Mechanism and influence factors of hydraulic fluctuations in a pump-turbine

Author(s):  
Xiaolong Fu ◽  
Deyou Li ◽  
Hongjie Wang ◽  
Guanghui Zhang ◽  
Xianzhu Wei

Pumped-storage power technology is currently the only available energy storage technology in the grid net, and its reliability is receiving attention increasingly. However, when a pump-turbine unit undergoes runaway transitions, hydraulic fluctuations intensively affect the reliable operation of a pumped-storage power station. To reduce hydraulic fluctuations, this study investigated the formation mechanism of hydraulic fluctuations and explored its influence factors. In this study, a developed one-dimensional and three-dimensional (1 D-3D) coupling simulation method was adopted. Transient runaway transitions of a pump-turbine with three different inertias (0.5 J, 1 J, and 2.0 J) at three different guide vane openings (21°, 15°, and 12°, respectively) were simulated and compared. The results suggest that, at smaller guide vane openings (15° and 12°), water hammer owing to the increase in rotational speed is the primary unstable issue compared to the pulsation of radial hydraulic exciting forces on the runner. However, at a larger guide vane opening (21°), the latter owing to the back-flow near the runner inlet is the primary unstable issue. Moreover, it is found that a sufficiently large inertia improves the hydraulic fluctuations of the pump-storage power station, particularly in reducing the pulsation of radial hydraulic exciting loads on the runner. The findings of this study provide a valuable reference for determining suitable rotor inertia.

Author(s):  
Honggang Fan ◽  
Qingfeng Ji ◽  
Weili Liao ◽  
Haixia Yang

The unit of a Pumped Storage Power Station experienced abnormal noise and vibration in the guide vanes at the slight opening when the pump turbine was in the process of startup in the pumping mode. Based on this phenomena, the three dimensional model of the pump turbine was established, RNG k-epsilon two equations turbulence model was selected for the flow numerical simulation in the pump turbine because this model can simulate both the flow separation and vortex dynamics, and it is more accurate in the near wall areas. The governing equations were discretized with the finite volume method. The computation was carried out with three steps, 1.steady calculation, 2.unsteady calculation with constant guide vane opening, 3.unsteady calculations with the increase of the opening of guide vanes, by using the results of the last step as the initial condition. According to the three dimensional simulation results, the main flow between the guide vanes was deflected from attaching to the one vane to the other vane with the opening of the guide vanes. The calculation of complete 3D flow indicated that the deflections of the flows between the different adjacent guide vanes were basically the same, however, the deflections starting times had a few differences. The variation of the torque on the guide vane was also investigated, and the results shown the abrupt changes occurred during the deflection process of the main flow. When the torque produced by the servomotor cannot adapt quickly enough to the abrupt changes, the vibration and loud scrape noise might occur.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4732
Author(s):  
Jing Yang ◽  
Yue Lv ◽  
Dianhai Liu ◽  
Zhengwei Wang

Pumped-storage power stations play a regulatory role in the power grid through frequent transition processes. The pressure pulsation in the draft tube of the pump-turbine under transient processes is important for safe operation, which is more intense than that in the steady-state condition. However, there is no effective method to obtain the exact pressure in the draft tube in the transient flow field. In this paper, the pressure in the draft tube of a pump-turbine under steady-state and transient conditions are studied by means of CFD. The reliability of the simulation method is verified by comparing the real pressure pulsation data with the test results. Due to the distribution of the pressure pulsation in the draft tube being complex and uneven, the location of the pressure monitoring points directly affects the accurate judgement of cavitation. Eight monitoring surfaces were set in the straight cone of the draft tube and nine monitoring points were set on each monitoring surface to analyze the pressure differences on the wall and inside the center of the draft tube. The relationships between the pressure pulsation value inside the center of the draft tube and on the wall are studied. The “critical” wall pressure pulsation value when cavitation occurs is obtained. This study provides references for judging cavitation occurrences by using the wall pressure pulsation value in practical engineering.


