scholarly journals Noninvasive Electromagnetic Detection of Bladder Cancer

ISRN Urology ◽  
2014 ◽  
Vol 2014 ◽  
pp. 1-4 ◽  
Author(s):  
Luigi Cormio ◽  
Clarbruno Vedruccio ◽  
Giorgio Leucci ◽  
Paolo Massenio ◽  
Giuseppe Di Fino ◽  
...  

Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC.

Author(s):  
Shaoxu Wu ◽  
Xiong Chen ◽  
Jiexin Pan ◽  
Wen Dong ◽  
Xiayao Diao ◽  
...  

Abstract Background Cystoscopy plays an important role in bladder cancer (BCa) diagnosis and treatment, but its sensitivity needs improvement. Artificial intelligence has shown promise in endoscopy, but few cystoscopic applications have been reported. We report a Cystoscopy Artificial Intelligence Diagnostic System (CAIDS) for BCa diagnosis. Methods In total, 69,204 images from 10,729 consecutive patients from six hospitals were collected and divided into training, internal validation, and external validation sets. The CAIDS was built using a pyramid scene parsing network and transfer learning. A subset (n = 260) of the validation sets was used for a performance comparison between the CAIDS and urologists for complex lesion detection. The diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values and 95% confidence intervals (CIs) were calculated using the Clopper-Pearson method. Results The diagnostic accuracies of the CAIDS were 0.977 (95% CI = 0.974–0.979) in the internal validation set and 0.990 (95% CI = 0.979–0.996), 0.982 (95% CI = 0.974–0.988), 0.978 (95% CI = 0.959–0.989), and 0.991 (95% CI = 0.987–0.994) in different external validation sets. In the CAIDS versus urologists’ comparisons, the CAIDS showed high accuracy and sensitivity (accuracy = 0.939, 95% CI = 0.902–0.964; and sensitivity = 0.954, 95% CI = 0.902–0.983) with a short latency of 12 s, much more accurate and quicker than the expert urologists. Conclusions The CAIDS achieved accurate BCa detection with a short latency. The CAIDS may provide many clinical benefits, from increasing the diagnostic accuracy for BCa, even for commonly misdiagnosed cases such as flat cancerous tissue (carcinoma in situ), to reducing the operation time for cystoscopy.


