scholarly journals Developing a grid-connected DFIG strategy for the integration of wind power with harmonic current mitigation

Author(s):  
Hacil Mahieddine ◽  
Laid Zarour ◽  
Louze Lamri ◽  
Nemmour Ahmed Lokmane

<p>The aim of this paper is to present a study of the efficiency of the electrical part of a wind generation system. Two back-to-back PWM voltage-fed inverters connected between the stator and the rotor are used to allow bidirectional power flow. The second inverter grid side, has a role of a power active filter, to eliminate the harmonic generated by the non linear load, in the same time gives an active and reactive power needed by the rotor of DFIG. The harmonics of switching frequency in the current stator, pose a major problem in the moment where commutations in the diode bridge, to solve this problem, we introduce a small-sized passive LC filter for the purpose of eliminating high-frequency shaft voltage and grid current from a DFIG driven by a voltage-source pulse width-modulation rotor inverter controlled with SVM. The control theory is discussed, and the controller implementation is described. Design criteria are also given. The results of simulation tests show excellent static and dynamic performances.</p>

2013 ◽  
Vol 448-453 ◽  
pp. 1988-1993
Author(s):  
Ji Zhong Wang ◽  
Chao Nan Tong ◽  
Rui Li

Based on the synchronous machine in AC-DC-AC Frequency speed drag System, a new power supply method of phase shifting combination is proposed by a detailed study of the impact in the power grid harmonics. With regard to the main Motor drive system of hot-rolling finishing mills, a large number of varying parameters quantitative analysis is made respectively for power load, LC filter, pulse-width modulation circuit and transformer, in which the grid side harmonic rate and waveform distortion rate is focused on. The simulation results show that the power supply method with reasonable parameters design of the drag system can be drastically reduce the grid side harmonic interference that the total harmonic distortion is suppressed within 4.0%. Results of this study provides an effective method for the design of the factory drag system, reactive power compensation system as well as fault diagnosis of electric drag system.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Chia-Nan Wang ◽  
Wen-Chang Lin ◽  
Xuan-Khoa Le

The aim of this research is to model an autonomous control wind turbine driven permanent magnetic synchronous generator (PMSG) which feeds alternating current (AC) power to the utility grid. Furthermore, this research also demonstrates the effects and the efficiency of PMSG wind turbine which is integrated by autonomous controllers. In order for well autonomous control, two voltage source inverters are used to control wind turbine connecting with the grid. The generator-side inverter is used to adjust the synchronous generator as well as separating the generator from the grid when necessary. The grid-side inverter controls the power flow between the direct current (DC) bus and the AC side. Both of them are oriented control by space vector pulse width modulation (PWM) with back-to-back frequency inverter. Moreover, the proportional-integral (PI) controller is enhanced to control both of the inverters and the pitch angle of the wind turbine. Maximum power point tracking (MPPT) is integrated in generator-side inverter to track the maximum power, when wind speed changes. The simulation results in Matlab Simulink 2012b showing the model have good dynamic and static performance. The maximum power can be tracked and the generator wind turbine can be operated with high efficiency.


2011 ◽  
Vol 55-57 ◽  
pp. 813-818
Author(s):  
Guang Guo Zhang ◽  
Wei Jiang

The rectifier implements bidirectional power flow, sinusoidal current and unit power factor control in grid side. This paper describes the design and implementation of the current inner-loop and the voltage outer-loop based on space vector pulse width modulation (SVPWM). A control system based on the fuzzy self-tuning PID for three-phase rectifier is proposed in this paper. The new algorithm based on the fuzzy self-tuning PID can improve the performance of the system. Also, the overshoot of the voltage fluctuation is reduced. Simulation and experimentation results show that the validity of the proposed strategy.


