scholarly journals High-Temperature Furnaces for X-Ray Diffractometers

1961 ◽  
Vol 5 ◽  
pp. 169-190 ◽  
Author(s):  
William J. Campbell ◽  
Stephan Stecura ◽  
Clark Grain

AbstractThis paper summarizes developments in the field of high-temperature X-ray diffractometers through 1959, evaluates various furnace designs, and describes briefly the X-ray diffraction facilities of the Federal Bureau of Mines.X-ray optics, for those furnaces that have precision sample movements, are equivalent in resolution and line profile to conventional X-ray techniques. There is a 10-25% loss of intensity due to absorption of X-rays in the furnace windows, magnitude of which depends on wavelength and type of window used, and a reduction (5–40° 2θ) of useful angular range from limiting X-ray windows, radiation shielding, or the viewport for an optical pyrometer. In oxidizing atmospheres, temperatures up to 1500°C were obtained with furnaces wound with platinum—20% rhodium wire. Under nonoxidizing conditions temperatures of 1800 to 2000°C were obtained with both tantalum-foil and tungsten-wire heaters.Accurate temperature measurement over the area and depth of samples being studied is the most difficult problem in high-temperature X-ray diffractometry. Below 500°C, there are several furnace designs which are reported to reduce thermal differentials to less than 1°C across the sample. However, at temperatures around 1000°C, there are thermal gradients of 20-30°C/cm across the sample and 100–600°C/cm through the sample holder, making thermocouple location critical. Secondary standards have been used extensively to calibrate the furnaces; however, there is disagreement concerning which are the most reliable data to use. For these reasons, plus others discussed in this report, there is a probable error in the temperature determination of ±10 to 20°C at 1000°C, with the error increasing with temperature.

Crystals ◽  
2018 ◽  
Vol 8 (7) ◽  
pp. 273 ◽  
Author(s):  
José Brandão-Neto ◽  
Leonardo Bernasconi

Macromolecular crystallography at cryogenic temperatures has so far provided the majority of the experimental evidence that underpins the determination of the atomic structures of proteins and other biomolecular assemblies by means of single crystal X-ray diffraction experiments. One of the core limitations of the current methods is that crystal samples degrade as they are subject to X-rays, and two broad groups of effects are observed: global and specific damage. While the currently successful approach is to operate outside the range where global damage is observed, specific damage is not well understood and may lead to poor interpretation of the chemistry and biology of the system under study. In this work, we present a phenomenological model in which specific damage is understood as the result of a single process, the steady excitation of crystal electrons caused by X-ray absorption, which acts as a trigger for the bulk effects that manifest themselves in the form of global damage and obscure the interpretation of chemical information from XFEL and synchrotron structural research.


Author(s):  
José Brandão-Neto ◽  
Leonardo Bernasconi

Macromolecular crystallography at cryogenic temperatures has so far provided the majority of the experimental evidence that underpins the determination of the atomic structures of proteins and other biomolecular assemblies by means of single crystal X-ray diffraction experiments. One of the core limitations of the current methods is that crystal samples degrade as they are subject to X-rays, and two broad groups of effects are observed: global and specific damage. While the currently successful approach is to operate outside the range where global damage is observed, specific damage is not well understood and may lead to poor interpretation of the chemistry and biology of the system under study. In this work, we present a phenomenological model in which specific damage is understood as the result of a single process, the steady excitation of crystal electrons caused by X-ray absorption, which acts as a trigger for the bulk effects that manifest themselves in the form of global damage and obscure the interpretation of chemical information from XFEL and synchrotron structural research.


2017 ◽  
Vol 17 (2) ◽  
pp. 107-110
Author(s):  
K. Stec ◽  
J. Podwórny ◽  
B. Psiuk ◽  
Ł. Kozakiewicz

Abstract Using the available analytical methods, including the determination of chemical composition using wavelength-dispersive X-ray fluorescent spectroscopy technique and phase composition determined using X-ray diffraction, microstructural observations in a highresolution scanning microscope equipped with an X-ray microanalysis system as well as determination of characteristic softening and sintering temperatures using high-temperature microscope, the properties of particular chromite sands were defined. For the study has been typed reference sand with chemical properties, physical and thermal, treated as standard, and the sands of the regeneration process and the grinding process. Using these kinds of sand in foundries resulted in the occurrence of the phenomenon of the molding mass sintering. Impurities were identified and causes of sintering of a moulding sand based on chromite sand were characterized. Next, research methods enabling a quick evaluation of chromite sand suitability for use in the preparation of moulding sands were selected.


