scholarly journals Determination of Mesalamine Related Impurities from Drug Product by Reversed Phase Validated UPLC Method

2011 ◽  
Vol 8 (1) ◽  
pp. 131-148 ◽  
Author(s):  
Trivedi Rakshit Kanubhai ◽  
Patel Mukesh C ◽  
Kharkar Amit R

In the present study gradient reversed-phase UPLC method was developed for simultaneous determination and separation of impurities and degradation products from drug product. The chromatographic separation was performed on acquity UPLC BEH C18 column (50 mm×2.1 mm, 1.7 µm) using gradient elution. Other UPLC parameters which were optimised are flow rate, 0.7 mL/min; detection wavelength, 220 nm; column oven temperature, 40°C and injection volume 7 µL. Stability indicating capability was established by forced degradation experiments and separation of known degradation products. The method was validated as per International Conference on Harmonization (ICH) guideline. For all impurities and mesalamine, LOQ (limit of quantification) value was found precise with RSD (related standard daviation) of less than 2.0%. In essence, the present study provides an improved low detection limit and lower run time for evaluation of pharmaceutical quality of mesalamine delayed-release formulation. Moreover, the developed method was successfully applied for quantification of impurities and degradation products in mesalamine delayed-release formulation. The same method can also be used for determination of related substances from mesalamine drug substance.

2011 ◽  
Vol 8 (1) ◽  
pp. 167-179 ◽  
Author(s):  
Rakshit Kanubhai Trivedi ◽  
Mukesh C. Patel

A reversed phase ultra performance liquid chromatography (UPLC) method was developed and validated for the quantification of aniline in mesalamine delayed-release tablets. The optimization of the experimental condition was carried out considering some important requirements like, detection limit, short run time and reproducibility. In the present study, isocratic reversed-phase UPLC method was developed for determination and separation of aniline from the drug product. The drug and impurity are well separated by using a reversed phase (Reprosil Gold C18-XBD) column and mobile phase comprising of buffer pH 6.0 and acetonitrile in the ratio of 90:10 v/v. Other UPLC parameters which were optimised are flow rate, 0.5 mL/min; detection wavelength, 200 nm; column oven temperature, 50°C and injection volume 7 µL. Stability indicating capability was also established by forced degradation experiments. The method was validated as per ICH guideline. LOQ (limit of quantification) concentration (18 ng/mL) was found precise with RSD of less than 2%. In essence, the present study provides an improved low detection limit and lower run time for evaluation of pharmaceutical quality of mesalamine delayed-release formulation. Moreover, the developed method was also successfully applied for quantification of aniline in mesalamine delayed-release formulation. The same method can also be used for determination of aniline from drug substances.


2011 ◽  
Vol 30 (2) ◽  
pp. 139 ◽  
Author(s):  
Ana Petkovska ◽  
Hristina Babunovska ◽  
Marina Stefova

Quality control of pharmaceuticals requires development of fast, efficient and reliable methods for determination of active compounds as well as known and very often unknown impurities within defined concentration ranges. In this work, a simple and rapid HPLC-UV-DAD method for identification and quantification of pholcodine process related impurities and some degradation products was developed and validated. Pholcodine and its five structural analogues such as morphine, codeine, thebaine, oripavine, and papaverine were separated in less than 10 minutes using reversed phase LiChrospher C-8 column. For optimal chromatographic performance with reproducible retention times, gradient elution with 2% ammonium hydroxide in water and acetonitrile was used. The method was validated by establishing its selectivity, specifity, sensitivity, linearity, intra- and inter-day precision and robustness. All tested parameters confirmed that the method is suitable for determination of pholcodine and its five impurities in pharmaceutical drug samples. The results obtained from real sample analysis give support to the suitability of the proposed method for the purpose of quality control.


