to set up a successful mammography screening program in the Republic of Srpska, a Siemens Mammomat 1000 X-ray machine was selected for analysis as the said mammography system is widely used in clinical practice. The variations in tube parameters (specific air kerma, high-voltage accuracy and reproducibility, linearity between exposure and dose exposure time) were monitored over a five-year period, from 2008 to 2012. In addition, due to observed daily fluctuations for chosen parameters, a series of measurements were performed three times a day within a single-month period (mainly October 2012). The goal of such an experimental set up is to assess short-term and long-term stability of tube parameters in the given mammography unit and to make a comparison between them. The present paper shows how an early detection of significant parameter fluctuations can help eliminate irregularities and optimize the performance of mammography systems.