Author(s):  
Wei Zeng ◽  
Jiandong Yang ◽  
Yongguang Cheng

Pump-turbine characteristic curves are the most important boundary condition in the hydraulic transient simulation of a pumped-storage hydropower station. Conventional representation of them, however, has serious defects, For instance, the “S” and “hump” shapes, composed of multiple values and steep twists, lead to the difficulty in interpolation between known guide-vane opening curves, which is necessary in hydraulic transient simulations. Here, a new transformation method was figured out to settle this problem thoroughly and to improve the accuracy of interpolation between the constant opening curves. Prior to the transformation, the characteristic curves are partitioned into eight domains. Curves of each domain were transformed through different formulae that fit the curves well. Eight characteristic surfaces in the 3-D space can be obtained by adding the guide vane opening as the coordinate axis. The theoretical method has been validated by the excellent agreements achieved by comparing the curves interpolated on the characteristic surfaces with the measured data.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8507
Author(s):  
Zhiyan Yang ◽  
Yongguang Cheng ◽  
Ke Liu ◽  
Xiaoxia Hou ◽  
Xiaoxi Zhang ◽  
...  

The pumped-storage power station is an efficient stability regulator of the power grid. However, due to the instability of the pump-turbine in the S-shaped characteristic region, rotational speed fluctuation is easy to occur in the speed no-load condition, making synchronization with and connection to the grid difficult. To investigate the key factors of these difficult grid connections, the start-up processes of a practical pump-turbine under the lowest head condition were simulated by using the three-dimensional CFD method, in which the governor regulating equations with different regulating parameters were integrated successfully. The results show that the working points oscillate with the fluctuations of rotational speed, discharge, and torque, and different regulating parameters have a significant influence on the dynamic histories. In addition, the internal flow patterns, especially the backflows at the runner inlet, keep apparent values at the middle span (0.5 span) but have regular transitions near the shroud side (0.7–0.8 span). The faster the guide vanes adjust, the faster the backflows change, and the larger the macro parameters fluctuate. Overall, the instability of the start-up is the result of the periodical evolutions of backflows at the runner inlet, because the trend and period of the radial velocities at different inlet span locations are consistent with those of the discharge.


2017 ◽  
Vol 20 (2) ◽  
pp. 301-315 ◽  
Author(s):  
Xiaoqin Li ◽  
Xuelin Tang ◽  
Xiaoyan Shi ◽  
Honghao Chen ◽  
Changsheng Li

Abstract It is more dangerous for the units sharing the same division pipeline system than those sharing individual system during the load rejection transient for a high water head pumped storage station. A new mathematical model for the load rejection transient in these two units sharing the same division pipeline was proposed using method of internal characteristic (MIC). The transient relationship between the geometric parameters and working parameters was established based on the dynamic equations of the hydraulic machinery. Meanwhile, the calculation of the load rejection transient was accomplished and compared with field experimental data from a pumped storage power station. The relative errors of the maximum rotational speed of the two units between the predicted results and the experimental data were −5.9% and −4.44%, respectively, and the relative errors of the maximum rising of hydraulic pressure were −6.7% and −6.98%, respectively. The results met with the design specification requirements, which indicated that the proposed new MIC could completely predict the load rejection transient in these two units with joint closing law of ball-valve and guide vane, and the corresponding calculated results were acceptable and reliable. The MIC is also applicable to the transient investigation of hydraulic systems with hydraulic machinery.