2021 ◽  
pp. 25-28
Author(s):  
M. Vijaya Kumar ◽  
Manasa Manasa

Acute appendicitis is the most common condition encountered in the Emergency department .Alvarado and Modied Alvarado scores are the most commonly used scoring system used for diagnosing acute appendicitis.,but its performance has been found to be poor in certain population . Hence our aim was to compare the diagnostic accuracy of RIPASA and ALVARADO Scoring system and study and compare sensitivity, specicity and predictive values of these scoring systems. The study was conducted in Government district hospital Nandyal . We enrolled 176 patients who presented with RIF pain . Both RIPASA and ALVARADO were applied to them. Final diagnosis was conrmed either by CT scan, intra operative nding or post operative HPE report. Sensitivity,specicity, positive predictive value, negative predictive value, diagnostic accuracy was calculated both for RIPASA and ALVARADO. It was found that sensitivity and specicity of the RIPASA score in our study are 98.7% and 83.3%, respectively. PPV and NPV were 98.1% and 88.2% and sensitivity and specicity of the Alvardo score in our study are 94.3% and 83.3%, respectively. PPV and NPV were 98% and 62.5%.Diagnostic accuracy of RIPASA score and Alvarado score are 97% and 93% respectively. RIPASA is a more specic and accurate scoring system in our local population when compared to ALVARADO . It reduces the number of missed appendicitis cases and also convincingly lters out the group of patients that would need a CT scan for diagnosis (score 5-7.5 ) BACKGROUND: Acute appendicitis is one of the most commonly dealt surgical emergencies, with a lifetime prevalence rate of approximately 1 one in seven. The incidence is 1.5–1.9 per 1,000 in the male and female population, and is approximately 1.4 times greater in men than in women. Despite being a common problem, it remains a difcult diagnosis to establish, particularly among the young, the elderly and females of reproductive age, where a host of other genitourinary and gynaecological inammatory conditions can present with signs and symptoms that are 2 similar to those of acute appendicitis. A delay in performing an appendectomy in order to improve its diagnostic accuracy increases the risk of appendicular perforation and peritonitis, which in turn increases morbidity and mortality. A variable combination of clinical signs and symptoms has been used together with laboratory ndings in several scoring systems proposed for suggesting the probability of Acute Appendicitis and the possible subsequent management pathway. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) and ALVARADO score are new diagnostic scoring systems developed for the diagnosis of Acute Appendicitis and has been shown to have signicantly higher sensitivity, specicity and diagnostic accuracy. AIMS AND OBJECTIVES PRIMARY OBJECT 1. To compare RIPASA Scoring system and ALVARADO Scoring system in terms of diagnostic accuracy in Acute Appendicitis. 2. To study and compare sensitivity, specicity and predictive values of above scoring systems. SECONDARY OBJECT 1. To study the rate of negative appendicectomy based on above scoring systems. CONCLUSION: The RIPASA score is a simple scoring system with high sensitivity and specicity for the diagnosis of acute appendicitis. The 14 clinical parameters are all present in a good clinical history and examination and can be easily and quickly applied. Therefore, a decision on the management can be made early. Although the RIPASA score was developed for the local population of Brunei, we believe that it should be applicable to other regions. The RIPASA score presents greater Diagnostic accuracy and Sensitivity and equal specicity as a diagnostic test compared to the Alvarado score and is helpful in making appropriate therapeutic decisions. In hospitals like ours, the diagnosis of AA relies greatly on the clinical evaluation performed by surgeons. An adequate clinical scoring system would avoid diagnostic errors, maintaining a satisfactory low rate of negative appendectomies by adequate patient stratication, while limiting patient exposure to ionizing radiation, since 21 there is an increased risk of developing cancer with computed tomography, particularly for the paediatric age group.


2020 ◽  
Author(s):  
Tenzin Tenzin ◽  
Kelzang Lhamo ◽  
Purna B Rai ◽  
Dawa Tshering ◽  
Pema Jamtsho ◽  
...  

Abstract Background: Rabies kills approximately 59,000 people in the world each year worldwide. Rapid and accurate diagnosis of rabies is important for instituting rapid containment measures and for advising the exposed people for postexposure treatment. The application of a rapid diagnostic tests in the field can greatly enhance disease surveillance and diagnostic activities, especially in resource poor settings. In this study, a total of 179 brain tissue samples collected from different rabies suspect animal species (113 dogs, 50 cattle, 10 cats, 3 goats, 2 horses, and 1 bear) were selected and tested using both rapid immunochromatographic kit and the reference standard fluorescent antibody test (FAT). We evaluated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of a rapid antigen detection test kit produced by BioNote, Inc. (Hwaseong-si, Korea) relative to a FAT for its fit-for-purpose for confirmation of clinical cases of rabies for early response and enhancing rabies surveillance. Results: Among 179 samples examined in this study, there was a concordance in results by the rapid test and FAT in 115 positive samples and 54 negative samples. Test results were discordant in 10 samples which were positive by FAT, but negative (false negative) by rapid kit. The rapid test kit showed a sensitivity of 92% (95% CI: 85.9 – 95.6) and specificity of 100% (95% CI: 93.4 – 100) using FAT as the reference standard. The positive and negative predictive values were found to be 100% (95% CI:96.7 – 100) and 84.4% (95% CI: 73.6 – 91.3), respectively. Overall, there was 94.4% (95% CI: 90 – 96.9) test agreement between rapid test and FAT (Kappa value = 0.874) with a positive percent agreement and negative percent agreement of 92 and 100%, respectively. Conclusions: Our finding demonstrated that the rapid test kit (BioNote) can be used for rabies surveillance and confirming clinical case of rabies in animals for making rapid decisions particularly controlling rabies outbreaks in resource poor settings.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Xiaohong Pu ◽  
Hongwei Zheng ◽  
Xin Yang ◽  
Qing Ye ◽  
Zhiwen Fan ◽  
...  

