scholarly journals Caution in Using the Activated Partial Thromboplastin Time to Monitor Argatroban in COVID-19 and Vaccine-Induced Immune Thrombocytopenia and Thrombosis (VITT)

2021 ◽  
Vol 27 ◽  
pp. 107602962110669
Author(s):  
Susan Guy ◽  
Steve Kitchen ◽  
Michael Makris ◽  
Rhona M. Maclean ◽  
Giorgia Saccullo ◽  
...  

Introduction Argatroban is licensed for patients with heparin-induced thrombocytopenia and is conventionally monitored by activated partial thromboplastin time (APTT) ratio. The target range is 1.5 to 3.0 times the patients’ baseline APTT and not exceeding 100 s, however this baseline is not always known. APTT is known to plateau at higher levels of argatroban, and is influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. It has been used as a treatment for COVID-19 and Vaccine-induced Immune Thrombocytopenia and Thrombosis (VITT). Some recent publications have favored the use of anti-IIa methods to determine the plasma drug concentration of argatroban. Methods Plasma of 60 samples from 3 COVID-19 patients and 54 samples from 5 VITT patients were tested by APTT ratio and anti-IIa method (dilute thrombin time dTT). Actin FS APTT ratios were derived from the baseline APTT of the patient and the mean normal APTT. Results Mean APTT ratio derived from baseline was 1.71 (COVID-19), 1.33 (VITT) compared to APTT ratio by mean normal 1.65 (COVID-19), 1.48 (VITT). dTT mean concentration was 0.64 µg/ml (COVID-19) 0.53 µg/ml (VITT) with poor correlations to COVID-19 baseline APTT ratio r2 = 0.1526 p <0.0001, mean normal r2 = 0.2188 p < 0.0001; VITT baseline APTT ratio r2 = 0.04 p < 0.001, VITT mean normal r2 = 0.0064 p < 0.001. Conclusions We believe that dTT is a superior method to monitor the concentration of argatroban, we have demonstrated significant differences between APTT ratios and dTT levels, which could have clinical impact. This is especially so in COVID-19 and VITT.

Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 2275-2275
Author(s):  
Jonathan Douxfils ◽  
François Mullier ◽  
Christian Chatelain ◽  
Bernard Chatelain ◽  
Dogné Jean-Michel

Abstract Abstract 2275 Introduction: Apixaban is direct factor-Xa inhibitor that reached the market for the prevention of venous thromboembolism in patients undergoing major orthopaedic surgery. It is also being evaluated in the reduction of recurrent ischemic events when added to antiplatelet therapy after an acute coronary syndrome and in the prevention of stroke in patients with non-valvular atrial fibrillation. Thanks to its predictable pharmacokinetic profile, biological monitoring is not required. Nevertheless, evaluation of plasma drug concentration may be valuable in specific situations such as recurrent thrombosis, bleedings, before urgent surgery, in case of bridging and in case of at least two risk factors among the following ones: drug interactions with caution, moderate renal impairment and moderate hepatic impairment; Monitoring may also be useful in infants, pregnant women or in extreme body weights, although no relevant data on drug levels associated with approximate therapeutic and harmful ranges are currently available. Material and Methods: Apixaban was spiked at increasing concentrations (0, 5, 10, 20, 50, 100, 200 and 500 ng/mL) in pooled citrated normal human platelet poor plasma (PPP) to measure Prothrombin Time (PT) and dilute PT with different thromboplastin, Thrombin Generation Assay (TGA) with different inducers and activity on different anti-Xa chromogenic assays. Activated Partial Thromboplastin Time with different reagents, Thrombin Time (TT), Ecarin Clotting Time (ECT) and Reptilase Time (RT), measurement of fibrinogen (Clauss method and PT-derived method) and antithrombin (anti-IIa and anti-Xa based chromogenic assays) were also tested. We also evaluated the impact of apixaban on assays used for the determination of lupus anticoagulant such as the DRVV-T.. (Screen and Confirm) as well as the PTT-LA.. and the Staclot-LA.. . Results and Discussion: As mentioned in previous studies, PT showed a weak sensitivity towards apixaban in comparison with the plasma range obtained in short pharmacokinetic studies. Indeed, the concentration needed to double the clotting time was 154 ng/mL with the most sensitive reagent while the mean Cmax obtained in a short PK study after one oral intake of 5 mg apixaban (dose given in atrial fibrillation) was 96 ng/mL. Therefore, the sensitivity of PT is not strong enough to allow accurate quantitative measurement of the plasma drug concentration (Table 1). Activated Partial Thromboplastin Time presented a better sensitivity but showed a plateau after 100 ng/mL reflecting the uselessness of this test for the quantification of apixaban. Thrombin Time, ECT and RT were logically not affected while DRVV-T.. showed a sensitivity of 205 ng/mL (Screen), which is once again not enough sensitive. On the opposite, chromogenic anti-Xa assays seemed to be very sensitive (Figure 2 and Table 1). Nevertheless, the relation was not always linear and some methodologies needed to be adapted to ensure a broader range of application. TGA (Figure 1) may be useful to assess the pharmacodynamics effects of apixaban on the coagulation process. Nevertheless, the turn around time and the lack of standardisation are currently limitations that restrict the use of this method. In the case of the exploration of an haemorrhagic event, specific tests such as RT, fibrinogen (Clauss and PT-derived method (dFib)), TT and clotting factor activity may be used. Apixaban did not interfere with these tests. Antithrombin determination if also of importance and chromogenic anti-IIa based assays should be used in face of patients treated with apixaban to avoid misdiagnosis since an overvaluation of 12% by 100 ng/mL was shown using one chromogenic anti-Xa based assay. Conclusion: PT may not be used as screening test to assess the risk of bleedings. A more specific and sensitive assay such as chromogenic anti-Xa assays using calibrators should be used to correctly assess the concentration of apixaban. Determination of lupus anticoagulant using DRVV-T.. and PTT-LA.. or Staclot LA.. as well as the determination of antithrombin using factor-Xa based chromogenic assays, were influenced by apixaban. Finally, standardization of the time between the last intake of apixaban and the sampling is mandatory. Figures: Disclosures: No relevant conflicts of interest to declare.


