scholarly journals Multiphase Flow Coupling Behavior of Bubbles Based on Computational Fluid Dynamics during AFP Process: The Behavior Characteristics of Bubbles during AFP Process

2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Jinglan Guo ◽  
Siyuan Wang

To investigate the mechanism of the effect of process parameters on bubble flow behavior during automated fiber placement (AFP) and the relationship between the bubble and voids, mechanical properties of laminates, this paper analyzes the multiphase flow coupling behavior of the bubble and fiber formation using computational fluid dynamics (CFD) and finite element (FE) method under different AFP process parameters. The effects of AFP process parameters on bubble characteristics and fiber deformation are then discussed, respectively, including bubble displacement, maximum cross-sectional area, the lowest internal temperature of the bubble, bubble breakup, and maximum deformation of the fiber. Furthermore, the AFP and corresponding test experiments are performed to investigate the relationships between different bubble characteristics and void content, mechanical properties, mainly interlaminar shear strength (ILSS) and flexural strength (FS). The results show that the maximum cross-sectional area of bubbles is closely related to the AFP process parameters. The FS and ILSS are positively correlated with the maximum cross-sectional area. With the increase of bubble displacement and fiber maximum deformation, FS and ILSS are first increased and then decreased.

2010 ◽  
Vol 638-642 ◽  
pp. 675-680 ◽  
Author(s):  
Martina Thomann ◽  
Nina von der Höh ◽  
Dirk Bormann ◽  
Dina Rittershaus ◽  
C. Krause ◽  
...  

Current research focuses on magnesium based alloys in the course of searching a resorbable osteosynthetic material which provides sufficient mechanical properties besides a good biocompatibility. Previous studies reported on a favorable biocompatibility of the alloys LAE442 and MgCa0.8. The present study compared the degradation process of cylindrical LAE442 and MgCa0.8 implants after 12 months implantation duration. Therefore, 10 extruded implants (2.5 x 25 mm, cross sectional area 4.9 mm²) of both alloys were implanted into the medullary cavity of both tibiae of rabbits for 12 months. After euthanization, the right bone-implant-compound was scanned in a µ-computed tomograph (µCT80, ScancoMedical) and nine uniformly distributed cross-sections of each implant were used to determine the residual implants´ cross sectional area (Software AxioVisionRelease 4.5, Zeiss). Left implants were taken out of the bone carefully. After weighing, a three-point bending test was carried out. LAE442 implants degraded obviously slower and more homogeneously than MgCa0.8. The mean residual cross sectional area of LAE442 implants was 4.7 ± 0.07 mm². MgCa0.8 showed an area of only 2.18 ± 1.03 mm². In contrast, the loss in volume of LAE442 pins was more obvious. They lost 64 % of their initial weight. The volume of MgCa0.8 reduced clearly to 54.4 % which corresponds to the cross sectional area results. Three point bending tests revealed that LAE442 showed a loss in strength of 71.2 % while MgCa0.8 lost 85.6 % of its initial strength. All results indicated that LAE442 implants degraded slowly, probably due to the formation of a very obvious degradation layer. Degradation of MgCa0.8 implants was far advanced.


2008 ◽  
Vol 105 (3) ◽  
pp. 805-810 ◽  
Author(s):  
C. Couppé ◽  
M. Kongsgaard ◽  
P. Aagaard ◽  
P. Hansen ◽  
J. Bojsen-Moller ◽  
...  

The purpose of this study was to examine patellar tendon (PT) size and mechanical properties in subjects with a side-to-side strength difference of ≥15% due to sport-induced loading. Seven elite fencers and badminton players were included. Cross-sectional area (CSA) of the PT obtained from MRI and ultrasonography-based measurement of tibial and patellar movement together with PT force during isometric contractions were used to estimate mechanical properties of the PT bilaterally. We found that distal tendon and PT, but not mid-tendon, CSA were greater on the lead extremity compared with the nonlead extremity (distal: 139 ± 11 vs. 116 ± 7 mm2; mid-tendon: 85 ± 5 vs. 77 ± 3 mm2; proximal: 106 ± 7 vs. 83 ± 4 mm2; P < 0.05). Distal tendon CSA was greater than proximal and mid-tendon CSA on both the lead and nonlead extremity ( P < 0.05). For a given common force, stress was lower on the lead extremity (52.9 ± 4.8 MPa) compared with the nonlead extremity (66.0 ± 8.0 MPa; P < 0.05). PT stiffness was also higher in the lead extremity (4,766 ± 716 N/mm) compared with the nonlead extremity (3,494 ± 446 N/mm) ( P < 0.05), whereas the modulus did not differ (lead 2.27 ± 0.27 GPa vs. nonlead 2.16 ± 0.28 GPa) at a common force. These data show that a habitual loading is associated with a significant increase in PT size and mechanical properties.


