scholarly journals Transcrestal Sinus Lift Procedure Approaching Atrophic Maxillary Ridge: A 60-Month Clinical and Radiological Follow-Up Evaluation

2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
G. Lo Giudice ◽  
G. Iannello ◽  
A. Terranova ◽  
R. Lo Giudice ◽  
G. Pantaleo ◽  
...  

Aim.The aim of this study was to assess the success and the survival rate of dental implants placed in augmented bone after sinus lifting procedures.Material and Methods.31 patients were mainly enrolled for a residual upper jaw crest thickness of 3 mm. CBCT scans were performed before and after the augmentation technique and at the follow-up appointments, at 3, 6, 12, 24, and up to 60 months. The follow-up examination included cumulative survival rate of implants, peri-implant marginal bone loss, and the height of sinus floor augmentation.Results.This retrospective study on 31 patients and 45 implants later inserted in a less than 3 mm crest showed excellent survival rates (99.5%), one implant was lost before loading due to an acute infection after 24 days, and two implants did not osteointegrate and were removed after 3 months. The radiological evaluation showed an average bone loss of 0.25 mm (±0.78 mm) at the first follow-up appointment (3 months) up to 0.30 mm (±1.28 mm) after 60-month follow-up.Conclusion.In this study it was reported how even in less than 3 mm thick crest a transcrestal technique can predictably be used with a long-term clinical and radiological outcome, giving patients excellent stability of the grafted material and healthy clinical results.

Materials ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1029 ◽  
Author(s):  
Pietro Montemezzi ◽  
Francesco Ferrini ◽  
Giuseppe Pantaleo ◽  
Enrico Gherlone ◽  
Paolo Capparè

The present study was conducted to investigate whether a different implant neck design could affect survival rate and peri-implant tissue health in a cohort of disease-free partially edentulous patients in the molar–premolar region. The investigation was conducted on 122 dental implants inserted in 97 patients divided into two groups: Group A (rough wide-neck implants) vs. Group B (rough reduced-neck implants). All patients were monitored through clinical and radiological checkups. Survival rate, probing depth, and marginal bone loss were assessed at 12- and 24-month follow-ups. Patients assigned to Group A received 59 implants, while patients assigned to Group B 63. Dental implants were placed by following a delayed loading protocol, and cemented metal–ceramic crowns were delivered to the patients. The survival rates for both Group A and B were acceptable and similar at the two-year follow-up (96.61% vs. 95.82%). Probing depth and marginal bone loss tended to increase over time (follow-up: t1 = 12 vs. t2 = 24 months) in both groups of patients. Probing depth (p = 0.015) and bone loss (p = 0.001) were significantly lower in Group A (3.01 vs. 3.23 mm and 0.92 vs. 1.06 mm; Group A vs. Group B). Within the limitations of the present study, patients with rough wide-neck implants showed less marginal bone loss and minor probing depth, as compared to rough reduced-neck implants placed in the molar–premolar region. These results might be further replicated through longer-term trials, as well as comparisons between more collar configurations (e.g., straight vs. reduced vs. wide collars).


2016 ◽  
Vol 10 (1) ◽  
pp. 680-691 ◽  
Author(s):  
Jakob Zwaan ◽  
Leonardo Vanden Bogaerde ◽  
Herman Sahlin ◽  
Lars Sennerby