Abstract Background Using fluorescence in situ hybridisation (FISH) to detect any gain of chromosomes 3, 7, or 17 and loss of the 9p21 locus has been proven to be sensitive in the diagnosis of pancreatobiliary tumors. However, both genetic and environmental factors contribute to the pathogenesis of pancreatobiliary tumors. Therefore, it is unknown whether this method is suitable for Chinese patients with pancreatobiliary tumors. This study aims to compare the sensitivity, specificity, predictive values and accuracy of cytology, ERCP/MRCP and FISH based on Chinese patients with pancreatobiliary tumors,and to analyze differences between brushing-based and formalin-fixed paraffin-embedded (FFPE)-based FISH. Methods A total of 66 brush cytology specimens obtained during ERCP were detected by FISH and cytology test respectively to compare the sensitivity, specificity, predictive values and accuracy. Besides, FFPE-based FISH was performed on 46 corresponding paraffin sections of pancreatobiliary tumors obtained by surgical resection. Results Our findings demonstrate that FISH greatly improves diagnostic sensitivity and negative predictive value compared to ERCP/MRCP and cytology without much reduction in specificity and positive predictive value. However, our results also indicate that FFPE-based FISH could not effectively identify the false-negative of brushing-based FISH. Conclusions We believe that FISH can effectively distinguish true positive and false positive results of cytological or radiological suspicions of malignancy. However, FFPE-based FISH still does not precisely recognize the false-negative of brushing-based FISH. Both cytology-based and PPFE-based FISH had limitation in some specimens.


2017 ◽  
Vol 21 (1) ◽  
Author(s):  
Monica S. Msomi ◽  
Hansraj Mangray ◽  
Vicci Du Plessis

Objectives: To compare radiological findings with the histological diagnosis of Hirschsprung disease (HD) to establish the usefulness of contrast enema as an initial screening and diagnostic tool. To correlate accuracy of radiological diagnosis at Grey’s Hospital with international standards.Materials and methods: Systematic searches were conducted through the Picture Archiving and Communication System and the National Health Laboratory Service records for patients aged 0–12 years, with clinically suspected HD, for whom both contrast enemas and rectal biopsies were performed between 01 January 2011 and 31 August 2015 in a tertiary-level hospital. A total of 54 such patients were identified. Diagnostic accuracy levels were calculated by comparing radiological results with histology results, which is the gold standard.Results: Diagnostic accuracy of contrast enema was 78%, sensitivity was 94.4% and the negative predictive value was 95.7%. Specificity (68.8%) and positive predictive values (63%) were considerably lower. A lower false-negative rate of 5.6% was obtained at Grey’s Hospital as compared with the international reports of up to 30%.Conclusion: Contrast enema remains useful as an initial screening and diagnostic test for HD. Results of this South African tertiary referral hospital were consistent with the best international results for sensitivity of the contrast enema (approximately 80% – 88% in excluding the disease).


2013 ◽  
Vol 31 (15_suppl) ◽  
pp. 1571-1571
Author(s):  
Goetz Geiges ◽  
Frank Koenig ◽  
Gerson Lüdecke ◽  

1571 Background: The open-access questionnaire RiskCheck Bladder Cancer (RCBC) was proven in daily routine work from German urologists organized in the health services research foundation IQUO on asymptomatic patients to identify BC risk exposure and its relation to detectable tumors. Methods: The open-access RCBC questionnaire checked asymptomatic patients for their BC risk exposure in relation to personal-, smoking-, occupation- and medical induced risk. This resulted in a risk stratification with low- intermediate- and high risk. The intermediate and high risk subjects were checked for tumor presence by routine diagnostics. IBM-SPSS 20 was used for descriptive statistics and effectiveness was proven by classification tree analysis and cross-table analysis with Chi-square test. Results: Out of 303 checked asymptomatic persons 274 (90.4%) were negative for tumor and 29 (9.6%) had a detectable tumor. In the group of NED 176 (68.1%) persons were classified as low risk, and 98 (16.2%) with tumor risk. Out of the 29 detected tumors 20 were at intermediate or high risk (68.9%). This resulted in an over all detection rate of 6.6% and focused on the risk population of 16.9%. The RCBC risk assessment was significant (p < 0.01). Sensitivity 69.0%, specificity 64.2%, NPV 95.1%, PPV 16.9%, false positive cases 35.8%, false negative cases 31.0%, accuracy 64.7%. Compared to the common incidence (35/100,000) this is an increase in effectiveness of 188.6 in the screened population and 482.8 in relation to the risk population alone. Conclusions: Preventive medical care becomes effective because RCBC is able to condense a population with focusing investigations on people living under risk. A reasonable preventive care by a yearly recall control in urological offices for the risk population (32.3%) can be organized. In consequence the assessment is work effective, aim achieving and in result cost effective. The questionnaire RCBC integrates evidence based bladder cancer inductors, is easy in use and as a open-access tool available in 10 languages via internet to all medical services. www.riskcheck-bladder-cancer.info.