Author(s):  
Xini Zhang ◽  
Liqin Deng ◽  
Songlin Xiao ◽  
Lu Li ◽  
Weijie Fu

Background: Patients with Achilles tendon (AT) injuries are often engaged in sedentary work because of decreasing tendon vascularisation. Furthermore, men are more likely to be exposed to AT tendinosis or ruptures. These conditions are related to the morphological and mechanical properties of AT, but the mechanism remains unclear. This study aimed to investigate the effects of sex on the morphological and mechanical properties of the AT in inactive individuals. Methods: In total, 30 inactive healthy participants (15 male participants and 15 female participants) were recruited. The AT morphological properties (cross-sectional area, thickness, and length) were captured by using an ultrasound device. The AT force–elongation characteristics were determined during isometric plantarflexion with the ultrasonic videos. The AT stiffness was determined at 50%–100% maximum voluntary contraction force. The AT strain, stress, and hysteresis were calculated. Results: Male participants had 15% longer AT length, 31% larger AT cross-sectional area and 21% thicker AT than female participants (p < 0.05). The plantarflexion torque, peak AT force, peak AT stress, and AT stiffness were significantly greater in male participants than in female participants (p < 0.05). However, no significant sex-specific differences were observed in peak AT strain and hysteresis (p > 0.05). Conclusions: In physically inactive adults, the morphological properties of AT were superior in men but were exposed to higher stress conditions. Moreover, no significant sex-specific differences were observed in peak AT strain and hysteresis, indicating that the AT of males did not store and return elastic energy more efficiently than that of females. Thus, the mechanical properties of the AT should be maintained and/or improved through physical exercise.


2021 ◽  
Author(s):  
Hui Cao ◽  
Wenke Chen ◽  
Zhiyuan Rui ◽  
Changfeng Yan

Abstract Metal nanomaterials exhibit excellent mechanical properties compared with corresponding bulk materials and have potential applications in various areas. Despite a number of studies of the size effect on Cu nanowires mechanical properties with square cross-sectional, investigations of them in rectangular cross-sectional with various sizes at constant volume are rare, and lack of multifactor coupling effect on mechanical properties and quantitative investigation. In this work, the dependence of mechanical properties and deformation mechanisms of Cu nanowires/nanoplates under tension on cross-sessional area, aspect ratio of cross-sectional coupled with orientation were investigated using molecular dynamics simulations and the semi-empirical expressions related to mechanical properties were proposed. The simulation results show that the Young’s modulus and the yield stress sharply increase with the aspect ratio except for the <110>{110}{001} Cu nanowires/nanoplates at the same cross-sectional area. And the Young’s modulus increases while the yield stress decreases with the cross-sectional area of Cu nanowires. However, both of them increase with the cross-sectional area of Cu nanoplates. Besides, the Young’s modulus increases with the cross-sectional area at all the orientations. The yield stress shows a mildly downward trend except for the <111> Cu nanowires with increased cross-sectional area. For the Cu nanowires with a small cross-sectional area, the surface force increases with the aspect ratio. In contrast, it decreases with the aspect ratio increase at a large cross-sectional area. At the cross-sectional area of 13.068 nm2, the surface force decreases with the aspect ratio of the <110> Cu nanowires while it increases at other orientations. The surface force is a linearly decreasing function of the cross-sectional area at different orientations. Quantitative studies show that Young’s modulus and yield stress to the aspect ratio of the Cu nanowires satisfy exponent relationship. In addition, the main deformation mechanism of Cu nanowires is the nucleation and propagation of partial dislocations while it is the twinning-dominated reorientation for Cu nanoplates.


2019 ◽  
Vol 4 (4) ◽  
pp. 2473011419S0045
Author(s):  
Jennifer A. Zellers ◽  
Jeremy Eekhoff ◽  
Remy Walk ◽  
Simon Y. Tang ◽  
Mary K. Hastings ◽  
...  