1979 ◽  
Author(s):  
H. Bounameaux ◽  
G.A. Marbet ◽  
H. Airenne ◽  
E. Grossmann ◽  
B. Stanojevic ◽  
...  

In 63 plasma samples from patients under heparin we determined the heparin concentration using the chromogenic substrats S-2222 (COATEST Heparin). Thrombin time (TT), activated partial thromboplastin time (APTT), antithrombin III activity (ATIIIact) and concentration (ATIIIimm) were also measured. A good correlation was found between heparin concentration and TT (r= .850, p< .001), heparin concentration and APTT (r =669, p < .001) while the correlation coefficient r between TT and APLT was .896 (p< .001).We found a statilttically significant reduction of ATIIIact with increasing APTT (p < .05. The ATIIIact and ATIIIimm values were also lower (p < .001) in the overanticoaculated group (n=ll) than in the group with insufficient heparinisation (0.18). The mean (±SO) heparin concentration in 12 plasmas with both TT and APTT in the therapeutic range was .54 (±.15) USP-U/al, very similar to that of 13 plasma (.68 ± .46 U/al) insufficiently heparinised accordirig to the APTT. However, the TT recognised then as correctly anticoagulated. Regarding these findings and our good experience without complication by monitoring heparin therapy with TT we assume that TT is more accurate than APTT for this aim.


Author(s):  
Э.М. Гаглоева ◽  
В.Б. Брин ◽  
С.В. Скупневский ◽  
Н.В. Боциева ◽  
Т.В. Молдован