Author(s):  
Richard Norris ◽  
Christian Kopkow ◽  
Michael James McNicholas

ObjectivesTo determine the accuracy of the dial test, used alone and in combination with additional clinical tests, in the diagnosis of an isolated posterolateral corner (PLC) injury, combined PLC-posterior cruciate ligament (PCL) injury or medial knee injury.MethodsA retrospective analysis of consecutive patients who underwent arthroscopic and/or open knee ligament reconstruction surgery was conducted. The dial test was performed in an outpatient’s clinic as part of a routine knee examination. Examination under anaesthetic and intraoperative findings were used as the reference standard test to determine the diagnostic accuracy of the dial test used alone and in combination with other PCL and medial knee tests. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+) and negative likelihood ratio (LR−) were calculated with corresponding 95% CI.ResultsData from 87 patients were available and included in the data analysis. For an isolated PLC injury, the dial test sensitivity and specificity were 0.20 (95% CI 0.08 to 0.39) and 1.00 (95% CI 0.92 to 1.00). The PPV and NPV were 1.00 (95% CI 0.52 to 1.00) and 0.70 (95% CI 0.59 to 0.80). LR+ and LR− of the dial test detecting isolated PLC injury were infinity (95% CI calculation not possible, infinity) and 0.80 (95% CI 0.41 to 1.57). The diagnostic accuracy of the dial test, when used alone and in combination with other PCL and medial knee tests, was also calculated for combined PLC-PCL and medial knee injuries.ConclusionA negative dial test at 30° of knee flexion can rule out a PLC injury, while a test that is positive at 30° and negative at 90° indicates a PLC injury, without concomitant injury to the PCL or medial knee ligaments. A positive test at both 30° and 90° can indicate isolated PLC, combined PLC-PCL or medial ligament injuries, and other knee examination findings are required to differentially diagnose these injury patterns.Level of evidenceII.


2021 ◽  
Author(s):  
Kun Li ◽  
Felix Young Jhonatan ◽  
Zhaohui Yu ◽  
Jinhua Chen ◽  
Lixin Huang ◽  
...  

Abstract Purpose To evaluate the diagnostic accuracy of a new modified MR dual precision positioning of thin-slice oblique sagittal fat suppression proton density-weighted imaging (DPP-TSO-Sag-FS-PDWI) sequence in detecting ACL injuries and its grades compared to standard sequences using arthroscopy as the standard reference.Materials and Methods 42 patients enrolled in this retrospective study received the 1.5-T MRI with standard sequences and the new modified DPP-TSO-Sag-FS-PDWI sequence, and their arthroscopy results was recorded. The Mc Nemer-Bowker and weighted Kappa was performed to compare the consistency of MRI diagnosis with arthroscopic results. Finally, the diagnostic accuracy was calculated based on the true positive, true negative, false negative and false positive values.Results The diagnostic consistency of the DPP-TSO-Sag-FS-PDWI were higher than standard sequences for both reader 1 (K = 0.876 vs. 0.620) and reader 2 (K = 0.833 vs. 0.683) with good diagnostic repeatability (K = 0.794 vs. 0.598). Furthermore, the DPP-TSO-Sag-FS-PDWI can classify and diagnose three grades of ACL injury [the sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value were more than 84%], especially for grade II injury as the PPV was superior for reader 1 (92.3% vs. 53.9%) and reader 2 (84.6% vs. 69.2%).Conclusion The new modified DPP-TSO-Sag-FS-PDWI sequence can display the ACL injury on one or continuous levels by maximizing the acquisition of complete ligament shape and true anatomical images, and excluding the influence of anatomical differences between individuals. It can improve the diagnostic accuracy with good repeatability and classify three grades of the ACL injury.