Category: Diabetes Introduction/Purpose: Advanced glycation endproducts (AGEs) accumulate in tendon tissue in individuals with diabetes mellitus (DM). Although AGEs have been shown to impact tendon function by decreasing collagen sliding, this relationship has not been explored in humans with diabetes. Despite the prevalence of foot deformity in this population and implications of posterior tibialis dysfunction, the mechanical behavior of the posterior tibialis tendon has only been reported in a small (n=5), cadaveric study that did not report DM status. Therefore, the purpose of this study is to determine the effects of DM-associated AGEs accumulation on the mechanical properties of the posterior tibialis tendon. Methods: Posterior tibialis tendons were collected from individuals with and without DM undergoing lower extremity amputation. A 1-2 mm tendon transection was used for AGEs quantification. AGEs were quantified via fluorescence following papain digestion and hydrolyzation as described previously. Fluorescence was compared to a quinine standard to calculate AGEs content, which was normalized to sample wet weight. Tensile mechanical testing was completed with the remaining specimen (˜25 mm long). Tendon cross-sectional area was measured with a non-contact laser scanning device. Specimens were preloaded to 10 N and preconditioned for 10 cycles at 6% strain, subjected to stress-relaxation at 6% strain for 10 minutes, and loaded with a triangular waveform to a maximum of 10% strain at a rate of 1% strain per second. Individual values and group descriptive statistics are reported for AGEs content and mechanical testing. Relationships between AGEs content and various mechanical testing parameters were evaluated using Spearman correlation. Results: Six individuals (5 with DM, 4 male, mean(SD) age: 56(5)years) were included. AGEs content was increased in DM tendon (DM: 20.5(5.1), non-DM: 9.5 ng quinine/mg wet weight). Compared to non-DM tendon, DM tendons had larger cross-sectional area (DM: 44.3(4.9), non-DM: 11mm2). From stress relaxation, DM tendons had smaller peak (DM: 0.41(0.25), non-DM: 1.16 MPa) and equilibrium stress (DM: 0.23(0.13), non-DM: 0.83 MPa), and larger percent relaxation (DM: 46(6)%, non-DM: 29%)(Figure 1-A). DM tendons had decreased maximum stress at 10% strain (DM: 0.63(0.45), non-DM: 1.75 MPa), increased linear stiffness (DM: 35.2(27.6), non-DM: 19.2N/mm), and decreased linear modulus (DM: 8.5(7.0), non-DM: 20.1 MPa)(Figure 1-B, C) compared to non- DM tendon. Hysteresis (i.e., energy loss upon unloading) was higher in DM tendons (DM: 0.35(0.05), non-DM: 0.22), and positively correlated to AGEs (rho=0.943, p=0.005, Figure 1-D). Conclusion: Posterior tibialis tendons with DM exhibited increased AGEs content and altered mechanical properties. DM tendons were less stiff when accounting for cross-sectional area but had 2-4x the cross-sectional area of non-DM tendon, with inconsistent patterns in total tendon stiffness potentially attributable to several factors. DM tendons showed impaired energy storage and return, which was most strongly associated with AGEs. Non-DM samples were limited and the linear modulus was smaller than previously reported, however, all but one DM tendon had a modulus less than 50% of the non-DM sample. Future work will explore the mechanisms of AGEs-associated DM tendon impairments.


Author(s):  
Szu Yung Chen ◽  
Lu Zhang ◽  
Yumiko Sekino ◽  
Hiroyoshi Watanabe

Abstract The following study describes the optimization design procedure of a double-suction pump. BASELINE pump is designed as inlet nozzle diameter 800 mm and impeller outlet diameter 740 mm. Each component of a BASELINE pump, impeller configurations, discharge volute, and the suction casing were determined by DOE (Design of Experiments) and sensitivity analysis. However, finite selected design parameters for each component are mostly restricted to the free surface design of the pump casing. In this study, the optimization method approach along with steady Computational Fluid Dynamics (CFD) is introduced to achieve the high efficiency request of a double-suction pump. To investigate the matching optimization of the impeller and discharge volute at design point, the full parametric geometry of discharge volute was developed referred to the BASELINE shape and Multi-Objective Genetic Algorithm NSGA-II (Non-dominated Sorting Genetic Algorithm II) was used. Optimization result shows that by increasing the volute cross-sectional area from the volute tongue till the circumferential angle 180 deg. provides lower loss. This is due to the improvement achieved for the better distribution of the velocity gradient within the volute. A validated unsteady computational fluid dynamics (CFD) was also employed to investigate the performance difference between optimized volute design and the BASELINE which correlated to the pressure fluctuation and secondary flow behavior inside the cross-sections from 80% to 120% of nominal flow rate. The result shows that the flow distortion in the streamwise direction is stronger with the BASELINE and sensitively affects the operation stability. This is due to the different secondary flow pattern in the cross-sections, hence demonstrating a design direction of desired volute cross-sectional shape for high-performance can be used in a double-suction volute pump.


