synchrotron beamlines
Recently Published Documents


TOTAL DOCUMENTS

61
(FIVE YEARS 9)

H-INDEX

14
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Anton Davydok ◽  
Yuriy N. Luponosov ◽  
Sergey A. Ponomarenko ◽  
Souren Grigorian

Abstract A compact voltage application setup has been developed for in-situ electrical testing of organic field effect transistors in combination with X-ray scattering studies at a synchrotron beamlines. Challenges faced during real condition in-operando test of newly developed OFETs originated an idea of creation of a new setup which excludes number of factors that make experiments complicated. The application of the setup is demonstrated on a prototype of an organic transistors based on α,ω-dihexyl-α-quaterthiophene molecules. The new setup allows to monitor material structural changes by X-ray scattering under applied voltage conditions and their direct correlations. The versatile setup eliminates possible shadowing effects and short circuits due to misalignment of the contacts. The electrical stability of the prototypes was characterized by the application of different voltage values. Corresponding structural changes were monitored by grazing X-ray scattering technique before, during and after the voltage was applied. The selected oligothiophene material with proved transistor properties shows high stability and directional anisotropy under applied voltage conditions. Thanks to a compact and flexible design of the setup different type of small dimension devices could be studied under external voltage conditions at various synchrotron beamlines.


2021 ◽  
Vol 28 (4) ◽  
Author(s):  
Lin Yang ◽  
Edwin Lazo ◽  
James Byrnes ◽  
Shirish Chodankar ◽  
Stephen Antonelli ◽  
...  

During the COVID-19 pandemic, synchrotron beamlines were forced to limit user access. Performing routine measurements became a challenge. At the Life Science X-ray Scattering (LiX) beamline, new instrumentation and mail-in protocols have been developed to remove the access barrier to solution scattering measurements. Our efforts took advantage of existing instrumentation and coincided with the larger effort at NSLS-II to support remote measurements. Given the limited staff–user interaction for mail-in measurements, additional software tools have been developed to ensure data quality, to automate the adjustments in data processing, as users would otherwise rely on the experience of the beamline staff, and produce a summary of the initial assessments of the data. This report describes the details of these developments.


2020 ◽  
Vol 27 (6) ◽  
pp. 1681-1687
Author(s):  
Ian Butler ◽  
Florian Fusseis ◽  
Alexis Cartwright-Taylor ◽  
Michael Flynn

An X-ray transparent experimental triaxial rock deformation apparatus, here named `Mjölnir', enables investigations of brittle-style rock deformation and failure, as well as coupled thermal, chemical and mechanical processes relevant to a range of Earth subsurface environments. Designed to operate with cylindrical samples up to 3.2 mm outside-diameter and up to 10 mm length, Mjölnir can attain up to 50 MPa confining pressure and in excess of 600 MPa axial load. The addition of heaters extends the experimental range to temperatures up to 140°C. Deployment of Mjolnir on synchrotron beamlines indicates that full 3D datasets may be acquired in a few seconds to a few minutes, meaning full 4D investigations of deformation processes can be undertaken. Mjölnir is constructed from readily available materials and components and complete technical drawings are included in the supporting information.


Agronomy ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 577 ◽  
Author(s):  
Surendra Bhattarai ◽  
Dilip Biswas ◽  
Yong-Bi Fu ◽  
Bill Biligetu

Alfalfa (Medicago sativa L.) is an important legume forage crop. However, its genetic improvement for salt tolerance is challenging, as alfalfa’s response to salt stress is genetically and physiologically complex. A review was made to update the knowledge of morphological, physiological, biochemical, and genetic responses of alfalfa plants to salt stress, and to discuss the potential of applying modern plant technologies to enhance alfalfa salt-resistant breeding, including genomic selection, RNA-Seq analysis, and cutting-edge Synchrotron beamlines. It is clear that alfalfa salt tolerance can be better characterized, genes conditioning salt tolerance be identified, and new marker-based tools be developed to accelerate alfalfa breeding for salt tolerance.


2019 ◽  
Vol 26 (6) ◽  
pp. 1924-1928 ◽  
Author(s):  
Caitlin Horn ◽  
Keara M. Ginell ◽  
Robert B. Von Dreele ◽  
Andrey A. Yakovenko ◽  
Brian H. Toby

Calibration of area detectors from powder diffraction standards is widely used at synchrotron beamlines. From a single diffraction image, it is not possible to determine both the sample-to-detector distance and the wavelength, but, with images taken from multiple positions along the beam direction and where the relative displacement is known, the sample-to-detector distance and wavelength can both be determined with good precision. An example calibration using the GSAS-II software package is presented.


2019 ◽  
Vol 90 (2) ◽  
pp. 021714 ◽  
Author(s):  
M. Thomasset ◽  
J. Dvorak ◽  
S. Brochet ◽  
D. Dennetiere ◽  
F. Polack
Keyword(s):  
X Ray ◽  

2019 ◽  
Vol 26 (1) ◽  
pp. 194-204 ◽  
Author(s):  
Emanuel Larsson ◽  
Doğa Gürsoy ◽  
Francesco De Carlo ◽  
Erica Lilleodden ◽  
Malte Storm ◽  
...  

Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during the acquisition of the series of tomographic projections. The ability to correct for vertical and horizontal distortions of each projection image during acquisition is necessary in order to achieve the effective 3D spatial resolution. The effectiveness of such an image alignment is also heavily influenced by the absorption properties and strong contrast of specific features in the scanned sample. Here it is shown that nanoporous gold (NPG) can be used as an ideal 3D test pattern for evaluating and optimizing the performance of a TXM instrument for hard X-rays at a synchrotron beamline. Unique features of NPG, such as hierarchical structures at multiple length scales and high absorbing capabilities, makes it an ideal choice for characterization, which involves a combination of a rapid-alignment algorithm applied on the acquired projections followed by the extraction of a set of both 2D- and 3D-descriptive image parameters. This protocol can be used for comparing the efficiency of TXM instruments at different synchrotron beamlines in the world or benchtop devices, based on a reference library of scanned NPG samples, containing information about the estimated horizontal and vertical alignment values, 2D qualitative parameters and quantitative 3D parameters. The possibility to tailor the ligament sizes of NPG to match the achievable resolution in combination with the high electron density of gold makes NPG an ideal 3D test pattern for evaluating the status and performance of a given synchrotron-based or benchtop-based TXM setup.


2018 ◽  
Vol 25 (4) ◽  
pp. 935-943 ◽  
Author(s):  
Christopher T. Chantler ◽  
Bruce A. Bunker ◽  
Hitoshi Abe ◽  
Masao Kimura ◽  
Matthew Newville ◽  
...  

Round robin studies have been used across fields of science for quality control testing and to investigate laboratory dependencies and cross-platform inconsistencies as well as to drive forward the improvement of understanding of experimental systems, systematic effects and theoretical limitations. Here, following the Q2XAFS Workshop and Satellite to IUCr Congress 2017 on `Data Acquisition, Treatment, Storage – quality assurance in XAFS spectroscopy', a mechanism is suggested for a suitable study across XAFS (X-ray absorption fine-structure) beamlines and facilities, to enable each beamline to cross-calibrate, provide representative test data, and to enable collaborative cross-facility activities to be more productive.


Sign in / Sign up

Export Citation Format

Share Document