scholarly journals Decay Heat Removal and Transient Analysis in Accidental Conditions in the EFIT Reactor

2008 ◽  
Vol 2008 ◽  
pp. 1-8 ◽  
Author(s):  
Giacomino Bandini ◽  
Paride Meloni ◽  
Massimiliano Polidori ◽  
Maddalena Casamirra ◽  
Francesco Castiglia ◽  
...  

The development of a conceptual design of an industrial-scale transmutation facility (EFIT) of several 100 MW thermal power based on accelerator-driven system (ADS) is addressed in the frame of the European EUROTRANS Integral Project. In normal operation, the core power of EFIT reactor is removed through steam generators by four secondary loops fed by water. A safety-related decay heat removal (DHR) system provided with four independent inherently safe loops is installed in the primary vessel to remove the decay heat by natural convection circulation under accidental conditions which are caused by a loss-of-heat sink (LOHS). In order to confirm the adequacy of the adopted solution for decay heat removal in accidental conditions, some multi-D analyses have been carried out with the SIMMER-III code. The results of the SIMMER-III code have been then used to support the RELAP5 1D representation of the natural circulation flow paths in the reactor vessel. Finally, the thermal-hydraulic RELAP5 code has been employed for the analysis of LOHS accidental scenarios.

2019 ◽  
Vol 125 ◽  
pp. 242-248
Author(s):  
Takanori Sugawara ◽  
Hayanori Takei ◽  
Kazufumi Tsujimoto

2014 ◽  
Vol 137 (3) ◽  
Author(s):  
Lorenzo Damiani ◽  
Alessandro Pini Prato

The generation IV lead cooled fast reactors are of particular interest for the Italian research: several influential companies (Ansaldo Nucleare, ENEA) are involved in these important European R&D projects. At present, one significant European project in progress is lead cooled European advanced demonstrator reactor (LEADER) which includes, among its goals, the construction of a lead-cooled fast reactor demonstrator, advanced lead fast reactor European demonstrator (ALFRED). The demonstrator has to include technical solutions that simplify the construction phase and assure full safety in operation; according to the latest guidelines, ALFRED final configuration will be characterized by a secondary loop providing bayonet-tube steam generators. The authors have addressed the issue of bayonet-tube steam generators proposing the external boiling bayonet steam generator (EBBSG) system, in which the reaction heat is extracted from the lead by means of coolant under vapor phase. This is possible thanks to an external feed-water boiling, based on the known Loeffler scheme, coupled to the bayonet tube concept. In the present paper, the authors propose a decay heat removal (DHR) system to match the EBBSG scheme. The DHR system is fully passive, exploiting natural circulation phenomena. The performance of the proposed DHR system is investigated through a Matlab-Simulink model. The results are satisfactory since, according to the simulations, the proposed DHR system is able to keep the primary coolant temperature within a safety range for a sufficient time, avoiding the lead freezing or over-heating.


Author(s):  
Rui Hu ◽  
Darius D. Lisowski ◽  
Matthew Bucknor ◽  
Adam R. Kraus ◽  
Qiuping Lv

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). One such variant, air-cooled RCCS, uses natural convection to drive the flow of air from outside the reactor building to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a half-scale model of the primary features of one conceptual air-cooled RCCS design. The facility was constructed to carry out highly instrumented experiments to study the performance of the RCCS concept for reactor decay heat removal that relies on natural convection cooling. Parallel modeling and simulation efforts were performed to support the design, operation, and analysis of the natural convection system. Throughout the testing program, strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under the same test procedures. Thus, significant analysis efforts were devoted to gaining a better understanding of these influences and the subsequent response of the NSTF to ambient conditions. It was determined that air humidity had negligible impacts on NSTF system performance and therefore did not warrant consideration in the models. However, temperature differences between the building exterior and interior air, along with the outside wind speed, were shown to be dominant factors. Combining the stack and wind effects together, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions. Some coefficients in the model were obtained based on best fitting the experimental data. The predictive capability of the empirical model was demonstrated by applying it to the new set of experimental data. The empirical model was also implemented in the computational models of the NSTF using both RELAP5-3D and STAR-CCM+ codes. Accounting for the effects of ambient conditions, simulations from both codes predicted the natural circulation flow rates very well.


Author(s):  
Jeremy Bittan ◽  
Clement Bore ◽  
Joel Guidez

Abstract In the frame of the ESFR-SMART European project, aiming at improving the safety level of the European Sodium cooled Fast Reactor (ESFR), this paper presents the preliminary assessment of decay heat removal systems in the ESFR-SMART design: the role of natural air convection around Steam Generators outer shells in accidental conditions. Both theoretical and CATHARE code (Thermal Hydraulics reference code) calculations are presented. The impact of an additional chimney at the top of each casing as well as running primary and secondary pumps on the heat removal capacity are equally evaluated. This paper shows that the evacuation of decay heat thanks to completely passive air natural circulation alone, in case of Fukushima like accident, should lead to temperatures of sodium in the reactor vessel temporarily exceeding the safety criterion of 650°C. The addition of chimneys increase the capacities but is not sufficient to evacuate the decay heat safely. If the primary and secondary side pumps are running, the safety criterion should be met.


