scholarly journals Pressure Losses across Multiple Fittings in Ventilation Ducts

2013 ◽  
Vol 2013 ◽  
pp. 1-11 ◽  
Author(s):  
Z. T. Ai ◽  
C. M. Mak
2019 ◽  
Vol 302 ◽  
pp. 01021
Author(s):  
Kazimierz Peszynski ◽  
Václav Tesař ◽  
Ewa Kuliś

The paper presents a new ventilation system characterized by the cross-section of the channels in the shape of a rounded rectangle. The basic research problem was the determination of local losses in the system components. To achieve this goal, it is necessary to know the linear losses in the ducts. The principle of determining both types of losses was presented. The friction coefficients of linear pressure losses referred to the unit of the straight length of the duct section ζl[m−1] as well as generalized dimensionless friction coefficient of linear pressure losses λ [-] is presented. The main achievement of the paper is the statement that the lambda coefficient λ can replace the coefficients ζl examined duct cross-sections.


Equipment ◽  
2006 ◽  
Author(s):  
J. Sestak ◽  
V. Mik ◽  
J. Myska ◽  
M. Dostal ◽  
L. Mihalka

2003 ◽  
Vol 3 ◽  
pp. 208-219
Author(s):  
A.M. Ilyasov

In this paper we propose a model for determining the pressure loss due to friction in each phase in a three-layer laminar steady flow of immiscible liquid and gas flow in a flat channel. This model generalizes an analogous problem for a two-layer laminar flow, proposed earlier. The relations obtained in the final form for the pressure loss due to friction in liquids can be used as closing relations for the three-fluid model. These equations take into account the influence of interphase boundaries and are an alternative to the approach used in foreign literature. In this approach, the wall and interphase voltages are approximated by the formulas for a single-phase flow and do not take into account the mutual influence of liquids on the loss of pressure on friction in phases. The distribution of flow parameters in these two models is compared.


1988 ◽  
Vol 53 (4) ◽  
pp. 788-806
Author(s):  
Miloslav Hošťálek ◽  
Jiří Výborný ◽  
František Madron

Steady state hydraulic calculation has been described of an extensive pipeline network based on a new graph algorithm for setting up and decomposition of balance equations of the model. The parameters of the model are characteristics of individual sections of the network (pumps, pipes, and heat exchangers with armatures). In case of sections with controlled flow rate (variable characteristic), or sections with measured flow rate, the flow rates are direct inputs. The interactions of the network with the surroundings are accounted for by appropriate sources and sinks of individual nodes. The result of the calculation is the knowledge of all flow rates and pressure losses in the network. Automatic generation of the model equations utilizes an efficient (vector) fixing of the network topology and predominantly logical, not numerical operations based on the graph theory. The calculation proper utilizes a modification of the model by the method of linearization of characteristics, while the properties of the modified set of equations permit further decrease of the requirements on the computer. The described approach is suitable for the solution of practical problems even on lower category personal computers. The calculations are illustrated on an example of a simple network with uncontrolled and controlled flow rates of cooling water while one of the sections of the network is also a gravitational return flow of the cooling water.


Fluids ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 25
Author(s):  
Iris Gerken ◽  
Thomas Wetzel ◽  
Jürgen J. Brandner

Micro heat exchangers have been revealed to be efficient devices for improved heat transfer due to short heat transfer distances and increased surface-to-volume ratios. Further augmentation of the heat transfer behaviour within microstructured devices can be achieved with heat transfer enhancement techniques, and more precisely for this study, with passive enhancement techniques. Pin fin geometries influence the flow path and, therefore, were chosen as the option for further improvement of the heat transfer performance. The augmentation of heat transfer with micro heat exchangers was performed with the consideration of an improved heat transfer behaviour, and with additional pressure losses due to the change of flow path (pin fin geometries). To capture the impact of the heat transfer, as well as the impact of additional pressure losses, an assessment method should be considered. The overall exergy loss method can be applied to micro heat exchangers, and serves as a simple assessment for characterization. Experimental investigations with micro heat exchanger structures were performed to evaluate the assessment method and its importance. The heat transfer enhancement was experimentally investigated with microstructured pin fin geometries to understand the impact on pressure loss behaviour with air.


Author(s):  
Karsten Tawackolian ◽  
Martin Kriegel

AbstractThis study looks to find a suitable turbulence model for calculating pressure losses of ventilation components. In building ventilation, the most relevant Reynolds number range is between 3×104 and 6×105, depending on the duct dimensions and airflow rates. Pressure loss coefficients can increase considerably for some components at Reynolds numbers below 2×105. An initial survey of popular turbulence models was conducted for a selected test case of a bend with such a strong Reynolds number dependence. Most of the turbulence models failed in reproducing this dependence and predicted curve progressions that were too flat and only applicable for higher Reynolds numbers. Viscous effects near walls played an important role in the present simulations. In turbulence modelling, near-wall damping functions are used to account for this influence. A model that implements near-wall modelling is the lag elliptic blending k-ε model. This model gave reasonable predictions for pressure loss coefficients at lower Reynolds numbers. Another example is the low Reynolds number k-ε turbulence model of Wilcox (LRN). The modification uses damping functions and was initially developed for simulating profiles such as aircraft wings. It has not been widely used for internal flows such as air duct flows. Based on selected reference cases, the three closure coefficients of the LRN model were adapted in this work to simulate ventilation components. Improved predictions were obtained with new coefficients (LRNM model). This underlined that low Reynolds number effects are relevant in ventilation ductworks and give first insights for suitable turbulence models for this application. Both the lag elliptic blending model and the modified LRNM model predicted the pressure losses relatively well for the test case where the other tested models failed.


Sign in / Sign up

Export Citation Format

Share Document