Seismic fragility analysis of two-story ultra-high ductile cementitious composites frame without steel reinforcement

2020 ◽  
Vol 23 (11) ◽  
pp. 2373-2387
Author(s):  
Fangyuan Dong ◽  
Jiangtao Yu ◽  
Kaili Zhan ◽  
Zhanhong Li

This article numerically studies the seismic vulnerability of the frame structure made of ultra-high ductile cementitious composites without longitudinal and transverse reinforcement. A non-linear finite element model is established with the help of Open System for Earthquake Engineering Simulation and calibrated by shaking table test results on an ultra-high ductile cementitious composite-RC frame whose seismic vulnerable parts were replaced by ultra-high ductile cementitious composites without steel reinforcement. Subsequently, an analysis on the structural seismic vulnerability is performed on pure ultra-high ductile cementitious composite frame structure based on the incremental dynamic analysis method. Finally, a seismic vulnerability matrix of the ultra-high ductile cementitious composite frame under various structural limit states is obtained from seismic fragility curves. Under the major earthquake of magnitude 7.5, the probability of ultra-high ductile cementitious composite frame structure under basically intact, slight damage, moderate damage, serious damage, and collapse is 14.2%, 48.1%, 31.7%, 5.3%, and 0.7%, respectively. The achieved results also demonstrate that the ultra-high ductile cementitious composite frame can satisfy the objectivity of “No collapsed under major earthquake” at least for major earthquakes of magnitude 8. It is demonstrated that the ultra-high ductile cementitious composite frame satisfies three-level performance objectivity stipulated in GB 50011-2010 and, thus, preliminarily verifying the feasibility for constructing structures just using high-performance concrete.


2010 ◽  
Vol 23 (1) ◽  
pp. 45-52 ◽  
Author(s):  
Jingbo Liu ◽  
Yangbing Liu ◽  
Heng Liu


2021 ◽  
Vol 233 ◽  
pp. 03022
Author(s):  
Yucheng LI ◽  
Wei WANG ◽  
Xing WANG

The research on the mechanical characteristics of concrete-filled steel tubular composite frame under high temperature fire environment is one of the research hotspots. In this paper, the finite element simulation software is used to analyze the concrete-filled steel tubular composite frame structure. The failure mode of the flexural deformation of the composite frame structure under high temperature fire environment is introduced. The simulation results of the deformation and displacement of the single-layer single span and two-layer two-span composite frame structure are deeply studied, including the different temperature field, structural field, structural field of each beam and column The results show that: with the temperature rising, the horizontal plastic strain, vertical displacement and local plastic region of beam and column are redistributed and changed in high temperature fire environment, and the flexural effect of two-story two-span concrete-filled steel tubular composite frame under different fire positions is analyzed. The results show that: with the temperature rising, the horizontal plastic strain at the concentrated load is not the results show that the deflection and deformation redistribution are obvious, and the deflection and deformation redistribution are obvious at the joint points of beams and columns. Finally, a mechanism is formed and destroyed. The flexure effect of mode 1 is larger than that of condition 2, which indicates that the flexural effect of two-story two span CFST composite frame under full cross-section fire is larger than that of condition 2 It should be better. The research results can provide reference value for the reinforcement and repair of CFST composite frame under high temperature fire.



2016 ◽  
Vol 20 (4) ◽  
pp. 491-503 ◽  
Author(s):  
Fang Yuan ◽  
Jinlong Pan ◽  
Christopher KY Leung

Engineered cementitious composite is a class of high-performance cementitious composites with pseudo-strain hardening behavior and excellent crack control capacity. Substitution of concrete with engineered cementitious composite can greatly reduce the cracking and durability problems associated with low tensile strength and brittleness of concrete and can significantly increase structural seismic resistance. In this article, a pair of beam–column joints with various matrix types has been tested under reversed cyclic loading to study the effect of substitution of concrete with engineered cementitious composite in the joint zone on the seismic behaviors of composite members. After that, a simplified constitutive model of engineered cementitious composite under cyclic loading is proposed, and the structural performance of steel reinforced engineered cementitious composite members is simulated by fiber beam elements. The accuracy of the model is verified with test data. Finally, three frame structures with different matrixes subjected to earthquake actions were numerically modeled to verify the contribution of ductile engineered cementitious composite material to structural seismic resistance. The seismic responses or failure mechanisms, deformation patterns, and energy dissipation capacities for each frame structure are analyzed and compared. The simulation results indicate that the application of engineered cementitious composite can reduce the maximum story drift ratio, and the distributions of the dissipated energy are more uniform along the building height when engineered cementitious composite is strategically used in ground columns and beam–column joints of the frame structure. The seismic performance of the reinforced engineered cementitious composite-concrete composite frame is found to be even better than the frame with all concrete replaced by engineered cementitious composite.