2014 ◽  
Vol 698 ◽  
pp. 150-154 ◽  
Author(s):  
A.A. Radionov ◽  
A.S. Maklakov ◽  
E.A. Karyakina

This paper addresses the issue of functional possibilities of reversible electric drive based on active front end rectifier and voltage source inverter from the point of view of energy saving. This paper will review all theoretical capabilities of reactive power compensation in the supply mains by the active front end rectifiers. The reactive power consumption or generation can be created out by using of active front end converters which connect the electric drive with supply mains. Active front end rectifiers can be actively used in operation of supply mains of enterprise as they are able to provide controlled power factor and bidirectional power flow. The studies by mathematical modeling in the Matlab/Simulink program were carried out. It was established that the controlling of power factor of active front end rectifier can be used for reactive power compensation in supply mains. The huge prospects of energy-saving reversible electric drive integration to the Smart Grid have been determined as it is able to provide high power and capabilities of the controlling reactive power flow by means of active front end rectifier. It can reduce a share of the consumption reactive power from a substation and to improve the power quality.


2015 ◽  
Vol 9 (1) ◽  
pp. 553-559
Author(s):  
HU Xin-xin ◽  
Chen Chun-lan

In order to optimize the electric energy quality of HVDC access point, a modular multilevel selective harmonic elimination pulse-width modulation (MSHE-PWM) method is proposed. On the basis of keeping the minimum action frequency of the power device, MSHE-PWM method can meet the requirement for accurately eliminating low-order harmonics in the output PWM waveform. Firstly, establish the basic mathematical model of MMC topology and point out the voltage balance control principle of single modules; then, analyze offline gaining principle and realization way of MSHEPWM switching angle; finally, verify MSHE-PWM control performance on the basis of MMC reactive power compensation experimental prototype. The experimental result shows that the proposed MSHE-PWM method can meet such performance indexes as low switching frequency and no lower-order harmonics, and has verified the feasibility and effectiveness thereof for optimizing the electric energy quality of HVDC access point.


2018 ◽  
Vol 41 (9) ◽  
pp. 2451-2464
Author(s):  
Moushumi Patowary ◽  
Gayadhar Panda ◽  
Bimal C Deka

This paper presents the collective operation and comparative assessment of artificial neural network (ANN)-based adaptive controller with detuned-inductor capacitor (LC) filter facility in grid-tied voltage source control (VSC) system. In order to facilitate proper shaping of VSC outputs and to avoid voltage surge or current surge issues that may occur during the synchronization, the controlling action should reflect importance of total impedance (Zt) effect for: (i) accurate online weight updating, (ii) generation of correct references for proper shaping of VSC outputs, (iii) accurate assessment and exclusion of current harmonics and (iv) robust in defending any system perturbation. This impedance is taken into consideration during the run-time weight updation process through extended control steps in order to pass over various losses that certainly occurs in transformers, filters, line parameters and so forth. Performance of the system is well improved with an inclusion of total impedance (Zt) measured between the VSC and point of common coupling (PCC). A detuned-LC filter is predominantly intended for reactive power compensation, power factor correction, prompt and accurate alleviation of the harmonics. A comparative assessment in between enhanced and conventional adaptive controllers that are designed in MATLAB/Simulink clarifies the robust performances of the proposed control design under sundry system turbulences. The verification of the proposed enhanced controller is approved with the hardware results obtained using dSPACE RTI 1202 kit.


