scholarly journals Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone

2019 ◽  
Vol 2019 ◽  
pp. 1-13 ◽  
Author(s):  
Noman Q. Al-Naggar ◽  
Husam Mohammed Al-Hammadi ◽  
Adel Mohammed Al-Fusail ◽  
Zakarya Ali AL-Shaebi

Background. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, blood oxygen saturation, and temperature) based on smartphones, considering high performance, autoalarm generation, warning transmission, and security through more than one method. Methods. Data on monitoring parameters were acquired by the integrated circuits of wearable sensors and collected by an Arduino Mega 250 R3. The collected data were transmitted via a Wi-Fi interface to a smartphone. A patient application was developed to analyze, process, and display the data in numerical and graphical forms. The abnormality threshold values of parameters were identified and analyzed to generate an autoalarm in the system and transmitted with data to a doctor application via a third-generation (3G) mobile network and Wi-Fi. The performance of the proposed system was verified and evaluated. The proposed system was designed to meet main (sensing, processing, displaying, real-time transmission, autoalarm generation, and threshold value identification) and auxiliary requirements (compatibility, comfort, low power consumption and cost, small size, and suitability for ambulatory applications). Results. System performance is reliable, with a sufficient average accuracy measurement (99.26%). The system demonstrates an average time delay of 14 s in transmitting data to a doctor application via Wi-Fi compared with an average time of 68 s via a 3G mobile network. The proposed system achieves low power consumption against time (4 h 21 m 30 s) and the main and auxiliary requirements for remotely monitoring multiple parameters simultaneously with secure data. Conclusions. The proposed system can offer economic benefits for remotely monitoring patients living alone or in rural areas, thereby improving medical services, if manufactured in large quantities.

2021 ◽  
Author(s):  
Jincheng Lu ◽  
Zixuan Ou ◽  
Ziyu Liu ◽  
Cheng Han ◽  
Wenbin Ye

2013 ◽  
Vol 753-755 ◽  
pp. 2369-2373
Author(s):  
Yu Xuan Hu ◽  
Yi Hu ◽  
Shu Ming Ye ◽  
Xiao Xiang Zheng

As a major indicator of Obstructive Sleep Apnea Syndrome (OSAS) in clinical diagnosis, the monitoring of sleep apnea plays an important role in medical treatments of modern society. This paper proposes a portable sleep apnea monitoring system, which is of high-precision and low-power consumption, and capable of performing the long-term monitoring of OSAS patients multiple physiological parameters in clinical treatments. In the system, the AC modulated detection is adopted, and low amplification ratios are utilized in forestage and a high-resolution AD converter is designed in post-stages. Thus, it is able to acquire, analyze, and process physiological signals in real-time. In addition, ultralow-power chips are used in control system to save the power consumption. The experimental results show that our monitoring system has the strengths of high stability, low-power consumption (peak current90mA), and strong anti-interference ability, which demonstrates the potential in practical applications.


2012 ◽  
Vol 38 (1) ◽  
pp. 14-18
Author(s):  
黄战华 HUANG Zhanhua ◽  
杨鹤猛 YANG Hemeng ◽  
孙立彬 SUN Libin ◽  
蔡怀宇 CAI Huaiyu

2019 ◽  
Vol 8 (2) ◽  
pp. 32 ◽  
Author(s):  
Ali Al-Naji ◽  
Ali J. Al-Askery ◽  
Sadik Kamel Gharghan ◽  
Javaan Chahl

Continuous monitoring of breathing activity plays a major role in detecting and classifying a breathing abnormality. This work aims to facilitate detection of abnormal breathing syndromes, including tachypnea, bradypnea, central apnea, and irregular breathing by tracking of thorax movement resulting from respiratory rhythms based on ultrasonic radar detection. This paper proposes a non-contact, non-invasive, low cost, low power consumption, portable, and precise system for simultaneous monitoring of normal and abnormal breathing activity in real-time using an ultrasonic PING sensor and microcontroller PIC18F452. Moreover, the obtained abnormal breathing syndrome is reported to the concerned physician’s mobile telephone through a global system for mobile communication (GSM) modem to handle the case depending on the patient’s emergency condition. In addition, the power consumption of the proposed monitoring system is reduced via a duty cycle using an energy-efficient sleep/wake scheme. Experiments were conducted on 12 participants without any physical contact at different distances of 0.5, 1, 2, and 3 m and the breathing rates measured with the proposed system were then compared with those measured by a piezo respiratory belt transducer. The experimental results illustrate the feasibility of the proposed system to extract breathing rate and detect the related abnormal breathing syndromes with a high degree of agreement, strong correlation coefficient, and low error ratio. The results also showed that the total current consumption of the proposed monitoring system based on the sleep/wake scheme was 6.936 mA compared to 321.75 mA when the traditional operation was used instead. Consequently, this led to a 97.8% of power savings and extended the battery life time from 8 h to approximately 370 h. The proposed monitoring system could be used in both clinical and home settings.


2014 ◽  
Vol 699 ◽  
pp. 816-821
Author(s):  
Mohamad Riduwan Md Nawawi ◽  
Johar Akbar Mohamat Gani ◽  
Mohd Ruzaini Hashim ◽  
Mohanraj Letchimenan ◽  
Sundram Ramahlingam

Utility monitoring system plays a vital role for consumers in domestic areas to identify their electric power usage, thus creates awareness, motivates and educates consumers about saving power consumption. This paper develops a monitoring system for electric power usage, designed consisting of a digital meter, display unit, microcontroller, auto-generated data-based logging and communication device. The system is in real-time structure which measures the power usage by hourly basis and displays the results in kWh every time in convenient and organized manner. The data-based logging feature enables utility usage information to be recorded in timely basis. An additional feature provided in this system is a notification module that send charges information corresponding to consumer’s utility usage. Consumers are able to be aware of the utility usage with the corresponding charges at real-time basis as well as capable to predict, control and manage their utility usage on daily manner. Eventually this system is beneficial for both parties which are the consumers and the utility provider.


Sign in / Sign up

Export Citation Format

Share Document