scholarly journals Simplified Material Solution for Orthotropic Symmetrical GFRP Laminates for Structural Facades

2019 ◽  
Vol 2019 ◽  
pp. 1-15
Author(s):  
Yuchao Zhao ◽  
Xu Jiang ◽  
Qilin Zhang ◽  
Xuhong Qiang

GFRP (glass-fiber-reinforced polymer), as a composite material, possesses many favorable properties including high strength and low weight and is amenable to unique processing methods; therefore, it is a potential free-form surface material. However, the complex design theory owing to anisotropy limits its application. Thus, a simplified material solution becomes significant. In this study, the strength and stiffness of orthotropic symmetrical GFRP laminates are derived theoretically, and a simplified material solution is proposed to simplify the anisotropy as isotropy. Then, using the numerical simulation of an actual orthotropic symmetrical GFRP laminate free-form facade structure, the effectiveness of the simplified material solution is analyzed and evaluated. This solution can provide guidance for similar GFRP facades and further promote the application of GFRP in engineering.

2012 ◽  
Vol 238 ◽  
pp. 669-673 ◽  
Author(s):  
Ying Hao Liu ◽  
Yong Yuan

The paper analyzes the structural behavior of high strength concrete (HSC) beams reinforced with hybrid glass fiber reinforced polymer (GFRP) and steel reinforcements. The analysis refers to HSC beams reinforced with GFRP rebars and steel rebars placed in different layers. Results of the experimental and theoretical investigation are represented and discussed. Significant features of the structural behavior regarding flexural strength, deflection, are pointed out.


2007 ◽  
Vol 345-346 ◽  
pp. 1217-1220
Author(s):  
Jung Yoon Lee

The use of fiber reinforced polymer (FRP) bars has been gaining increasing popularity in the civil engineering community due to their favorable properties such as high-strength-to-weight ratio and good corrosion resistance. In order for concrete to be FRP reinforced, there must be interfacial bond between FRP bars and concrete. The interfacial bond behavior of FRP bars to concrete is expected to vary from that of conventional steel bars, since various key parameters that influence bond performance are different. This paper presents the results of an experimental and analytical study on the interfacial surface interaction of glass fiber reinforced polymer (GFRP) bars in high strength concrete cube. The experimental program consisted of testing 54 concrete cubes prepared according to CSA S802-02 standard 1). The split specimens showed that interfacial bond failure of the steel bar occurred due to concrete crushing in front of the bar deformations, while interfacial bond failure of the GFRP bars occurred partly on the surface of the bar and partly in the concrete by peeling of the surface layer of the bar.


1994 ◽  
Vol 116 (3) ◽  
pp. 167-172 ◽  
Author(s):  
P. K. Dutta

Polymeric composites are relatively inexpensive materials of high strength, in which deformation of the matrix is used to transfer stress by means of shear traction at the fiber-matrix interface to the embedded high-strength fibers. At low temperatures, complex stresses are set up within the microstructure of the material as a result of matrix stiffening and mismatch of thermal expansion coefficients of the constituents of the composites. These stresses in turn affect the strength and deformation characteristics of the composites. This is demonstrated by compression testing of an unidirectional glass-fiber-reinforced polymer composite at room and low temperatures. The increase of compressive strength matched the analytical prediction of strength increase modeled from the consideration of increase in matrix stiffness and thermal residual stresses at low temperatures. Additional compression tests performed on a batch of low-temperature thermally cycled specimens confirmed the predictable reduction of brittleness due to suspected increase of microcrack density. The mode of failure characterized by definite pre-fracture yielding conforms more to Budiansky’s plastic microbuckling theory than to Rosen’s theory of elastic shear or extensional buckling.


2015 ◽  
Vol 76 (9) ◽  
Author(s):  
Norazean Shaari ◽  
Aidah Jumahat ◽  
Shahrul Azam Abdullah ◽  
Ahmad Zariff Hadderi

Hybrid laminates consisting of woven Kevlar/glass fiber composite plies were studied in terms of their residual tensile strength, stiffness and fracture surface.  Residual tensile strength and stiffness were determined from the open hole tension test according to ASTM D5766. The laminates of Kevlar fiber reinforced polymer (KFRP), glass fiber reinforced polymer (GFRP) and hybrid of Kevlar-glass fiber reinforced polymer (KGFRP) were fabricated using a vacuum bagging process. Three different ratios of Kevlar to glass fiber plies were prepared in this study which were 20:80, 50:50, and 80:20. Results showed that hybrid laminate consisting of 80:20 Kevlar to glass fiber plies, produced higher residual tensile strength and stiffness when compared to the other hybrid system. Furthermore, strength and stiffness of hole specimens were reduced within 50-63% when compared to unhole specimens due to existence of the hole. In addition, the effect of adding nanosilica to the hybrid system was also studied. 5 wt% of nanosilica was added to the hybrid composite laminates and results showed that higher tensile strength and stiffness was observed in GFRP and 20:80 KGFRP specimens, while the tensile strength was decreased with an increased number of Kevlar fiber. This research was conducted as there are limited number of studies that have been done on the tensile strength of woven hybrid composite laminates so far, especially on hybridization of Kevlar and glass fiber with consideration on the effect of hole and addition of nanofillers.


2016 ◽  
Vol 20 (3) ◽  
pp. 374-393 ◽  
Author(s):  
Le Zhou ◽  
Lianguang Wang ◽  
Liang Zong ◽  
Gang Shi ◽  
Yunhao Bai ◽  
...  

Glass fiber–reinforced polymer tubes filled with steel-reinforced high-strength concrete are proposed as glass fiber–reinforced polymer–steel-reinforced high-strength concrete composite members. Eccentric compression is a typical loading scenario for such column members in practice. Experimental investigation on eight glass fiber–reinforced polymer tubes filled with steel–reinforced high-strength concrete columns subjected to eccentric compression was conducted. The effects of fiber orientation, thickness of glass fiber–reinforced polymer tube, slenderness ratio of columns, and loading eccentricity were investigated. It was found that the compression bearing capacity of glass fiber–reinforced polymer–steel-reinforced high-strength concrete columns increased with the decrease in the fiber tangle angle and the increase in the thickness of the glass fiber–reinforced polymer tube but reduced with the increase in the eccentricity and the slenderness ratio. Corresponding formulas were developed based on the nonlinear full-process analysis theory to describe the compression behavior of glass fiber–reinforced polymer–steel-reinforced high-strength concrete under eccentric loading. Good agreement was found through the comparison between the theoretical and the experimental results. The validated modeling approach was, therefore, employed to develop a parametric analysis that can be used to provide valuable guidance for practical application and further research on such structural members.


Sign in / Sign up

Export Citation Format

Share Document