Purpose: To study the clinical/radiographic outcomes and stability of a tapered implant design with a hydrophilic surface when placed in the maxilla using various protocols and followed for one year. Methods: Ninety-seven consecutive patients treated as part of daily routine in two clinics with 163 tapered implants in healed sites, in extraction sockets and together with bone augmentation procedures in the maxilla were evaluated after one year in function. Individual healing periods varying from 0 to 6 months had been used. Insertion torque (IT) and resonance frequency analysis (RFA) measurements were made at baseline. Follow-up RFA registrations were made after 6 and 12 months of loading. The marginal bone levels were measured in intraoral radiographs from baseline and after 12 months. A reference group consisting of 163 consecutive straight maxillary implants was used for the comparison of baseline IT and RFA measurements. Results: Five implants failed before loading, giving an implant survival rate of 96.9% and a prosthesis survival rate of 99.4% after one year. The mean marginal bone loss after one year was 0.5 mm (SD 0.4). The mean IT was statistically significantly higher for tapered than for straight reference implants (41.3 ± 12.0 Ncm vs 33.6 ± 12.5 Ncm, p < 0.001). The tapered implants showed a statistically insignificantly higher mean ISQ value than the straight references implants (73.7 ± 6.4 ISQ vs 72.2 ± 8.0 ISQ, p=0.119). There was no correlation between IT and marginal bone loss. There was a correlation between IT and RFA measurements (p < 0.001). Conclusion: The tapered implant showed a high survival rate and minimal marginal bone loss after one year in function when using various protocols for placement. The tapered implant showed significantly higher insertion torque values than straight reference implants.


2020 ◽  
Vol 10 (23) ◽  
pp. 8709
Author(s):  
Diego Lops ◽  
Riccardo Guazzo ◽  
Alessandro Rossi ◽  
Antonino Palazzolo ◽  
Vittorio Favero ◽  
...  

The aim of the present investigation is to evaluate the implant therapy outcomes over a period of 5 years and to analyze several patient risk factors influencing the stability of the peri-implant tissues. Seventy-eight patients were consecutively treated between 2009 and 2017 and restored with implant-supported fixed prostheses. The following inclusion criteria were considered: partial or complete edentulism; residual bone volume of at least 3.3 mm in diameter and 8 mm in length; a favorable relationship between maxilla and mandible; at least a minimum 5 year follow-up for each implant included in the statistical analysis. Intraoral radiographs were taken at implant loading and every 12 months during the follow-up visits. They were subsequently stored on a personal computer and analyzed to determine the changes in bone level. Seventy-eight patients receiving 209 implants completed a minimum follow-up period of 5 years. One-hundred dental implants were inserted in the maxilla while 109 were placed in the mandible. Eleven (14.1%) out of 78 treated patients who received 29 (13.9%) dental implants were considered as drop-outs. On the whole, peri-implantitis was diagnosed in three implants. The average final pocket probing depth at implant level was 2.5 ± 1.2 mm. The average final bone loss after 5 years was 0.3 ± 0.4 mm, both at the mesial and distal aspect of the implant. The effects of the prosthesis type, sex and implant site did not statistically influence the marginal bone loss; on the contrary, a statistically significant difference regarding marginal bone loss was detected between smoker and non-smoker patients (p = 0.021). Implants with internal-conical abutment connection showed stable peri-implant bone levels at the medium-term follow-up. Nevertheless, further prospective long-term clinical studies are necessary to confirm these data.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
B. Alper Gultekin ◽  
Ali Sirali ◽  
Pinar Gultekin ◽  
Serdar Yalcin ◽  
Eitan Mijiritsky

Purpose. To compare marginal bone loss between subgingivally placed short-collar implants with machined collars and those with machined and laser-microtextured collars.Materials and Methods. The investigators used a retrospective study design and included patients who needed missing posterior teeth replaced with implants. Short-collar implants with identical geometries were divided into two groups: an M group, machined collar; and an L group, machined and laser-microtextured collar. Implants were evaluated according to marginal bone loss, implant success, and probing depth (PD) at 3 years of follow-up.Results. Sixty-two patients received 103 implants (56 in the M group and 47 in the L group). The cumulative survival rate was 100%. All implants showed clinically acceptable marginal bone loss, although bone resorption was lower in the L group (0.49 mm) than in the M group (1.38 mm) at 3 years (p<0.01). A significantly shallower PD was found for the implants in the L group during follow-up (p<0.01).Conclusions. Our results suggest predictable outcomes with regard to bone loss for both groups; however, bone resorption was less in the L group than in the M group before and after loading. The laser-microtextured collar implant may provide a shallower PD than the machined collar implant.