1983 ◽  
Vol 27 ◽  
pp. 159-170 ◽  
Author(s):  
K. Perry ◽  
I.C. Noyan ◽  
P.J. Rudnik ◽  
J.B. Cohen

Residual and applied stresses (σij) are often measured via X-ray diffraction, by calculating the resultant elastic strains (ϵij) from the measured change in interplanar spacing (“d”). This method is non-destructive, reasonably reproducible (typically ±14 MPa), can be carried out in the field, and is readily automated to give values to an operator-specified precision , Let Li represent the axes of the measuring system with L3 normal to the diffracting planes, and Pi represent the sample axes. These axes are illustrated in Figure 1. In what follows, primed stresses and strains are in the laboratory system, while unprimed values are in the sample system.


2010 ◽  
Vol 81 (14) ◽  
Author(s):  
Yoshikazu Tanaka ◽  
Taro Kojima ◽  
Yasutaka Takata ◽  
Ashish Chainani ◽  
Stephen W. Lovesey ◽  
...  

2016 ◽  
Vol 23 (3) ◽  
pp. 729-734 ◽  
Author(s):  
Roland Resel ◽  
Markus Bainschab ◽  
Alexander Pichler ◽  
Theo Dingemans ◽  
Clemens Simbrunner ◽  
...  

Dynamical scattering effects are observed in grazing-incidence X-ray diffraction experiments using an organic thin film of 2,2′:6′,2′′-ternaphthalene grown on oxidized silicon as substrate. Here, a splitting of all Bragg peaks in the out-of-plane direction (z-direction) has been observed, the magnitude of which depends both on the incidence angle of the primary beam and the out-of-plane angle of the scattered beam. The incident angle was varied between 0.09° and 0.25° for synchrotron radiation of 10.5 keV. This study reveals comparable intensities of the split peaks with a maximum for incidence angles close to the critical angle of total external reflection of the substrate. This observation is rationalized by two different scattering pathways resulting in diffraction peaks at different positions at the detector. In order to minimize the splitting, the data suggest either using incident angles well below the critical angle of total reflection or angles well above, which sufficiently attenuates the contributions from the second scattering path. This study highlights that the refraction of X-rays in (organic) thin films has to be corrected accordingly to allow for the determination of peak positions with sufficient accuracy. Based thereon, a reliable determination of the lattice constants becomes feasible, which is required for crystallographic structure solutions from thin films.


2006 ◽  
Vol 524-525 ◽  
pp. 743-748 ◽  
Author(s):  
Alexander M. Korsunsky ◽  
Shu Yan Zhang ◽  
Daniele Dini ◽  
Willem J.J. Vorster ◽  
Jian Liu

Diffraction of penetrating radiation such as neutrons or high energy X-rays provides a powerful non-destructive method for the evaluation of residual stresses in engineering components. In particular, strain scanning using synchrotron energy-dispersive X-ray diffraction has been shown to offer a fast and highly spatially resolving measurement technique. Synchrotron beamlines provide best available instruments in terms of flux and low beam divergence, and hence spatial and measurement resolution and data collection rate. However, despite the rapidly growing number of facilities becoming available in Europe and across the world, access to synchrotron beamlines for routine industrial and research use remains regulated, comparatively slow and expensive. A laboratory high energy X-ray diffractometer for bulk residual strain evaluation (HEXameter) has been developed and built at Oxford University. It uses a twin-detector setup first proposed by one of the authors in the energy dispersive X-ray diffraction mode and allows simultaneous determination of macroscopic and microscopic strains in two mutually orthogonal directions that lie approximately within the plane normal to the incident beam. A careful procedure for detector response calibration is used in order to facilitate accurate determination of lattice parameters by pattern refinement. The results of HEXameter measurements are compared with synchrotron X-ray data for several samples e.g. made from a titanium alloy and a particulate composite with an aluminium alloy matrix. Experimental results are found to be consistent with synchrotron measurements and strain resolution close to 2×10-4 is routinely achieved by the new instrument.


2018 ◽  
Vol 212 ◽  
pp. 161-166 ◽  
Author(s):  
Adam C. Lindsey ◽  
Matthew Loyd ◽  
Maulik K. Patel ◽  
Ryan Rawl ◽  
Haidong Zhou ◽  
...  

1999 ◽  
Vol 563 ◽  
Author(s):  
Delrose Winter ◽  
Paul R. Besser

AbstractX-Ray diffraction (XRD) provides an excellent tool for the measurement of both stress and texture (preferred orientation) on fabricated damascene interconnect structures. Since x-ray diffraction provides a direct measurement of lattice spacings, film strain can be measured directly. Also, since the intensity of diffracted x-rays is proportional to the density of lattice planes oriented in diffracting condition with respect to the incident beam, both the direction and extent of preferred orientation can be accurately measured. Special techniques and considerations are necessary when examining damascene interconnect structures with XRD which are not necessary with blanket films. These techniques are discussed and described in order to aid in obtaining meaningful XRD data and a correct interpretation of the results.