Цель исследования - изучить состояние системы гемостаза при хронической интоксикации хлоридом никеля, исследовать взаимосвязь показателей гемокоагуляции с процессами липопероксидации у крыс в эксперименте. Методика. Опыты проводили на крысах-самцах Вистар (n=50, 230-250 г). Раствор NiCl2 (5 мг/кг) вводили внутрижелудочно ежедневно в течение 2 нед, 1 и 2 мес. По завершении эксперимента исследовали состояние тромбоцитарного и коагуляционного звеньев гемостаза, антикоагулянтную и фибринолитическую активность крови, а также определяли активность процессов перекисного окисления липидов и антиоксидантных ферментов. Результаты. Установлено, что через 2 нед и 1 мес интоксикации у крыс отмечались гиперкоагуляционные изменения показателей свертывающей системы крови: повышение агрегационной активности тромбоцитов, увеличение концентрации фибриногена, снижение активированного частичного тромбопластинового времени (АЧТВ) и протромбинового времени. В этот период регистрировалось увеличение антитромбиновой и фибринолитической активности крови. Через 2 мес наблюдалось подавление активности клеточного звена гемостаза - тромбоцитопения, ослабление степени АДФ-индуцируемой агрегации тромбоцитов. Выявлялась тенденция к уменьшению концентрации фибриногена. На фоне снижения АЧТВ и тромбинового времени отмечалось увеличение протромбинового времени. В то же время регистрировалось угнетение противосвертывающего звена системы гемостаза (снижалась активность антитромбина III), наблюдалось истощение резервных возможностей фибринолитического звена (замедление фXIIа-зависимого эуглобулинового лизиса) и увеличение содержания растворимых фибрин мономерных комплексов, что свидетельствует о наличии тромбинемии. Через 2 нед, один и два месяца интоксикации у животных выявлялись корреляционные связи между основными показателями системы гемостаза и активностью процессов перекисного окисления липидов и антиоксидантных ферментов. Заключение. Полученные данные подтверждают наличие взаимосвязи активности процессов липопероксидации и системы гемостаза, в том числе при хронической никелевой интоксикации. Результаты исследования позволяют рекомендовать применение антиоксидантов для разработки способов коррекции гемостатических сдвигов при воздействии на организм тяжелых металлов. The aim. To study the state of the hemostasis system in chronic nickel intoxication and to investigate the relationship between hemocoagulation indices and lipoperoxidation processes in rats. Methods. Experiments were carried out on male Wistar rats (n=50, 230-250 g). A solution of nickel chloride (5 mg/kg) was administered daily intragastrically for two weeks, one and two months. At the end of the experiments, indices of platelet and coagulation hemostasis systems, anticoagulant and fibrinolytic activity of blood plasma, and activities of lipid peroxidation and antioxidant enzymes were studied. Results. Hypercoagulative changes in indices of the coagulation system were observed in rats after two weeks and one month of intoxication, including increased platelet aggregation and fibrinogen concentration and shortened activated partial thromboplastin time and prothrombin time. During the same period, increased antithrombin and fibrinolytic activities were observed. The depressed activity of the cellular component of hemostasis evident as thrombocytopenia and impaired ADP-induced platelet aggregation was detected after two months of intoxication. A tendency to decrease in fibrinogen concentration was observed. The shortened activated partial thromboplastin time and thrombin time were associated with prolonged prothrombin time. At the same time, inhibition of the anticoagulant component of hemostasis (decreased antithrombin III activity), exhaustion of the fibrinolysis system reserve (delayed fXIIa-dependent euglobulin lysis), and a significant increase in soluble fibrin monomeric complexes indicative of thrombinemia were observed. After two weeks, one and two months of nickel intoxication, a correlation was found between the major indices of the hemostasis system and the activities of lipid peroxidation and antioxidant enzymes. Conclusion. The study confirmed a relationship between the lipid peroxidation activity and the hemostasis system, specifically in chronic nickel intoxication. This result allows to recommend the use of antioxidants in developing methods for correction of hemostatic induced affected by heavy metals.


1984 ◽  
Vol 12 (01n04) ◽  
pp. 116-123 ◽  
Author(s):  
Jih-Pyang Wang ◽  
Mei-Feng Hsu ◽  
Che-Ming Teng

Bleeding time in rats was markedly prolonged after the adminstration of the water extract of Hsien-Ho-T'sao. This antihemostatic effect was more marked in the group of i.p. injection of the drug than in the group of p.o. administration for 2 to 7 consecutive days. Blood coagulation studies showed that plasma prothrombin time, activated partial thromboplastin time and stypven time were prolonged, while thrombin time adnd fibrinogen level were not changed. The thromboelastographic recording showed that reation time was prolonged and maximal elasticity of clot was decreased. In addition, ADP- and collagen- induced aggregations of platelet-rich plasma was suppressed. In conclusion, the prolongation of the bleeding time might be due to both anticoagulant and antiplatelet action of the drug.