Medicina ◽  
2021 ◽  
Vol 58 (1) ◽  
pp. 10
Author(s):  
Tommaso Grandi ◽  
Luca Signorini

(1) Background and Objectives. Currently, there are no definitive long-term data about clinically significant difference in the failure of prosthesis and implant or marginal bone loss related to the rehabilitation of the completely edentulous mandible by all-on-four treatment concept. The main aim of present investigation was to report the long-term outcomes (10-years follow-up) of complete-arch mandibular rehabilitations based on the all-on-four concept. (2) Materials and Methods. Patients in need of extractions of teeth due to the occurrence of caries and/or severe periodontal disease and patients presented with edentulous mandibles were enrolled to the study. A total of 96 participants (mean follow-up period after intervention of 3185.2 days) were enrolled in the study. Participants were evaluated at the first visit, 10 days after intervention and every year after the intervention. Implant and prosthesis survival, bone loss and both local biological and mechanical complications were evaluated during the follow-up period. (3) Results. An implants’ survival rate of 97.9% was observed at the end of the follow-up period. Biological complications were reported in 19.8% of patients, whereas mechanical complications were reported in 27.1% of cases. The average marginal bone level at baseline was −0.03 mm. A significant marginal bone loss was observed after 10-years follow-up (2.5 mm). Binary logistic regression analysis showed significant association between smoke and both marginal bone loss and local biological complications. Lastly, a significant association was observed between bruxism and mechanical complications. (4) Conclusions. The high implant and prosthesis survival rate and the moderate incidence of biological and mechanical complications observed in present investigation can be associated to several factors such as high implant primary stability, prosthetic design, and control of the occlusal forces.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
S. Storelli ◽  
A. Caputo ◽  
G. Palandrani ◽  
M. Peditto ◽  
M. Del Fabbro ◽  
...  

Objective. The objective of the present review is to assess the implant survival, marginal bone loss, and biomechanical features of narrow-diameter implants (2.5-3.5 mm) supporting or retaining full-arch fixed or removable restorations. Materials and Methods. Three operators screened the literature (PubMed, Cochrane Library, and Google Scholar) and performed a hand search on the main journals that focus on implantology until 24 March 2019. Only articles that considered full-arch restorations supported or retained by narrow-diameter implants (2.5-3.5 mm) were considered if they have a minimum of 10 patients and a mean follow-up of at least 6 months. The outcome variables were survival of implants and marginal bone loss. The review was performed according to the PRISMA statements. Risk of bias assessment was evaluated. Failure rates were analyzed using random effect Poisson regression models to obtain the summary estimate of 5-year survival rate and marginal bone loss. Results. A total of nine papers were finally selected, reporting a high survival rate of the implants. Eight studies focused only on the mandible while one study reported data from both mandible and maxilla. All studies reported on removable restorations; none focused on fixed rehabilitations. The estimated survival rate for 5 years of follow-up was calculated to be 92.25% for the implants. The estimated marginal bone loss after 5 years was calculated to be 1.40 mm. No study reported implant fractures. Conclusions. With the limitations of the present study, there is evidence that 2.5-3.5 mm narrow-diameter implants retaining a removable restoration can be a successful treatment in fully edentulous patients. No data on fixed restorations was available.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Enrico F. Gherlone ◽  
Gianpaolo Sannino ◽  
Andrea Rapanelli ◽  
Roberto Crespi ◽  
Giorgio Gastaldi ◽  
...  

