scholarly journals Diagnosis and Fault-Tolerant Control of Six-Phase Wind Turbine under Multiple Open-Switch Faults

2021 ◽  
Vol 2021 ◽  
pp. 1-16
Author(s):  
Rouhollah Bolbolnia ◽  
Karim Abbaszadeh ◽  
Mojtaba Nasiri

A new open-switch fault diagnosis method is proposed in this paper for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The single and multiple open-switch faults are detected without any additional equipment and complicated calculations since the proposed fault detection method is integrated with the hysteresis controller. The proposed fault-tolerant technique reduces the value of overcurrent and total harmonic distortion on the side phases of the faulty one, by changing the switching signal of one switch in its opposite phase in some regions. This technique is performed without adding any legs, switches, or triode for alternating currents to the circuit. Finally, the proposed fault-tolerant technique is evaluated by MATLAB simulation and the results show its effectiveness.

2015 ◽  
Vol 764-765 ◽  
pp. 740-746
Author(s):  
Hang Yuan ◽  
Chen Lu ◽  
Ze Tao Xiong ◽  
Hong Mei Liu

Fault detection for aileron actuators mainly involves the enhancement of reliability and fault tolerant capability. Considering the complexity of the working conditions of aileron actuators, a fault detection method for an aileron actuator under variable conditions is proposed in this study. A bi-step neural network is utilized for fault detection. The first neural network, which is employed as the observer, is established to monitor the aileron actuator and generate the residual error. The other neural network generates the corresponding adaptive threshold synchronously. Faults are detected by comparing the residual error and the threshold. In considering of the variable conditions, aerodynamic loads are introduced to the bi-step neural network. The training order spectrums are designed. Finally, the effectiveness of the proposed scheme is demonstrated by a simulation model with different faults.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2571 ◽  
Author(s):  
Tan Yanghong ◽  
Zhang Haixia ◽  
Zhou Ye

The conversion system is a major contributor to failure rates. These faults lead to time and cost consuming. Fault diagnosis capabilities pay as a solver to achieve a steady system. This paper presents a full analysis of permanent magnet synchronous generator wind system (PMSGWS) and proposes a special RMS voltage-based fault diagnosis method. The full analysis presents a comprehensive knowledge of faulty behaviors especially under arm current flowing or cutting off. Due to enough knowledge of faulty behaviors, the implementation of the detection method without threshold setting is contributed by the special RMS voltage. Its sample period is set longer than the time of the maximum pulse width ratio (MPR) and shorter than the fault show time of lower tube voltage. Due to this, the detection speed and robustness are achieved. By these simple settings for the fault diagnosis method, the faulty switch is detected in less than 1/4 of the period. Simulation and experimental results confirm the validity and feasibility of the new proposed fault detection method.


Author(s):  
Bilal Boudjellal ◽  
Tarak Benslimane

This paper presents the study of an open switch fault tolerant control of a grid-connected photovoltaic system. The studied system is based on the classical DC–DC boost converter and a bidirectional 6-pulse DC–AC converter. The objective is to provide an open-switch fault detection method and fault-tolerant control for both of boost converter and grid-side converter (GSC) in a grid-connected photovoltaic system. A fast fault detection method and a reliable fault-tolerant topology are required to ensure continuity of service, and achieve a faster corrective maintenance. In this work, the mean value of the error voltages is used as fault indicator for the GSC, while, for the boost converter the inductor current form is used as fault indicator. The fault-tolerant topology was achieved by adding one redundant switch to the boost converter, and by adding one redundant leg to the GSC. The results of the fault tolerant control are presented and discussed to validate the proposed approach under different scenarios and different solar irradiances.


Author(s):  
Florent Becker ◽  
Ehsan Jamshidpour ◽  
Philippe Poure ◽  
Shahrokh Saadate

In this paper, an open-switch fault diagnosis method for five-level H-Bridge Neutral Point Piloted (HB-NPP) or T-type converters is proposed. While fault tolerant operation is based on three steps (fault detection, fault localization and system reconfiguration), a fast fault diagnosis, including both fault detection and localization, is mandatory to make a suitable response to an open-circuit fault in one of the switches of the converter. Furthermore, fault diagnosis is necessary in embedded and safety critical applications, to prevent further damage and perform continuity of service.In this paper, we present an open-switch fault diagnosis method, based on the switches control orders and the observation of the converter output voltage level. In five-level converters such as HB-NPP and T-type topologies, some switches are mostly 'on' at the same time. Therefore, the fault localization is quite complicated. The fault diagnosis method we proposed is capable to detect and localize an open-switch fault in all cases. Computer simulations are carried out by using Matlab Simulink and SimPowerSystem toolbox to validate the proposed approach.


Energies ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2495 ◽  
Author(s):  
Jun-Hyung Jung ◽  
Hyun-Keun Ku ◽  
Yung-Deug Son ◽  
Jang-Mok Kim

This paper proposes a fault diagnosis and tolerant control methods for an open-switch fault caused in a three-phase three-level neutral-point-clamped (NPC) pulse-width modulation (PWM) active rectifier. The open-switch fault in the three-level NPC active rectifier causes a distortion in the input phase current and a ripple in the DC-link capacitor voltage. Therefore, proper fault diagnosis and tolerant control methods are required to prevent additional failures and performance degradation in the rectifier system. This paper conducted a detailed analysis of the effect of the single open-switch fault on the NPC PWM active rectifier and proposed a fault diagnosis method utilizing the DC link voltage and the phase angle of the input grid voltage. Furthermore, this paper proposes a fault-tolerant control method to reduce the effect of the open-switch fault by compensating a distorted reference voltage. The effectiveness of the proposed fault diagnosis and tolerant control methods are verified through experimental results.


2021 ◽  
Vol 11 (10) ◽  
pp. 4589
Author(s):  
Ivan Duvnjak ◽  
Domagoj Damjanović ◽  
Marko Bartolac ◽  
Ana Skender

The main principle of vibration-based damage detection in structures is to interpret the changes in dynamic properties of the structure as indicators of damage. In this study, the mode shape damage index (MSDI) method was used to identify discrete damages in plate-like structures. This damage index is based on the difference between modified modal displacements in the undamaged and damaged state of the structure. In order to assess the advantages and limitations of the proposed algorithm, we performed experimental modal analysis on a reinforced concrete (RC) plate under 10 different damage cases. The MSDI values were calculated through considering single and/or multiple damage locations, different levels of damage, and boundary conditions. The experimental results confirmed that the MSDI method can be used to detect the existence of damage, identify single and/or multiple damage locations, and estimate damage severity in the case of single discrete damage.


2021 ◽  
pp. 147592172199847
Author(s):  
William Soo Lon Wah ◽  
Yining Xia

Damage detection methods developed in the literature are affected by the presence of outlier measurements. These measurements can prevent small levels of damage to be detected. Therefore, a method to eliminate the effects of outlier measurements is proposed in this article. The method uses the difference in fits to examine how deleting an observation affects the predicted value of a model. This allows the observations that have a large influence on the model created, to be identified. These observations are the outlier measurements and they are eliminated from the database before the application of damage detection methods. Eliminating the outliers before the application of damage detection methods allows the normal procedures to detect damage, to be implemented. A multiple-regression-based damage detection method, which uses the natural frequencies as both the independent and dependent variables, is also developed in this article. A beam structure model and an experimental wooden bridge structure are analysed using the multiple-regression-based damage detection method with and without the application of the method proposed to eliminate the effects of outliers. The results obtained demonstrate that smaller levels of damage can be detected when the effects of outlier measurements are eliminated using the method proposed in this article.


Sign in / Sign up

Export Citation Format

Share Document