2021 ◽  
Vol 121 (1) ◽  
pp. 22-31
Author(s):  
Alіna Baylo ◽  
Vadym Shypulіn ◽  
Volodymyr Chernyavskyi ◽  
Luiza Parunyan

The comorbid course of liver cirrhosis and atrial fibrillation causes higher levels of hospitalizations, mortality and ischemic stroke. According to current data, hemostasis in patients with liver cirrhosis is in a rebalanced dynamic state, but there are no data on the effect of atrial fibrillation on the hemostasis in patients with liver cirrhosis. Aims of the study. To assess abnormalities in primary, secondary haemostasis and fibrinolytic system in patients with liver cirrhosis and atrial fibrillation by using standard laboratory coagulation parameters and to investigate their changes depending on the stage of liver cirrhosis A, B, C according to Child-Pugh score. Materials and methods. A cross-sectional prospective study was conducted with the inclusion of 106 patients aged 42 to 83 years: group I (n = 70) - with liver cirrhosis and atrial fibrillation, II (n = 36) - with liver cirrhosis, which were distributed depending on the Child-Pugh score stages of cirrhosis and 20 healthy individuals. The levels of platelets, activated partial thromboplastin time, international normalized ratio, prothrombin time, thrombin time, fibrinogen, D-dimer were assessed on a Steellex M200 coagulometer. Statistical analysis (IBM SPSS Statistics) was performed. Results. The level of platelets in patients of group I was reduced by 37.4% (200 ± 8.33 vs. 274.7 ± 3.4; p,000.001), an activated partial thromboplastin time was prolonged by 38.6% (44.35 ± 1.39 vs. 32.01 ± 0.63, p˂0.001), prothrombin time was prolonged by 73.5% (19.4 ± 0.87 vs. 11.18 ± 0.53, p˂0.001), thrombin time was prolonged by 2.07 (25, 7 ± 1.31 vs. 12.4 ± 0.66, p˂0.001), the international normalized ratio was increased by 24.3% (1.38 ± 0.04 vs.1.11 ± 0.01, p˂0.001) compared to control. The fibrinogen level was 20.9% higher (4.17 ± 0.17 vs. 3.45 ± 0.11, p˂0.001) than in control group and was 83.7% higher (4.17 ± 0.17 vs. 2.27 ± 0.13, p˂0.001) than in group II. The D-dimer level was 83% higher than in control (675 ± 22.3 vs. 368.8 ± 21.85, p˂0.001) and 44% higher (675 ± 22.3 vs. 469 ± 37.18, p ˂0.001) compared with group II. Conclusions. In patients with liver cirrhosis and atrial fibrillation abnormalities of primary hemostasis are detected due to decrease of platelets on the background of portal hypertension. At the secondary stage of hemostasis indicators of external and internal coagulation mechanisms are prolonged due to the reduced synthesis of coagulation factors by the liver. Increased level of fibrinogen is determined at the stage of compensated and subcompensated cirrhosis with a gradual decrease at the stage of decompensation. The high activity of the fibrinolytic system is observed due to increase in the D-dimer levels, which may indicate a prothrombotic state in these patients.


2007 ◽  
Vol 131 (2) ◽  
pp. 293-296
Author(s):  
Alexander Kratz ◽  
Raneem O. Salem ◽  
Elizabeth M. Van Cott

Abstract Context.—Technologic advances affecting analyzers used in clinical laboratories have changed the methods used to obtain many laboratory measurements, and many novel parameters are now available. The effects of specimen transport through a pneumatic tube system on laboratory results obtained with such modern instruments are unclear. Objective.—To determine the effects of sample transport through a pneumatic tube system on routine and novel hematology and coagulation parameters obtained on state-of-the-art analyzers. Design.—Paired blood samples from 33 healthy volunteers were either hand delivered to the clinical laboratory or transported through a pneumatic tube system. Results.—No statistically significant differences were observed for routine complete blood cell count and white cell differential parameters or markers of platelet activation, such as the mean platelet component, or of red cell fragmentation. When 2 donors who reported aspirin intake were excluded from the analysis, there was a statistically, but not clinically, significant impact of transport through the pneumatic tube system on the mean platelet component. There were no statistically significant differences for prothrombin time, activated partial thromboplastin time, waveform slopes for prothrombin time or activated partial thromboplastin time, fibrinogen, or fibrin monomers. Conclusions.—Although further study regarding the mean platelet component may be required, transport through a pneumatic tube system has no clinically significant effect on hematology and coagulation results obtained with certain modern instruments in blood samples from healthy volunteers.


2020 ◽  
Vol 42 (3) ◽  
Author(s):  
Erica Scalambrino ◽  
Lidia Padovan ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Andrea Artoni ◽  
...  