Objectives. The aim of this clinical study was to evaluate a new type of prefabricated bar system, supported by axial and tilted implants at 5-year follow-up. Materials and Methods. Twenty-nine consecutive participants (19 females, 10 males) (mean age 61.4 years), edentulous in one or both jaws, with severe atrophy of the posterior regions, were treated according to the All-on-four® protocol with immediately loaded axial (64) and tilted (64) implants supporting complete-arch screw-retained prostheses (12 maxillary, 20 mandibular) featuring a prefabricated bar as framework. Follow-up visits were performed at 3, 6, 12, 24, 48, and 60 months after implant insertion. Radiographic assessments were made using panoramic radiographs obtained immediately after surgery and at each follow-up visit. Bone level measurements around the axial and tilted implants were compared by means of the Student’s t-test. Results. One axial implant failed in the lower jaw and did not compromise prosthetic function. The 60-month overall implant survival rate was 100% for axially positioned implants and 98.44% for tilted implants. The implant survival rates were 100% in the maxilla and 98.75% in the mandible. None of the 32 fixed prostheses were lost during the observation period, representing a prosthetic survival rate of 100%. No statistically significant differences (P>0.05) in marginal bone loss between tilted and axial implants were detected in either jaw over time. Conclusions. The use of the evaluated prefabricated bar for immediately loaded implants placed according to the All-on-four concept may significantly reduce implant failures; however, more long-term prospective clinical trials are needed to affirm the effectiveness of the surgical-prosthetic protocol.


Author(s):  
Saverio Cosola ◽  
Simone Marconcini ◽  
Michela Boccuzzi ◽  
Giovanni Battista Menchini Fabris ◽  
Ugo Covani ◽  
...  

Background: to assess the radiological marginal bone loss between bone-level or tissue-level dental implants through a systematic review of literature until September 2019. Methods: MEDLINE, Embase and other database were searched by two independent authors including only English articles. Results: The search provided 1028 records and, after removing the duplicates through titles and abstracts screening, 45 full-text articles were assessed for eligibility. For qualitative analysis 20 articles were included, 17 articles of them for quantitative analysis counting a total of 1161 patients (mean age 54.4 years) and 2933 implants, 1427 inserted at Tissue-level (TL) and 1506 inserted at Bone-level (BL). The survival rate and the success rate were more than 90%, except for 2 studies with a success rate of 88% and 86.2%. No studies reported any differences between groups in term of success and survival rates. Three studies showed that BL-implants had statistically less marginal bone loss (p < 0.05). Only one study reported statistically less marginal bone loss in TL-implants (p < 0.05). Conclusion: In the most part of the studies, differences between implant types in marginal bone loss were not statistically significant after a variable period of follow-up ranged between 1 and 5 years.


2016 ◽  
Vol 27 (3) ◽  
pp. 292-297 ◽  
Author(s):  
Clarissa D. Koller ◽  
Tatiana Pereira-Cenci ◽  
Noéli Boscato

Abstract This study evaluated retrospectively the association among occlusal, periodontal and implant-prosthetic parameters and marginal bone loss (MBL) around implants and survival rate at 5.7 ±3.2 years of follow-up after prosthetic loading. Eighty-two patients received 164 external hexagon implants. After the standard healing period (3 to 6 months), the implants were restored with single-tooth or up to three splinted crowns. All patients were followed according to a strict maintenance program with regular recalls and clinically evaluated by a calibrated examiner. The MBL measurements taken from standardized radiographs made at permanent crown placement (baseline) and after the last evaluation were calculated considering occlusal, periodontal and implant-prosthetic parameters. Veneer fractures and abutment loosening were not considered failure. Two implants failed during the follow-up period, resulting in a survival rate of 98.8%. Cox regression analyses showed MBL associated with non-working side contacts (p=0.047), inadequate anterior guidance (p=0.001), lateral group guidance involving teeth and implants (p=0.015), periimplant plaque index (p=0.035), prosthetic design (p=0.030) and retention (p=0.006). Inadequate occlusal pattern guide, presence of visible plaque, and cemented and splinted implant-supported restoration were associated with greater MBL around the implant.


Sign in / Sign up

Export Citation Format

Share Document