scholarly journals The Interchangeability of Plasma and Whole Blood Metal Ion Measurement in the Monitoring of Metal on Metal Hips

Arthritis ◽  
2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Ibrahim A. Malek ◽  
Joanne Rogers ◽  
Amanda Christina King ◽  
Juliet Clutton ◽  
Daniel Winson ◽  
...  

One hundred and twenty six paired samples of plasma and whole blood were measured with inductively coupled plasma mass spectrometry technique for metal ions analysis to determine a relationship between them. There was a significant difference between the mean plasma and whole blood concentrations of both cobalt (Co) and chromium (Cr) (p<0.0001 for both Co and Cr). The mean ratio between plasma and whole blood Cr and Co was 1.56 (range: 0.39–3.85) and 1.54 (range: 0.64–18.26), respectively, but Bland and Altman analysis illustrated that this relationship was not universal throughout the range of concentrations. There was higher variability at high concentrations for both ions. We conclude that both these concentrations should not be used interchangeably and conversion factors are unreliable due to concentration dependent variability.

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Wenfeng Xu ◽  
Shanshan Zhang ◽  
Wenqing Jiang ◽  
Shuo Xu ◽  
Pengfei Jin

Objective. To investigate the influence of gut microbiota on arsenic accumulation of realgar in mice. Methods. Mice were treated with antibiotics to form a mouse model of gut microbial disruption. Antibiotic-treated and normally raised mice were given 15 mg/kg, 150 mg/kg, and 750 mg/kg realgar by gavage and 0.2 mg/kg and 1 mg/kg arsenic solution by subcutaneous injection for 7 days. The concentration of arsenic in mice whole blood was determined by inductively coupled plasma mass spectrometry (ICP-MS). Arsenic accumulation in antibiotic-treated mice and normally raised mice was compared. Results. After exposure to low dose (15 mg/kg) and middle dose (150 mg/kg) of realgar, significantly, more arsenic was accumulated in the whole blood of antibiotic-treated mice compared to normally raised counterparts, which indicated that the disruption of gut microbiota could lead to higher arsenic load of realgar in mice. The homeostasis of gut microbiota was supposed to be disrupted by high dose (750 mg/kg) of realgar because after exposure to high dose of realgar, there was no significant difference in arsenic accumulation between antibiotic-treated and normally raised mice. Furthermore, arsenic solution was administered by subcutaneous injection to mice to investigate the influence of gut microbial differences on arsenic accumulation in addition to the absorption process, and there was no significant difference in arsenic accumulation between mice with these two different statuses of gut microbiota. Conclusions. Gut microbiota disruption could increase arsenic accumulation of realgar in mice.


Homeopathy ◽  
2018 ◽  
Vol 107 (04) ◽  
pp. 244-263 ◽  
Author(s):  
Martine Goyens ◽  
Etienne Capieaux ◽  
Philippe Devos ◽  
Pierre Dorfman ◽  
Michel Van Wassenhoven

Background Homeopathy is controversial due to its use of very highly diluted medicines (high potencies/dynamisations). Methods We used a multi-technology approach to examine dilutions of two commonly used homeopathic medicines: an insoluble metal, Cuprum metallicum, and a soluble plant tincture, Gelsemium sempervirens, for the presence of nanoparticles (NPs) of original substance. The homeopathic medicines tested were specially prepared, according to the European pharmacopoeia standards. We compared the homeopathic dilutions/dynamisations with simple dilutions and controls. Results Using Mass Spectrometry (Single Particle-Inductively Coupled Plasma-Mass Spectrometry) and Dynamic Light Scattering (DLS) we could not find the expected copper in the 4cH potentisation and could not confirm the results previously obtained by Chikramane et al (2010). For Gelsemium medicines, using sensitive chromatography (HPLC-UV) up to a dilution level of 6 dH (3cH = dilution 10e-6), there was no significant difference in alkaloid content between a simple dilution and a homeopathic potency.For higher potentisations, however, NP tracking analysis findings revealed the presence of particles in all samples (except for pure water). The measurements showed large differences in particle quantities, mean particle sizes and standard deviations of the mean sizes between manufacturing lines of different starting material.There was always more material in potentised medicines than in potentised pure water. Gelsemium yielded the largest quantity of material (36 times more than that from copper at the same potentisation, 30 cH). The shapes and the chemical composition of the material are differentiable between different medicines and controls. Conclusion Potentisation influences specifically the nature of NPs detected. This material demonstrates that the step-by-step process (dynamised or not) does not match with the theoretical expectations in a dilution process. The Avogadro/Loschmidt limit is not relevant at all. It was not possible to reproduce the findings of Chikramane et al (2010) using inductively coupled plasma-mass spectrometry with copper. Copper NPs could not be detected at 4cH and above.