2020 ◽  
Vol 6 (4) ◽  
Author(s):  
G. Mayer ◽  
A. Guba

Abstract ALLEGRO is a helium-cooled fast reactor, which is being developed by the Czech Republic, France, Hungary, Slovakia, and Poland. It will be the demonstrator of the GFR-2400-MWth Generation IV gas-cooled fast reactors. In ALLEGRO, a three-loop safety system is designed to remove decay heat during accident conditions. The nonrotating blower blades may represent a huge pressure loss in the decay heat removal loop (DHR), which hinders natural circulation. The lower the pressure loss coefficient of the DHR blower blades is, the better cooling is available during natural circulation. On the other hand, a large core bypass develops if a DHR valve is opened inadvertently during normal operation. In this case, the higher DHR blower pressure loss is better from core cooling point of view. Consequently, the low pressure loss of the DHR blower is advantageous for core cooling in station blackout (SBO) event but disadvantageous for inadvertent DHR valve opening event. Both the above-mentioned cases may lead to insufficient core cooling in accident conditions, which threatens the integrity of the reactor core. In this study, we present CATHARE thermohydraulic calculations to assess the sensitivity of the DHR blower pressure loss coefficient for the above-mentioned two cases.


2008 ◽  
Vol 2008 ◽  
pp. 1-11 ◽  
Author(s):  
Avinash J. Gaikwad ◽  
P. K. Vijayan ◽  
Sharad Bhartya ◽  
Kannan Iyer ◽  
Rajesh Kumar ◽  
...  

Provision of passive means to reactor core decay heat removal enhances the nuclear power plant (NPP) safety and availability. In the earlier Indian pressurised heavy water reactors (IPHWRs), like the 220 MWe and the 540 MWe, crash cooldown from the steam generators (SGs) is resorted to mitigate consequences of station blackout (SBO). In the 700 MWe PHWR currently being designed an additional passive decay heat removal (PDHR) system is also incorporated to condense the steam generated in the boilers during a SBO. The sustainability of natural circulation in the various heat transport systems (i.e., primary heat transport (PHT), SGs, and PDHRs) under station blackout depends on the corresponding system's coolant inventories and the coolant circuit configurations (i.e., parallel paths and interconnections). On the primary side, the interconnection between the two primary loops plays an important role to sustain the natural circulation heat removal. On the secondary side, the steam lines interconnections and the initial inventory in the SGs prior to cooldown, that is, hooking up of the PDHRs are very important. This paper attempts to open up discussions on the concept and the core issues associated with passive systems which can provide continued heat sink during such accident scenarios. The discussions would include the criteria for design, and performance of such concepts already implemented and proposes schemes to be implemented in the proposed 700 MWe IPHWR. The designer feedbacks generated, and critical examination of performance analysis results for the added passive system to the existing generation II & III reactors will help ascertaining that these safety systems/inventories in fact perform in sustaining decay heat removal and augmenting safety.


Author(s):  
Byoung-Uhn Bae ◽  
Seok Kim ◽  
Yu-Sun Park ◽  
Bok-Deuk Kim ◽  
Kyoung-Ho Kang ◽  
...  

The Passive Auxiliary Feedwater System (PAFS) is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor Plus) which is intended to completely replace the conventional active auxiliary feedwater system. It removes the decay heat by cooling down the secondary system of the SG using condensation heat exchanger installed in the Passive Condensation Cooling Tank (PCCT). With an aim of validating the cooling and operational performance of the PAFS, PASCAL (PAFS Condensing Heat Removal Assessment Loop), was constructed to experimentally investigate the condensation heat transfer and natural convection phenomena in the PAFS. It simulates a single tube of the passive condensation heat exchangers, a steam-supply line, a return-water line, and a PCCT with a reduced area, which is equivalent to 1/240 of the prototype according to a volumetric scaling methodology with a full height. The objective of the experiment is to investigate the cooling performance and natural circulation characteristics of the PAFS by simulating a steady state condition of the thermal power. From the experiment, two-phase flow phenomena in the horizontal heat exchanger and PCCT were investigated and the cooling capability of the condensation heat exchanger was validated. Test results showed that the design of the condensation heat exchanger in PAFS could satisfy the requirement for heat removal rate of 540 kW per a single tube and the prevention of water hammer phenomenon inside the tube. It also proved that the operation of PAFS played an important role in cooling down the decay heat by natural convection without any active system. The present experimental results will contribute to improve the model of the condensation and boiling heat transfer, and also to provide the benchmark data for validating the calculation performance of a thermal hydraulic system analysis code with respect to the PAFS.


Sign in / Sign up

Export Citation Format

Share Document