scholarly journals Turbulent Forced Convection and Heat Transfer Characteristic in a Circular Tube with Modified-Twisted Tapes

2016 ◽  
Vol 2016 ◽  
pp. 1-16 ◽  
Author(s):  
Amnart Boonloi ◽  
Withada Jedsadaratanachai

Heat transfer, pressure loss, and thermal performance assessment in a circular tube heat exchanger with modified-twisted tapes are reported. The rectangular holes are punched out from the general twisted tape to reduce the pressure loss. The influences of the hole sizes (l/D, LR = 0.30, 0.44, 0.78, and 0.88) and twisted ratios (y/D, TR = 1, 1.5, 2, and 4) for the single and double twisted tapes are investigated with a numerical method at turbulent regime, Re = 3000–10,000. The finite volume method and the SIMPLE algorithm are used to investigate for the current research. The numerical results are reported in terms of flow structure and heat transfer behavior and compared with the smooth tube and the regular twisted tape. It is found that the modified-twisted tape provides higher heat transfer rate than the smooth tube due to the longitudinal vortex flows, created by the twisted tape. The longitudinal vortex flows help to increase fluid mixing. The rectangular punched holes of the twisted tape can reduce the pressure loss of the heating system. In addition, the maximum thermal enhancement factor is around 1.39 and 1.31 for the double twisted tape and single twisted tape, respectively, at Re = 3000, LR = 0.78, and TR = 1.

Author(s):  
R. J. Yadav ◽  
Sandeep Kore ◽  
V. N. Riabhole

Heat transfer and pressure drop characteristics in a circular tube with twisted tapes have been investigated experimentally and numerically using different working fluids by many researchers for wide range of Reynolds number. The swirl was generated by tape inserts of various twist ratios. The various twist ratios are considered Many researchers formed generalized correlations to predict friction factors and convective heat transfer coefficients with twisted tapes in a tube for a wide range of Reynolds numbers and Prandtl numbers. Satisfactory agreement was obtained between the present correlations and the data of others validate the proposed correlations. The experimental or numerical predictions were compared with earlier correlations revealing good agreement between them. From the literature review it is observed that most studies are mainly focused on the heat transfer enhancement using twisted tape by experimental or numerical solution. An investigation with analytical approach is rarely reported. Therefore, the main aim of the present work is to form a correlation from theoretical approach for Nusselt number for circular tube with twisted tape. Application of dimensional analysis to heat transfer in tape generated swirl flow is carried out.


2001 ◽  
Vol 123 (3) ◽  
pp. 417-427 ◽  
Author(s):  
S. K. Saha ◽  
A. Dutta

Heat transfer and pressure drop characteristics in a circular tube fitted with twisted tapes have been investigated experimentally. Laminar swirl flow of a large Prandtl number 205<Pr<518 viscous fluid was considered. The swirl was generated by short-length twisted-tape inserts; regularly spaced twisted-tape elements with multiple twists in the tape module and connected by thin circular rods; and smoothly varying (gradually decreasing) pitch twisted-tapes. The heat transfer test section was heated electrically imposing axially and circumferentially constant wall heat flux (UHF) boundary condition. Reynolds number, Prandtl number, twist ratio, space ratio, number of tuns in the tape module, length of the twisted-tape and smoothness of the swirling pitch govern the characteristics. Friction factor and Nusselt number are lower for short-length twisted-tape than those for full-length twisted-tape. On the basis of constant pumping power and constant heat duty, however, short-length twisted-tapes are found to perform better than full-length twisted-tapes for tighter twists. Thermohydraulic performance shows that twisted-tapes with multiple twists in the tape module is not much different from that with single twist in the tape module. Friction factor and Nusselt number are approximately 15 percent lower for twisted-tapes with smooth swirl having the average pitch same as that of the uniform pitch (throughout) twisted-tape and the twisted-tapes with gradually decreasing pitch perform worse than their uniform-pitch counterparts.


2012 ◽  
Vol 2012 ◽  
pp. 1-12 ◽  
Author(s):  
R. J. Yadav ◽  
A. S. Padalkar

CFD investigation was carried out to study the heat transfer enhancement characteristics of air flow inside a circular tube with a partially decaying and partly swirl flow. Four combinations of tube with twisted-tape inserts, the half-length upstream twisted-tape condition (HLUTT), the half-length downstream twisted-tape condition (HLDTT), the full-length twisted tape (FLTT), and the plain tube (PT) with three different twist parameters (, 0.27, and 0.38) have been investigated. 3D numerical simulation was performed for an analysis of heat transfer enhancement and fluid flow for turbulent regime. The results of CFD investigations of heat transfer and friction characteristics are presented for the FLTT, HLUTT, and the HLDTT in comparison with the PT case.


2017 ◽  
Vol 2017 ◽  
pp. 1-20 ◽  
Author(s):  
Withada Jedsadaratanachai ◽  
Amnart Boonloi

Performance assessments on heat transfer, pressure loss, and thermal enhancement factor in the circular tube heat exchanger inserted with the V-orifices are investigated numerically. The influences of the blockage ratio, gap spacing ratio, and orifice arrangement are reported for turbulent regime, Re=3000–10,000. The finite volume method and SIMPLE algorithm are selected to solve the present problem. The mechanisms on flow and heat transfer characteristics are described. The periodic concepts on flow and heat transfer are also studied. The numerical results show that the gap spacing ratio is main reason for the changes of the flow and heat transfer topologies. The gap distance helps to adjust the optimum point of the thermal performance, especially at high flow blockage ratio. In addition, the optimum thermal performance of the present system is around 2.25 at the lowest Reynolds number, Re=3000.