2018 ◽  
Vol 8 (11) ◽  
pp. 2193 ◽  
Author(s):  
Qin Zhou ◽  
Linsheng Xia ◽  
Chunze Zhang

The runaway oscillation process of the pump-turbine in a high head pumped-storage power plant is usually unstable. The root cause of its instability is still unclear. In this paper, its internal mechanism and the improvement method were studied in depth. First, the flow characteristics in a model pump-turbine during the runaway process at four guide-vane openings (GVOs) were investigated by 3D transient numerical simulations. Then, the energy dissipation characteristics of different types of backflow vortex structures (BFVSs) occurring at the runner inlet and their impacts on the runaway stability were investigated by the entropy production theory. The results show that the location change of BFVSs between the hub side and the mid-span of the runner inlet around the no-load point leads to the sharp change in the energy dissipation rate, which makes the slope of dynamic trajectory positive and the runaway oscillation self-excited. If the occurrence of BFVSs at the hub side is suspended, the runaway process will be damped. Finally, the pump-turbine runner was improved to obtain a wider stable operating range.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 1000 ◽  
Author(s):  
Jiawei Ye ◽  
Wei Zeng ◽  
Zhigao Zhao ◽  
Jiebin Yang ◽  
Jiandong Yang

In load rejection transitional processes in pumped-storage plants (PSPs), the process of closing pump turbines, including guide vane (GVCS) and ball valve closing schemes (BVCS), is crucial for controlling pulsating pressures and water hammer. Extreme pressures generated during the load rejection process may result in fatigue damage to turbines, and cracks or even bursts in the penstocks. In this study, the closing schemes for pump turbine guide vanes and ball valves are optimized to minimize water hammer and pulsating pressures. A model is first developed to simulate water hammer pressures and to estimate pulsating pressures at the spiral case and draft tube of a pump turbine. This is combined with genetic algorithms (GA) or non-dominated sorting genetic algorithm II (NSGA-II) to realize single- or multi-objective optimizations. To increase the applicability of the optimized result to different scenarios, the optimization model is further extended by considering two different load-rejection scenarios: full load-rejection of one pump versus two pump turbines, simultaneously. The fuzzy membership degree method provides the best compromise solution for the attained Pareto solutions set in the multi-objective optimization. Employing these optimization models, robust closing schemes can be developed for guide vanes and ball valves under various design requirements.


2014 ◽  
Vol 580-583 ◽  
pp. 3021-3025
Author(s):  
Fang Han ◽  
Dong Wang Zhong ◽  
Ji Yun Mo ◽  
Gui Juan Chen

The vibration characteristics and vibration response under different load cases in the underground powerhouse structure of Yixing pumped-storage power station were studied by establishing three-dimensional finite element model. The harmonic and transient analysis methods were proposed to study the vibration response of the powerhouse structure under various generating unit dynamic loads and in transient process. The numerical results were evaluated according to the related rules and regulations. The result shows that the vibration response of the power house structure is in the limit of the rules and regulations and there was little chance of resonance.


Mathematics ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 1465 ◽  
Author(s):  
Haiqin Song ◽  
Jinfeng Zhang ◽  
Ping Huang ◽  
Haikun Cai ◽  
Puyu Cao ◽  
...  

The pump-turbine is the core component of a pumped storage power station. This paper considers an in-depth analysis of the rotor-stator interaction characteristics under computational fluid dynamics (CFD) and experimental measurements of pump-turbine with splitter blades used in a domestic pumped storage power station. The results show that as the guide blade opening increases, the rotor-stator interaction of the pump-turbine intensifies and the magnitude of the runner radial force and its pulsation amplitude as well as the magnitude of the guide blade water moment and its pulsation amplitude also increase. In addition, when the opening degree increases from 9.8° to 17.5°, the influence on the main frequency is mainly reflected in the phase change. While the opening degree increases from 17.5° to 24.8°, the influence on the main frequency is mainly reflected in the amplitude change. Moreover, the amplitude of 5fn at opening 9.8° and opening 24.8° is greater than the optimal opening 17.5°, indicating that deviation from the optimal opening will aggravate the difference of rotor-stator interaction between splitter blades and guide blades. In the paper, the influence of guide blade openings on the rotor-stator interaction between the splitter guide blade is studied, which provides a theoretical reference for the stable operation of the pump-turbine.


Sign in / Sign up

Export Citation Format

Share Document