2011 ◽  
Vol 94 (1) ◽  
pp. 143-149 ◽  
Author(s):  
Hitesh B Patel ◽  
Arivozhi Mohan ◽  
Hitendra S Joshi

Abstract A simple RP-ultra-performance LC method was developed and validated for determination of impurities related to torsemide tablets. The rapid method provided adequate separation of all known related impurities and degradation products. Separation was achieved on a Zorbax SB-C18 column (50 × 4.6 mm id, 1.8 μm particle size) with binary gradient elution, and detection was performed at 288 nm. The drug product was subjected to oxidative, hydrolytic, photolytic, and thermal stress conditions to prove the specificity of the proposed method. The linearity and recovery were investigated for known impurities in the range of 0.025 to 1.0%, with respect to the drug concentration in the prepared sample. The linearity of the calibration curve for each of the impurities and torsemide was found to be very good (r2 > 0.999). Relative response factors for each of the known impurities were established by the slope ratio method from the linearity study.


2011 ◽  
Vol 94 (6) ◽  
pp. 1800-1806 ◽  
Author(s):  
Arivozhi Mohan ◽  
Hitesh B Patel ◽  
Dhandayutham Saravanan

Abstract A simple isocratic, RP-ultra-performance LC method was developed and validated for the determination of lacidipine, three process impurities formed during synthesis, and three degradation products present in drug substance and the drug product. An efficient chromatographic separation was achieved on an Acquity BEH C18 column using pH 4.5 ammonium acetate–acetic acid buffer–methanol (70 + 30, v/v) mobile phase. The monitoring wavelength was 240 nm, and the flow rate 0.25 mL/min. Forced degradation studies using acid, alkali, peroxide, water, heat, and light were conducted, and all impurities were separated. The method was validated successfully for specificity, precision, linearity, accuracy, LOD, LOQ, and robustness, according to International Conference on Harmonization guidelines. The linearity of the calibration curve for lacidipine and each impurity was found to be very good (r2 > 0.999). This method is shown to be suitable for analysis of lacidipine to evaluate the quality of drug substance and a drug product.


2019 ◽  
Vol 15 (7) ◽  
pp. 694-702
Author(s):  
Sonia Talaat Hassib ◽  
Hanaa Abdelmenem Hashem ◽  
Marwa Ahmed Fouad ◽  
Nehal Essam Eldin Mohamed

Introduction: (COPD) Chronic Obstructive Pulmonary Disease is a partially reversible and treatable lung disease, characterized by progressive limitation of airflow. It is one of the main causes of mortality and morbidity worldwide. Methods: An easy, precise and selective reversed-phase liquid chromatographic method, with stabilityindicating assay was established and validated for the determination of indacaterol maleate and glycopyrronium bromide in the mixture. In addition, a forced degradation study was performed for indacaterol maleate, comprised of hydrolysis by acid and base, degradation by oxidation and heat, and photo-degradation. Separation and forced degradation were done by isocratic elution using a reversed phase phenyl column and (methanol: phosphate buffer) at ratio (65:35, v/v) with 3.5 pH buffer as an eluent at 1 mL min-1 as a flow rate. Quantitation was accomplished using a UV detector at 210 nm. Results: The method showed good separation of glycopyrronium bromide, indacaterol maleate and its degradation products. Accuracy, linearity, and precision were acceptable over 10-160 µg mL-1 and 10- 80 µg mL-1 concentration range for indacaterol maleate and glycopyrronium bromide, respectively. Conclusion: The proposed method does not require any previously done separation steps, making it applicable for the analysis of the drugs under investigation in their pharmaceutically marketed preparations.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (05) ◽  
pp. 56-64
Author(s):  
Rani A Prameela ◽  
S. Madhavi ◽  
Rao B. Tirumaleswara ◽  
Sudheer Reddy CH.

