Pareto Optimal Reconfiguration of Power Distribution Systems with Load Uncertainty and Recloser Placement Simultaneousely Using a Genetic Algorithm Based on NSGA-II

Author(s):  
Sina Khajeh Ahmad Attari ◽  
Mahmoud reza Shakarami ◽  
Farhad Namdari

<em><span>Reconfiguration, by exchanging the functional links between the elements of the system, represents one of the most important measures which can improve the operational performance of a distribution system. Besides, reclosers use to eliminate transient faults, faults isolation, network management and enhance reliability to reduce customer outages. For load uncertainty a new method based on probabilistic interval arithmetic approach is used to incorporate uncertainty in load demand that can forecast reasonably accurate operational conditions of radial system distribution (RDS) with better computational efficiency.<strong> </strong>In this paper, the optimization process is performed by considering power loss reduction along with reliability index as objective functions. Simulation results on radial 33 buses test system indicates that simultaneous optimization of these two issues has significant impact on system performance.</span></em>

Author(s):  
A. V. Sudhakara Reddy ◽  
M. Damodar Reddy ◽  
M. Satish Kumar Reddy

This manuscript presents a feeder reconfiguration in primary distribution networks with an objective of minimizing the real power loss or maximization of power loss reduction. An optimal switching for the network reconfiguration problem is introduced in this article based on step by step switching and simultaneous switching. This paper proposes a Grey Wolf Optimization (GWO) algorithm to solve the feeder reconfiguration problem through fitness function corresponding to optimum combination of switches in power distribution systems. The objective function is formulated to solve the reconfiguration problem which includes minimization of real power loss. A nature inspired Grey Wolf Optimization Algorithm is utilized to restructure the power distribution system and identify the optimal switches corresponding minimum power loss in the distribution network. The GWO technique has tested on standard IEEE 33-bus and 69-bus systems and the results are presented.


2019 ◽  
Vol 22 (3) ◽  
Author(s):  
Ivo Benitez Cattani

In this paper two reconfiguration methodologies for three-phase electric power distribution systems based on multi-objective optimization algorithms are developed in order to simultaneously optimize two objective functions, (1) power losses and (2) three-phase unbalanced voltage minimization. The proposed optimization involves only radial topology configurations which is the most common configuration in electric distribution systems. The formulation of the problem considers the radiality as a constraint, increasing the computational complexity. The Prim and Kruskal algorithms are tested to fix infeasible configurations. In distribution systems, the three-phase unbalanced voltage and power losses limit the power supply to the loads and may even cause overheating in distribution lines, transformers and other equipment. An alternative to solve this problem is through a reconfiguration process, by opening and/or closing switches altering the distribution system configuration under operation. Hence, in this work the three-phase unbalanced voltage and power losses in radial distribution systems are addressed as a multi-objective optimization problem, firstly, using a method based on weighted sum; and, secondly, implementing NSGA-II algorithm. An example of distribution system is presented to prove the effectiveness of the proposed method.


Author(s):  
Ahmed Mohamed Abdelbaset ◽  
AboulFotouh A. Mohamed ◽  
Essam Abou El-Zahab ◽  
M. A. Moustafa Hassan

<p><span>With the widespread of using distributed generation, the connection of DGs in the distribution system causes miscoordination between protective devices. This paper introduces the problems associated with recloser fuse miscoordination (RFM) in the presence of single and multiple DG in a radial distribution system. Two Multi objective optimization problems are presented. The first is based on technical impacts to determine the optimal size and location of DG considering system power loss reduction and enhancement the voltage profile with a certain constraints and the second is used for minimizing the operating time of all fuses and recloser with obtaining the optimum settings of fuse recloser coordination characteristics. Whale Optimizer algorithm (WOA) emulated RFM as an optimization problem. The performance of the proposed methodology is applied to the standard IEEE 33 node test system. The results show the robustness of the proposed algorithm for solving the RFM problem with achieving system power loss reduction and voltage profile enhancement.</span></p>


Algorithms ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 14
Author(s):  
İsmail Alperen Özlü ◽  
Olzhas Baimakhanov ◽  
Almaz Saukhimov ◽  
Oğuzhan Ceylan

This paper proposes a toolbox for simulating the effective integration of renewable energy sources into distribution systems. The toolbox uses four heuristic methods: the particle swarm optimization (PSO) method, and three recently developed methods, namely Gray Wolf Optimization (GWO), Ant Lion Optimization (ALO), and Whale Optimization Algorithm (WOA), for the efficient operation of power distribution systems. The toolbox consists of two main functionalities. The first one allows the user to select the test system to be solved (33-, 69-, or 141-bus test systems), the locations of the distributed generators (DGs), and the voltage regulators. In addition, the user selects the daily active power output profiles of the DGs, and the tool solves the voltage deviation problem for the specified time of day. The second functionality involves the simulation of energy storage systems and provides the optimal daily power output of the resources. With this program, a graphical user interface (GUI) allows users to select the test system, the optimization method to be used, the number of DGs and locations, the locations and number of battery energy storage systems (BESSs), and the tap changer locations. With the simple user interface, the user can manage the distribution system simulation and see the results by making appropriate changes to the test systems.