2020 ◽  
Vol 6 (12) ◽  
pp. 2375-2396
Author(s):  
Cecielle N. Dacuan ◽  
Virgilio Abellana ◽  
Hana Astrid Canseco

Corrosion is one of the significant deteriorations of reinforced concrete structures. It accelerated the performance loss of the structures, leading to a cross-sectional reduction of steel, which affects its mechanical properties, particularly its tensile capacity and ductility. The purpose of this study is to assess the serviceability and safety of corroded-damaged structures, particularly those exposed to aggressive marine environments. A total of 54 pcs of 150 mm-diameter and 300mm-height of cylindrical specimen were cast. Small-scaled specimens were accelerated to corrosion using impressed current techniques with a constant current density of 200 µA/cm2. Samples were immersed in a simulated environment with a 5% solution of sodium bicarbonate during corrosion acceleration. Corrosion alters the surface configuration of the steel bar. Pitting corrosions due to chloride aggression causes the residual cross-sectional area of corroded rebars to no longer round and varies considerably along its circumference and length. The reduction of the steel cross-sectional area has a significant impact on the degradation of the strength and durability of reinforcing structures. The residual capacity of the corroded reinforcement decreases with the reduction of the cross-sectional area of the steel reinforcement. The rate of corrosion affects the extent of the remaining service life of a corroded reinforced concrete structure. Doi: 10.28991/cej-2020-03091624 Full Text: PDF


2021 ◽  
Vol 143 (6) ◽  
Author(s):  
Sophia K. Theodossiou ◽  
Nicholas M. Pancheri ◽  
Alleyna C. Martes ◽  
Aimee L. Bozeman ◽  
Michele R. Brumley ◽  
...  

Abstract Mechanical loading may be required for proper tendon formation. However, it is not well understood how tendon formation is impacted by the development of weight-bearing locomotor activity in the neonate. This study assessed tendon mechanical properties, and concomitant changes in weight-bearing locomotion, in neonatal rats subjected to a low thoracic spinal cord transection or a sham surgery at postnatal day (P)1. On P10, spontaneous locomotion was evaluated in spinal cord transected and sham controls to determine impacts on weight-bearing hindlimb movement. The mechanical properties of P10 Achilles tendons (ATs), as representative energy-storing, weight-bearing tendons, and tail tendons (TTs), as representative positional, non-weight-bearing tendons were evaluated. Non- and partial weight-bearing hindlimb activity decreased in spinal cord transected rats compared to sham controls. No spinal cord transected rats showed full weight-bearing locomotion. ATs from spinal cord transected rats had increased elastic modulus, while cross-sectional area trended lower compared to sham rats. TTs from spinal cord transected rats had higher stiffness and cross-sectional area. Collagen structure of ATs and TTs did not appear impacted by surgery condition, and no significant differences were detected in the collagen crimp pattern. Our findings suggest that mechanical loading from weight-bearing locomotor activity during development regulates neonatal AT lateral expansion and maintains tendon compliance, and that TTs may be differentially regulated. The onset and gradual increase of weight-bearing movement in the neonate may provide the mechanical loading needed to direct functional postnatal tendon formation.


2021 ◽  
pp. 540-546
Author(s):  
K.V. Malyutin ◽  
V.V. Ovchinnikov

The results of the study of the influence of the main parameters of laser powder surfacing of steel 08Х14Н5М2ДЛ on the dimensions of the applied rollers are presented. The parameters of the applied rollers were the width of the roller, the height of the roller, the depth of penetration of the substrate, the value of the zone of thermal influence, the angle of wetting of the roller, the cross-sectional area of the coating and the cross-sectional area of the molten part of the substrate. Rational values of process parameters are determined, which provide minimal penetration of the substrate during the formation of the height of the deposited roller at the level of 3.2...3.5 mm. Analysis of the welded rollers showed the absence of defects both in themselves and in the substrate material.


Sign in / Sign up

Export Citation Format

Share Document