2020 ◽  
Vol 83 (10) ◽  
pp. 1738-1744 ◽  
Author(s):  
JOMANA ELARIDI ◽  
HANI DIMASSI ◽  
MARIA ESTEPHAN ◽  
HUSSEIN F. HASSAN

ABSTRACT Infant formula is a major nutritional component for many infants and toddlers. However, the presence of contaminants, such as toxic metals, may pose increased health risks to infants. An investigation of the total concentrations of the metals aluminum (Al), barium (Ba), and chromium (Cr) in infant formulae marketed in Lebanon was performed. Powdered dairy and nondairy infant formula samples were collected from all commercially available brands (n = 39) in the Lebanese market on two production dates (78 samples in total) and analyzed for these three metals with inductively coupled plasma mass spectrometry. All brands contained detectable concentrations of Al and Ba, Cr was detected in 95% of brands. Mean (±standard deviation) concentrations of the metals were estimated as 1.54 ± 1.43 (Al), 0.256 ± 0.593 (Ba), and 0.168 ± 0.143 (Cr) (μg/g). The concentration ranges in the powdered formula were 0.080 to 7.93 (Al), 0.038 to 5.35 (Ba), and 0.041 to 0.348 (Cr) μg/g. A significant difference in the mean concentrations of Al, Ba, and Cr for the two production dates of a single brand was observed in 92, 59, and 83% of samples, respectively. The mean concentration of Al in the soy-based formula was significantly higher than that of aluminum in milk-based and corn-based formulas (P = 0.018). Cr concentrations in the continuation special formulations were significantly higher than those in the beginner formulations (P = 0.008). Our study provides the first publicly available information on metal contamination in infant formulas in Lebanon and reveals the need for frequent monitoring and surveillance of these products intended for infant consumption. HIGHLIGHTS


2021 ◽  
Vol 20 (2) ◽  
Author(s):  
Siti Hajjar Nasir ◽  
Muhammad Syahmi Mohamad Amran ◽  
Muhammad Muaz Abidin Mustaffar

INTRODUCTION: The growing demand for orthodontic braces among Malaysians has led to the development of fake braces. These fake braces services are illegal and their brackets are reported to be of inferior quality. Fake braces are constantly being exposed to the saliva intraorally, hence they are susceptible to corrosion. This study was conducted to investigate the release of metal ions as a result of corrosion from standard and fake orthodontic braces immersed in artificial saliva of different pH. MATERIALS AND METHODS: A total of six different types of brackets (three from standard and three from fake braces) were immersed in containers containing 5 mL of artificial saliva of pH 4.9 and pH 7.8. The samples were collected for analysis on day 1, day 14, and day 28 using Inductively-Coupled Plasma Mass Spectrometry (ICPMS) to evaluate the amount of metal ion released. Statistical analysis was performed to isolate the significant difference of metal ions released between two types of braces in different pH solutions. RESULTS: The release of aluminum, nickel, chromium, manganese and copper were observed and analyzed. Fake braces released the highest concentration of chromium, manganese, and nickel ions in both artificial saliva as compared to standard braces. Brackets immersed in pH 4.9 released a higher number of ions compared to pH 7.8. CONCLUSION: This study showed that fake braces released the highest concentration of metal ions as compared to standard braces. Both time and pH influenced the release of metal ions from orthodontic brackets.


2020 ◽  
Author(s):  
Emily Victoria Walker ◽  
Yuan Yuan ◽  
Safwat Girgis ◽  
Karen J. Goodman