2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Youquan Liu ◽  
Jingang Xiong ◽  
Jiancong Wen

Progressive collapse behavior of case-in-place concrete and steel frame structures has been extensively investigated over the past years. However, studies on progressive collapse resistance and characteristics of prefabricated RCS composite frame structure (space frame) are limited. In this study, a half-scale prefabricated RCS space frame structure (two-storey, 1 × 2-bay) was designed and manufactured and then tested through the sudden failure of the long-side central column. The weakened part of failure column was rapidly pulled out using vehicle traction force, and displacement was obtained with a dynamic data acquisition instrument supplemented by high-speed camera to record the deformation process of the structure. Additionally, the remaining structure displacement variation and the beam-to-column connections of fem model under progressive collapse were simulated using SAP2000. The FEA results were compared with the experimental results to verify the effectiveness of the numerical analysis. Experimental results demonstrated that the prefabricated RCS composite frame structure designed in accordance with Chinese building codes shows improved resistance to progressive collapse. The dynamic effect demonstrates no significant influence on the prefabricated RCS composite frame structure, and the suggested dynamic amplification coefficient is 1.28. Steel plates (A, B, and C) of the beam-to-column connection are the weak part of the structural failure, and appropriate measures should be applied to strengthen the steel plate of the beam-to-column connection when the prefabricated RCS composite frame structure is designed to resist progressive collapse. SAP2000 FEM program verified that the numerical simulation results are basically consistent with the experimental results.



Materials ◽  
2017 ◽  
Vol 10 (11) ◽  
pp. 1340 ◽  
Author(s):  
Sang-Hyo Kim ◽  
Kun-Soo Kim ◽  
Do-Hoon Lee ◽  
Jun-Seung Park ◽  
Oneil Han


2007 ◽  
Vol 80 (1) ◽  
pp. 105-116 ◽  
Author(s):  
Haibin Ning ◽  
Uday Vaidya ◽  
Gregg M. Janowski ◽  
George Husman


Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4095
Author(s):  
Qing Chen ◽  
Zhiyuan Zhu ◽  
Rui Ma ◽  
Zhengwu Jiang ◽  
Yao Zhang ◽  
...  

In this paper, the mechanical performance of an ultra-high-performance concrete (UHPC) repaired cementitious composite system, including the old matrix and the new reinforcement (UHPC), under various high temperature levels (20 °C, 100 °C, 300 °C, and 500 °C) was studied. In this system, UHPC reinforced with different contents of steel fibers and polypropylene (PP) fibers was utilized. Moreover, the physical, compressive, bonding, and flexural behaviors of the UHPC repaired system after being exposed to different high temperatures were investigated. Meanwhile, X-ray diffraction (XRD), baseline evaluation test (BET), and scanning electron microscope (SEM) tests were conducted to analyze the effect of high temperature on the microstructural changes in a UHPC repaired cementitious composite system. Results indicate that the appearance of the bonded system changed, and its mass decreased slightly. The average percentage of residual mass of the system was 99.5%, 96%, and 94–95% at 100 °C, 300 °C, and 500 °C, respectively. The residual compressive strength, bonding strength, and flexural performance improved first and then deteriorated with the increase of temperature. When the temperature reached 500 °C, the compressive strength, bonding strength, and flexural strength decreased by about 20%, 30%, and 15% for the UHPC bonded system, respectively. Under high temperature, the original components of UHPC decreased and the pore structure deteriorated. The cumulative pore volume at 500 °C could reach more than three times that at room temperature (about 20 °C). The bonding showed obvious deterioration, and the interfacial structure became looser after exposure to high temperature.



Sign in / Sign up

Export Citation Format

Share Document