2001 ◽  
Vol 94 (2) ◽  
pp. 245-251 ◽  
Author(s):  
Andreas Koster ◽  
Marian Kukucka ◽  
Friedhelm Bach ◽  
Oliver Meyer ◽  
Thomas Fischer ◽  
...  

Background Patients with heparin-induced thrombocytopenia type II require an alternative to standard heparin anticoagulation. However, in patients with renal impairment, anticoagulation during cardiopulmonary bypass with agents such as danaparoid sodium or r-hirudin are associated with hemorrhage. Anticoagulation with unfractionated heparins combined with prostacyclin, a potent platelet aggregation inhibitor, is associated with severe hypotension. The authors investigated a new concept using unfractionated heparins after platelet inhibition with the short-acting platelet glycoprotein IIb-IIIa antagonist tirofiban. Methods Ten patients with heparin-induced thrombocytopenia type II and renal impairment were enrolled in the investigation. All had heparin-induced thrombocytopenia type II antibodies present as proved by the heparin-induced platelet aggregation assay, the heparin-platelet factor 4 enzyme-linked immunosorbent assay, or both. In all patients, preoperative anticoagulation to an activated partial thromboplastin time of 40-60 s was performed with r-hirudin. Anticoagulation during cardiopulmonary bypass was achieved with a bolus of 400 IU/kg unfractionated heparins after a bolus of tirofiban 10 microg/kg followed by an infusion of tirofiban at a rate of 0.15 microg x kg(-1) x min(-1) until 1 h before conclusion of cardiopulmonary bypass. Additional unfractionated heparins were only administered if activated clotting time decreased below 480 s. Coagulation was monitored by a abciximab-modified TEG and the adenosine diphosphate-stimulated (20 microm) platelet aggregometry. D-dimer concentrations, as a marker of venous thromboembolism, were measured before and 12, 24, and 48 h after surgery. Postoperative antithrombotic therapy was started immediately with r-hirudin to anticoagulation to an activated partial thromboplastin time of 40-60 s. Results The postoperative blood loss ranged from 110 to 520 ml. No patient needed reexploration. In no patient was there clinical evidence of thrombosis or embolism in the postoperative period or of a critical increase of the D-dimer concentrations, suggesting venous thromboembolism. Transfusion of platelets was necessary in only two patients. Conclusions The protocol is easy to perform and no increased postoperative bleeding and no thromboembolic complications occurred. The combination of unfractionated heparins and tirofiban may be an alternative to other anticoagulation strategies in patients with heparin-induced thrombocytopenia.


2019 ◽  
Vol 29 (2) ◽  
pp. 385-393
Author(s):  
Chuen Wen Tan ◽  
McVin Hua Heng Cheen ◽  
Heng Joo Ng ◽  
Lai Heng Lee ◽  
Sahul Hameed Ahamedulla ◽  
...  

Introduction: A hypercoagulable state is a predisposition for venous thromboembolism (VTE). The activated partial thromboplastin time (aPTT)-based clot waveform analysis (CWA) is a global haemostatic measure but its role in assessment of hypercoagulability and thrombotic disorders is uncertain. We aimed to study the changes of CWA parameters in acute VTE. We hypothesized that patients with acute VTE would demonstrate higher CWA values than control patients without VTE and having elevated CWA parameters is associated with acute VTE. Materials and methods: Clot waveform analysis data from patients (N = 45) with objectively proven acute VTE who had an aPTT performed prior to initiation of anticoagulation were compared with controls (N = 111). The CWA parameters measured were min1, min2, max2 and delta change. Results: While the mean aPTT between VTE patients and controls did not differ (P = 0.830), the mean CWA parameters were significantly higher among VTE patients than controls (min1, P < 0.001; min2, P = 0.001; max2, P = 0.002; delta change, P < 0.001). There were significantly more cases within the VTE group exhibiting CWA values above their reference intervals than the control group (all P < 0.001), with the odds ratios for VTE of 8.0, 5.2, 4.8 and 18.6 for min1, min2, max2 and delta change, respectively (all P < 0.001). Conclusions: Patients with acute VTE had elevated aPTT-based CWA parameters than controls. Higher CWA parameters were significantly associated with acute VTE.


Sign in / Sign up

Export Citation Format

Share Document