Abstract Background: Methylmercury contamination of the environment represents a substantial environmental health concern. Human exposure to methylmercury occurs primarily through consumption of fish and marine mammals. Heavily exposed subgroups include sport or subsistence fishers residing in Arctic communities. We aimed to estimate the association of fish/whale consumption patterns of Canadian Arctic subsistence fishers with the internal dose of methylmercury as measured in hair. Methods: This research was conducted within ongoing community projects led by the CAN Help Working Group in Aklavik and Fort McPherson, Northwest Territories and Old Crow, Yukon. We interviewed each participant using a fish-focused food-frequency questionnaire during September-November 2016 and collected hair samples concurrently. Methylmercury was measured in the full-length of each hair sample using gas chromatography inductively-coupled plasma-mass spectrometry. Multivariable linear regression estimated beta-coefficients and 95% confidence intervals (CIs) for the effect of fish/whale consumption on hair-methylmercury concentrations. Results: Among 101 participants who provided hair samples and diet data, the mean number of fish/whale species eaten was 3.5 (SD:1.9). The mean hair-methylmercury concentration was 0.60μg/g (SD:0.47). Fish/whale consumption was positively associated with hair-methylmercury concentration, after adjusting for sex, hair length and use of permanent hair treatments. Hair-methylmercury concentrations among participants who consumed the most fish/whale in each season ranged from 0.30- 0.50μg/g higher than those who consumed <1 meal/week. Conclusions: In this population of Canadian Arctic subsistence fishers, hair-methylmercury concentration increased with fish/whale consumption, but the maximum concentrations were below Health Canada’s 6.0μg/g threshold for safe exposure.


2017 ◽  
Vol 1 (1) ◽  
pp. 97-107 ◽  
Author(s):  
A. Ademi ◽  
A. Bernhoft ◽  
E. Govasmark ◽  
H. Bytyqi ◽  
T. Sivertsen ◽  
...  

Abstract The aim of this study was to assess the concentration of Se and other minerals in sheep and the supplied feed. Four macrominerals (Ca, P, Mg, and S), 7 microminerals (Se, Fe, Zn, Cu, Mn, Co, and Mo), and 2 toxic minerals (Cd and Pb) were analyzed in 69 feed and 292 sheep blood samples from 30 farms in different regions of Kosovo. The samples were analyzed using inductively coupled plasma mass spectrometry, and mineral concentrations in whole blood were measured to assess their status in animals. Concentrations of the different minerals in feed were found in the following ranges: 1.9 to 9.5 g Ca/kg DM, 0.8 to 3.2 g P/kg DM, 0.8 to 3.2 g Mg/kg DM, 1.0 to 2.8 g S/kg DM, 6 to 82 µg Se/kg DM, 33 to 970 mg Fe/kg DM, 15 to 42 mg Zn/ kg DM, 2.6 to 7.5 mg Cu/kg DM, 26 to 250 mg Mn/kg DM, 0.04 to 0.88 mg Co/kg DM, 0.05 to 0.86 mg Mo/ kg DM, 0.07 to 2.02 mg Pb/kg DM, and 0.02 to 0.19 mg Cd/kg DM. Concentrations of the microminerals analyzed in whole blood were found in the following ranges: 15 to 360 µg Se/L, 190 to 500 mg Fe/L, 1.4 to 3.8 mg Zn/L, 0.3 to 2.6 mg Cu/L, 6 to 243 µg Mn/L, 0.1 to 19.6 µg Co/L, and 1.8 to 66.0 µg Pb/L. Among all minerals, the largest deficiency was found for Se both in feed and sheep blood, with 82% of feed samples and 83% blood samples being inadequate, and its supplementation is necessary. Selenium-supplemented sheep had significantly higher Se concentration in blood than non-supplemented sheep (P &lt; 0.01). In addition, other macro- and microminerals in feed such as P, S, Cu, and Co were at inadequate concentrations at some of the farms, and supplementation may also be needed for these minerals.


Animals ◽  
2019 ◽  
Vol 9 (7) ◽  
pp. 465 ◽  
Author(s):  
Diego Luna ◽  
Marta López-Alonso ◽  
Yolanda Cedeño ◽  
Lucas Rigueira ◽  
Víctor Pereira ◽  
...  

This study was designed to evaluate the influence of type of blood sample (serum or plasma) on essential and toxic element analysis in cattle. Paired plasma and serum samples (n = 20) were acid digested, and the concentrations of As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn. Mo, Ni, P, Pb, Sb, Se, Sr and Zn were determined by inductively coupled plasma mass spectrometry (ICP-MS). The study findings indicate that plasma and serum samples appear suitable and interchangeable for the determination of most of the essential and toxic elements in blood in cattle. The only exceptions are Cu and Se, the concentrations of which were significantly lower (40.9 and 29.9% respectively) in serum than in plasma. Some of the Cu in blood samples from bovine ruminants is known to be sequestered during clotting. However, further research on Se in ruminants and other animal species is warranted. Finally, the significantly higher Mn (9.9%) concentrations in serum than in plasma may have been caused by haemolysis of some samples. Special attention should be paid to preventing haemolysis of samples during collection and processing, in order to prevent overestimation of elements present at high concentrations inside erythrocytes (i.e., Fe, Mn and Zn).


Sign in / Sign up

Export Citation Format

Share Document