A novel Ultra Performance Liquid Chromatography (UPLC) method was developed and validated for the simultaneous determination of antidiabetic drugs metformin hydrochloride and nateglinide. The method was developed using a Waters ACQUITY UPLC SB C18 (100 × 2.1 mm, 1.8 μm) column. The mobile phase consisting of 0.01 % potassium dihydrogen phosphate buffer (pH 5.8): acetonitrile (50: 50 V/V) was used throughout the analysis. The flow rate was 0.3 mL/min, the injection volume was 1.0 μL, column temperature was 30 0C, run time 3 min and detection was carried at 238 nm using a TUV detector. The retention times of metformin hydrochloride and nateglinide were found to be 1.28 1.71 min, respectively. Metformin hydrochloride and nateglinide were found to be linear over the concentration range of 125-750 and 15-90 μg/mL. The limit of detection and the limit of quantification for metformin hydrochloride were found to be 0.22 and 0.68 μg/mL, respectively, and, for nateglinide, 0.02 and 0.6 μg/mL, respectively. Developed method was validated as per ICH guidelines. The specificity of the method was confirmed by forced degradation study. The suggested method is suitable for determination of metformin hydrochloride and nateglinide in bulk and pharmaceutical dosage forms.


2014 ◽  
Vol 6 (12) ◽  
pp. 4437-4445 ◽  
Author(s):  
Karen de Souza Rugani ◽  
Hérida Regina Nunes Salgado

A stability-indicating gradient reversed phase liquid chromatography (RP-LC) method has been developed for the quantitative determination of cephalothin (CET), an antimicrobial compound, in the presence of its impurities and degradation products generated from forced degradation studies.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
Kanakapura B. Vinay ◽  
Hosakere D. Revanasiddappa ◽  
Cijo M. Xavier ◽  
Pavagada J. Ramesh ◽  
Madihalli S. Raghu

The use of Ultra Performance Liquid Chromatography (UPLC), with a rapid 5-minute reversed phase isocratic separation on a 1.7 μm reversed-phase packing material to provide rapid ‘‘high throughput’’ support for tramadol hydrochloride (TMH) is demonstrated. A simple, precise and accurate stability-indicating isocratic UPLC method was developed for the determination of TMH in bulk drug and in its tablets. The method was developed using Waters Aquity BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with mobile phase consisting of a mixture of potassium dihydrogen phosphate buffer of pH 2.8 and an equal volume of acetonitrile (60 : 40 v/v). The eluted compound was detected at 226 nm with a UV detector. The standard curve of mean peak area versus concentration showed an excellent linearity over a concentration range 0.5–300 μg mL−1 TMH with regression coefficient (r) value of 0.9999. The limit of detection (S/N =3) was 0.08 μg mL−1 and the limit of quantification (S/N =10) was 0.2 μg mL−1. Forced degradation of the bulk sample was conducted an accordance with the ICH guidelines. Acidic, basic, hydrolytic, oxidative, thermal and photolytic degradation were used to assess the stability indicating power of the method. TMH was found to degrade significantly in acidic, basic and oxidative stress conditions and stable in thermal, hydrolytic and photolytic conditions.


2020 ◽  
Vol 32 (2) ◽  
pp. 80-85
Author(s):  
Tingting Zhang ◽  
Wanting Yin ◽  
Bo Jin ◽  
Tong Li ◽  
Chen Ma

A sensitive, stability-indicating reversed-phase high-performance liquid chromatography with diode array detection (HPLC–DAD) method has been developed for the determination of TBI-166 and its 10 kinds of related impurities. Chromatographic separation was achieved on a Kromasil ODS column (250 mm × 4.6 mm, 5 μm), with a gradient elution of the mobile phase system consisting of acetonitrile and 1% ammonium formate solution (with 0.2% formic acid). The flow rate was 1.0 mL/min, and the detection wavelength was set at 251 nm. The method was validated according to the International Conference on Harmonization (ICH) guidelines with respect to selectivity, linearity, limits, accuracy, precision, and robustness. The calibration curves were linear from LOQ to 150% of the specification limit of impurity with correlation coefficients not less than 0.999. The limits of quantitation were between 0.123 and 0.257 μg/mL. Accuracy for the related substances was estimated by the recovery ranged from 94.6% to 111.2%. The method was proved to be reliable for the determination of related substances in TBI-166 bulk drug, which is essential and important in the quality control.


Sign in / Sign up

Export Citation Format

Share Document