2021 ◽  
Author(s):  
Venkata Narasimha Rao Yaramasu

This dissertation proposes two novel medium voltage (MV) multilevel converter configurations for use with permanent magnet synchronous generator (PMSG) based megawatt (MW) wind energy conversion systems (WECS). The classical control techniques, based on linear PI regulators and low band-width modulation, present several technical issues during lower switching frequency operation. To overcome these issues, a high performance finite control-set model predictive control (FCS-MPC) strategy is proposed to control the power converters employed in the MW-PMSG-WECS. The proposed three-level and four-level converters combine the advantages of proven wind turbine technologies, such as low-cost generator-side passive converters, and efficient gridside multilevel converters. The intermediate dc-dc multilevel converters ensure balancing of the capacitor voltages during all operating conditions. With this feature, the grid-side multilevel converters produce better grid current waveforms compared to the back-to-back connected converters. A generalized approach for the predictive control of an n-level diode-clamped converter was investigated. The FCS-MPC strategy for current control and decoupled active/reactive power regulation of grid-connected multilevel converters was also analyzed. The major WECS requirements such as maximum power point tracking, balancing of dc-link capacitor voltages, switching frequency minimization, common-mode voltage mitigation, regulation of net dc-bus voltage, and grid reactive power control have been modeled in terms of power converter switching states. These control objectives have been accomplished during each sampling interval by selecting the switching states which minimize the generator- and grid-side cost functions. Issues related to the weighting factors selection, control delay compensation, accurate extrapolation of references, control of variable switching frequency nature, prediction of variables over two samples with reduced computational burden, and robustness analysis, are also addressed in this dissertation. To keep the dc-bus voltage constant during low voltage ride-through operation, predictive control scheme is proposed for the power converters while storing surplus energy in the turbine-generator rotor inertia. The generation and exchange of reference control variables during symmetrical grid voltage dips is suggested to meet the grid code requirements. The proposed solution is efficient as no energy is dissipated in the dc-link crowbar. The simulation and experimental results validate the proposed MV converters and predictive control schemes.


Author(s):  
Maruf A. Aminu

This paper is presented in an attempt to validate the dynamic response of a microgrid to line-to-line short circuit. The microgrid components include two identical Wind Turbine Generators (WTGs) tied to a 100MVA, 13.8kV utility via a Point of Common Coupling (PCC). The utility-microgrid testbed is modeled in SIMPOWERSystems® using two Doubly-Fed Induction Generators (DFIGs) in the microgrid side. While in islanded operating mode, line-to-line short circuit fault is applied at 6.0s and withdrawn at 8.0s, obtaining a 50.0s dynamic response of the system for different fault locations, under voltage and reactive power control regimes of the wind turbine controller. For measurement purpose, the absolute value of the stator complex voltage is transformed to  reference frame. Bidirectional power flow between the two feeders is established in the study. The study also confirms that the microgrid composed of DFIGs offer reactive power management capability, particularly by presenting superior performance when stressed under Q control regime than under V control regime. Finally, the response of the testbed to line-to-line short circuit has been validated and shown to be consistent with established short circuit theory.


2013 ◽  
Vol 768 ◽  
pp. 3-8 ◽  
Author(s):  
M. Venmathi ◽  
R. Ramaprabha

This paper presents the comparative dynamic analysis of full bridge and half bridge three port dc-dc converter topology interfacing the renewable energy sources along with the energy storage devices. The three port converter comprises the active bridge circuit and the three winding transformer. It uses single power conversion stage with high frequency link to control power flow between the batteries, load and the renewable energy sources. The power flow between the ports is controlled by phase shifting the square wave outputs of the active bridges in combination with pulse width modulation (PWM) technique. The analysis reveals that the battery discharges when the source is not sufficient to supply the load and it was charged when the source alone is capable of supplying the load. Hence there is a bidirectional power flow in the storage port when there is a transition in the source.


2011 ◽  
Vol 55-57 ◽  
pp. 1361-1364
Author(s):  
Jun Li Zhang ◽  
Xiao Feng Lv ◽  
Chao Li

With the growth of industry manufacturers and population, power quality becomes more and more important issue, and is attracting significant attention due to the increase in the number of sensitive loads. A distribution static compensator (DSTATCOM) is a voltage source inverter (VS1)-based power electronic device, which is usually used to compensate reactive power and sustain the system voltage in distribution power system. Compared with the traditional STATCOM, multilevel STATCOMs exhibit faster dynamic response, smaller volume, lower cost, and higher ratings. A multilevel inverter connected to an energy storage device can control both active and reactive power flow, providing more flexible and versatile power transmission operation. SPWM is actually a kind of multi-pulse trigger mode and used to trigger the switches in DSTATCOM.


Sign in / Sign up

Export Citation Format

Share Document