Author(s):  
Gunjan Varshney ◽  
Durg S. Chauhan ◽  
Madhukar P. Dave ◽  
Nitin

Background: In modern electrical power distribution systems, Power Quality has become an important concern due to the escalating use of automatic, microprocessor and microcontroller based end user applications. Methods: In this paper, power quality improvement has done using Photovoltaic based Distribution Static Compensator (PV-DSTATCOM). Complete simulation modelling and control of Photovoltaic based Distribution Static Compensator have been provided in the presented paper. In this configuration, DSTATCOM is fed by solar photovoltaic array and PV module is also helpful to maintain the DC link voltage. The switching of PV-STATCOM is controlled by Unit template based control theory. Results: The performance of PV-DSTATCOM has been evaluated for Unity Power Factor (UPF) and AC Voltage Control (ACVC) modes. Here, for studying the power quality issues three-phase distribution system is considered and results have been verified through simulation based on MATLAB software. Conclusion: Different power quality issues and their improvement are studied and presented here for harmonic reduction, DC voltage regulation and power factor correction.


Mathematics ◽  
2018 ◽  
Vol 6 (9) ◽  
pp. 158
Author(s):  
Farzaneh Pourahmadi ◽  
Payman Dehghanian

Allocation of the power losses to distributed generators and consumers has been a challenging concern for decades in restructured power systems. This paper proposes a promising approach for loss allocation in power distribution systems based on a cooperative concept of game-theory, named Shapley Value allocation. The proposed solution is a generic approach, applicable to both radial and meshed distribution systems as well as those with high penetration of renewables and DG units. With several different methods for distribution system loss allocation, the suggested method has been shown to be a straight-forward and efficient criterion for performance comparisons. The suggested loss allocation approach is numerically investigated, the results of which are presented for two distribution systems and its performance is compared with those obtained by other methodologies.


Author(s):  
Wen Fan ◽  
Yuan Liao ◽  
Ning kang

AbstractAccurate fault location in distribution systems greatly shortens maintenance time and improves reliability. This paper presents novel methods to pinpoint fault location and identify possible bad measurements for enhanced accuracy. It is assumed that network parameters and topology of the distribution network are available. The methods are applicable to a single fault as well as simultaneous faults and are applicable to both balanced and unbalanced networks. The methods utilize synchronized voltage and current phasor measurements to locate the fault. The methods are validated by simulation studies using the modified IEEE 34-Node Test System. Case studies have demonstrated that the methods are suitable for distribution systems with high penetration of distributed generations.


2017 ◽  
Vol 2017 ◽  
pp. 1-16 ◽  
Author(s):  
Beibei Wang ◽  
Xiaoqing Hu ◽  
Peifeng Shen ◽  
Wenlu Ji ◽  
Yang Cao ◽  
...  

There are many uncertain factors in the modern distribution network, including the access of renewable energy sources and the heavy load level. The existence of these factors has brought challenges to the stability of the power distribution network, as well as increasing the risk of exceeding transmission capacity of distribution lines. The appearance of flexible load control technology provides a new idea to solve the above problems. Air conditioners (ACs) account for a great proportion of all loads. In this paper, the model of dispatching AC loads in the regional power grid is constructed, and the direct load control (DLC) method is adopted to reduce the load of ACs. An improved tabu search technique is proposed to solve the problem of network dispatch in distribution systems in order to reduce the resistive line losses and to eliminate the transmission congestion in lines under normal operating conditions. The optimal node solution is obtained to find the best location and reduction capacity of ACs for load control. To demonstrate the validity and effectiveness of the proposed method, a test system is studied. The numerical results are also given in this article, which reveal that the proposed method is promising.


Symmetry ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 775
Author(s):  
Sheng-Yu Tseng ◽  
Jun-Hao Fan

Due to the advantages of power supply systems using the DC distribution method, such as a conversion efficiency increase of about 5–10%, a cost reduction of about 15–20%, etc., AC power distribution systems will be replaced by DC power distribution systems in the future. This paper adopts different converters to generate DC distribution system: DC/DC converter with PV arrays, power factor correction with utility line and full-bridge converter with multiple input sources. With this approach, the proposed full-bridge converter with soft-switching features for generating a desired voltage level in order to transfer energy to the proposed DC distribution system. In addition, the proposed soft-switching full-bridge converter is used to generate the DC voltage and is applied to balance power between the PV arrays and the utility line. Due to soft-switching features, the proposed full-bridge converter can be operated with zero-voltage switching (ZVS) at the turn-on transition to increase conversion efficiency. Finally, a prototype of the proposed full-bridge converter under an input voltage of DC 48 V, an output voltage of 24 V, a maximum output current of 21 A and a maximum output power of 500 W was implemented to prove its feasibility. From experimental results, it can be found that its maximum conversion efficiency is 92% under 50% of full-load conditions. It was shown to be suitable for DC distribution applications.