2020 ◽  
Author(s):  
Li Wang ◽  
Peiyong Ni ◽  
Guannan Xi

Abstract This study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The numerical analysis of the flow field, average Nusselt number, friction factor and thermo-hydraulic performance parameter of the tube are discussed with Reynolds number ranged from 2600 to 8760. The results indicate that the Nusselt number of the tube fitted with center-placed twisted tapes at various width is 7~51% higher than the plain tube, and performance in low Reynolds region was found more effective than that in high Reynolds region. The heat transfer for circular tube with twisted tape attached to the wall shows better performance than that for the tube with center-placed twisted tape. With a smaller tape width, a higher increasing ratio of Nu-wall/Nu-center is obtained. The increasing ratio for Nusselt number ranged from 3 to 18%. However, the use of twisted tape inserts is not beneficial for energy saving. The thermo-hydraulic performance parameters for convective heat transfer of helium gas flowing in a circular tube are below unity for the calculated Reynolds region.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Li Wang ◽  
Peiyong Ni ◽  
Guannan Xi

AbstractThis study is conducted to investigate the effect of off-center placement of twisted tape on flow distribution and heat transfer in a circular tube. The effect of tape width of 20, 18, 16, 14 and 12 mm on the heat transfer performance is discussed under the same twist ratio of 2.0. The numerical analysis of the flow field, average Nusselt number, friction factor and thermo-hydraulic performance parameter of the tube are discussed with Reynolds number ranged from 2600 to 8760. The results indicate that the Nusselt number of the tube fitted with center-placed twisted tapes at various width is 7–51% higher than the plain tube, and performance in low Reynolds region was found more effective than that in high Reynolds region. The heat transfer for circular tube with twisted tape attached to the wall shows better performance than that for the tube with center-placed twisted tape. With a smaller tape width, a higher increasing ratio of Nu-wall/Nu-center is obtained. The increasing ratio for Nusselt number ranged from 3 to 18%. However, the use of twisted tape inserts is not beneficial for energy saving. The thermo-hydraulic performance parameters for convective heat transfer of helium gas flowing in a circular tube are below unity for the calculated Reynolds region.


Nanomaterials ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1656 ◽  
Author(s):  
Mehdi Ghalambaz ◽  
Hossein Arasteh ◽  
Ramin Mashayekhi ◽  
Amir Keshmiri ◽  
Pouyan Talebizadehsardari ◽  
...  

This study investigated the laminar convective heat transfer and fluid flow of Al2O3 nanofluid in a counter flow double-pipe heat exchanger equipped with overlapped twisted tape inserts in both inner and outer tubes. Two models of the same (co-swirling twisted tapes) and opposite (counter-swirling twisted tapes) angular directions for the stationary twisted tapes were considered. The computational fluid dynamic simulations were conducted through varying the design parameters, including the angular direction of twisted tape inserts, nanofluid volume concentration, and Reynolds number. It was found that inserting the overlapped twisted tapes in the heat exchanger significantly increases the thermal performance as well as the friction factor compared with the plain heat exchanger. The results indicate that models of co-swirling twisted tapes and counter-swirling twisted tapes increase the average Nusselt number by almost 35.2–66.2% and 42.1–68.7% over the Reynolds number ranging 250–1000, respectively. To assess the interplay between heat transfer enhancement and pressure loss penalty, the dimensionless number of performance evaluation criterion was calculated for all the captured configurations. Ultimately, the highest value of performance evaluation criterion is equal to 1.40 and 1.26 at inner and outer tubes at the Reynolds number of 1000 and the volume fraction of 3% in the case of counter-swirling twisted tapes model.


2006 ◽  
Vol 128 (10) ◽  
pp. 1070-1080 ◽  
Author(s):  
Debashis Pramanik ◽  
Sujoy K. Saha

The heat transfer and the pressure drop characteristics of laminar flow of viscous oil through rectangular and square ducts with internal transverse rib turbulators on two opposite surfaces of the ducts and fitted with twisted tapes have been studied experimentally. The tapes have been full length, short length, and regularly spaced types. The transverse ribs in combination with full-length twisted tapes have been found to perform better than either ribs or twisted tapes acting alone. The heat transfer and the pressure drop measurements have been taken in separate test sections. Heat transfer tests were carried out in electrically heated stainless steel ducts incorporating uniform wall heat flux boundary conditions. Pressure drop tests were carried out in acrylic ducts. The flow was periodically fully developed in the regularly spaced twisted-tape elements case and decaying swirl flow in the short-length twisted tapes case. The flow characteristics are governed by twist ratio, space ratio, and length of twisted tape, Reynolds number, Prandtl number, rod-to-tube diameter ratio, duct aspect ratio, rib height, and rib spacing. Correlations developed for friction factor and Nusselt number have predicted the experimental data satisfactorily. The performance of the geometry under investigation has been evaluated. It has been found that on the basis of both constant pumping power and constant heat duty, the regularly spaced twisted-tape elements in specific cases perform marginally better than their full-length counterparts. However, the short-length twisted-tape performance is worse than the full-length twisted tapes. Therefore, full-length twisted tapes and regularly spaced twisted-tape elements in combination with transverse ribs are recommended for laminar flows. However, the short-length twisted tapes are not recommended.


Sign in / Sign up

Export Citation Format

Share Document