2021 ◽  
Author(s):  
Bokretsion Gidey ◽  
Desalegn Nega ◽  
Adugna Abera ◽  
Abnet Abebe ◽  
Sindew Mekasha ◽  
...  

Abstract Background: In Ethiopia, malaria cases are declining as a result of proven interventions and in 2017, the country launched a malaria elimination strategy in targeted settings. Accurate malaria diagnosis and prompt treatment are the key components of the strategy to prevent morbidity and stop the continuation of transmission. However, the quality of microscopic diagnosis in general is deteriorating as malaria burden declines. Therefore, this study was carried out to evaluate the competency of microscopists and the performance of health facilities on malaria microscopic diagnosis.Methods: A cross-sectional study was conducted from August 1st to September 30th, 2019 in nine regional states and one city administration. A standard checklist was used for on-site evaluation, archived patient slides were re-checked, and proficiency of microscopists was tested using WHO certified slides from the national slide bank at the Ethiopian Public Health Institute (EPHI). The strength of agreement, the sensitivity, the specificity, and the positive and negative predictive values were calculated.Results: In this study, 102 health facilities (84 health centers and 18 hospitals) were included; from which, 202 laboratory professionals participated. In slide re-checking, moderate agreement (Agreement: 76.0%; Kappa: 0.41) was observed between experts and microscopists on malaria detection in all health facilities. The sensitivity and specificity of routine slide reading and the re-checking results were 78.1% and 80.7%, respectively. Likewise, positive predictive value of 65.1% and negative predictive value of 88.8% were scored in the routine diagnosis. By panel testing, a substantial overall agreement (A: 91.8%; K: 0.79) was observed between microscopists and experts in detecting malaria parasites. The sensitivity and specificity in the detection of malaria parasites was 92.7% and 89.1%, respectively. Furthermore, in identifying species, a slight agreement (A: 57%; K: 0.18) was observed between microscopists and experts. Conclusion: The study found significant false positive and false negative results in routine microscopy on slide re-checking of Plasmodium parasites. Moreover, reduced grade in parasite species identification was reported on the panel tests. Therefore, implementing comprehensive malaria microscopy mentorship, in-service training, and supportive supervision are the key strategies to improve the overall performance of health facilities in malaria microscopy.


2018 ◽  
Vol 23 (3) ◽  
pp. 100-103
Author(s):  
Ajak Makor ◽  
Josephat Jombwe ◽  
Moses Galukande ◽  
Alex E. Elobu

Background: The management of acute appendicitis remains challenging with high peri-operative morbidity and mortality due diagnostic delay or high negative appendicetomy rates due to aggressive surgical approaches. CT scan is accurate for pre-operative diagnosis but not available or affordable in all settings. There remains a need for an affordable yet accurate tool for diagnosing acute appendicitis in the resource limited setting. Methods: To determine the diagnostic accuracy of Tzanakis score in the preoperative evaluation of patients with acute appendicitis, we conducted a descriptive cross-sectional study at Mulago Hospital in Kampala, Uganda. Eligible consenting patients diagnosed with acute appendicitis consecutively underwent Tzanakis scoring and appendicectomy. Appencieal samples were sent for histological examination. Sensitivity, specificity, positive predictive value, negative predictive values, and diagnostic accuracy of the Tzanakis scoring system were calculated, relative to histological examination. Results: We enrolled 160 participants of mean age 30.4 years with male:female ratio of 2:1. The Tzanakis score had sensitivity of100% (95% CI 98-100), positive predictive value 97 % (95% CI 95-99), specificity of 64% (95% CI 31-89), negative predictive value of 100%, and overall diagnostic accuracy of 98% with 3% negative appendectomy rate. Conclusions: The Tzanakis score is found to be a sensitive and specific tool that should be considered for preoperative diagnosis of acute appendicitis in resource limited settings. Keywords: appendicitis; appendicectomy; acute abdomen; diagnosis; Tzanakis score; Uganda 


Sign in / Sign up

Export Citation Format

Share Document