scholarly journals Anti-icing hot air jet heat transfer augmentation employing inner channels

2021 ◽  
Vol 13 (12) ◽  
pp. 168781402110662
Author(s):  
Farooq Saeed ◽  
Kamran Z Ahmed ◽  
Amro OE Owes ◽  
Ion Paraschivoiu

Many approaches exist today that employ hot-air from aircraft compressor bleed for anti-icing critical aircraft surfaces. This paper introduces and numerically analyzes the novel application of an inner or etched channel to augment heat transfer from a hot-air jet impinging on a curved surface representing the inner surface of an aircraft wing’s leading edge or slat. The study shows that proper positioning, geometry, and flow characteristics of a channel along the inner surface of the leading edge can significantly enhance heat transfer, boost the anti-icing system performance, and greatly enhance flight safety during critical icing weather conditions. Commercially available CFD software, ANSYS Fluent is used to model and analyze the effect of different geometric and flow parameters typical of those found in small to medium category commercial transport aircraft to help determine the optimum arrangement. These parameters include: (1) jet nozzle height-to-slot diameter ratios from 4 to 8, (2) channel width-to-slot diameter ratios from 0.4 to 1.8, and (3) inner-channel inlet location angles from 10° to 60°. Each configuration resulting from a combination of the above parameters was simulated at Reynolds numbers based on jet-slot diameter of 30,000, 60,000, and 90,000. Empirical relations based on available experimental data are used to validate the results. The main findings of the study reveal that the jet height-to-slot diameter ratio of 6, inner channel height-to-slot diameter ratios of 1.8, and inner-channel inlet angular locations of 10° combination resulted in the highest heat transfer at all Reynolds number as well as higher at increased Reynold numbers.

Author(s):  
C. R. Hedlund ◽  
P. M. Ligrani ◽  
H.-K. Moon ◽  
B. Glezer

Heat transfer and fluid mechanics results are given for a swirl chamber whose geometry models an internal passage used to cool the leading edge of a turbine blade. The Reynolds numbers investigated, based on inlet duct characteristics, include values which are the same as in the application (18000–19400). The ratio of absolute air temperature between the inlet and wall of the swirl chamber ranges from 0.62 to 0.86 for the heat transfer measurements. Spatial variations of surface Nusselt numbers along swirl chamber surfaces are measured using infrared thermography in conjunction with thermocouples, energy balances, digital image processing, and in situ calibration procedures. The structure and streamwise development of arrays of Görtler vortex pairs, which develop along concave surfaces, are apparent from flow visualizations. Overall swirl chamber structure is also described from time-averaged surveys of the circumferential component of velocity, total pressure, static pressure, and the circumferential component of vorticity. Important variations of surface Nusselt numbers and time-averaged flow characteristics are present due to arrays of Görtler vortex pairs, especially near each of the two inlets, where Nusselt numbers are highest. Nusselt numbers then decrease and become more spatially uniform along the interior surface of the chamber as the flows advect away from each inlet.


2017 ◽  
Vol 21 (1 Part A) ◽  
pp. 279-288 ◽  
Author(s):  
Shuxia Qiu ◽  
Peng Xu ◽  
Liping Geng ◽  
Arun Mujumdar ◽  
Zhouting Jiang ◽  
...  

Air jet impingement is one of the effective cooling techniques employed in micro-electronic industry. To enhance the heat transfer performance, a cooling system with air jet impingement on a finned heat sink is evaluated via the computational fluid dynamics method. A two-dimensional confined slot air impinging on a finned flat plate is modeled. The numerical model is validated by comparison of the computed Nusselt number distribution on the impingement target with published experimental results. The flow characteristics and heat transfer performance of jet impingement on both of smooth and finned heat sinks are compared. It is observed that jet impingement over finned target plate improves the cooling performance significantly. A dimensionless heat transfer enhancement factor is introduced to quantify the effect of jet flow Reynolds number on the finned surface. The effect of rectangular fin dimensions on impingement heat transfer rate is discussed in order to optimize the cooling system. Also, the computed flow and thermal fields of the air impingement system are examined to explore the physical mechanisms for heat transfer enhancement.


2007 ◽  
Vol 129 (12) ◽  
pp. 1732-1736 ◽  
Author(s):  
Rong Fung Huang ◽  
Shyy Woei Chang ◽  
Kun-Hung Chen

The flow characteristics and the heat transfer properties of the rectangular channels with staggered transverse ribs on two opposite walls are experimentally studied. The rib height to channel height ratio ranges from 0.15 to 0.61 (rib height to channel hydraulic diameter ratio from 0.09 to 0.38). The pitch to rib height ratio covers from 2.5 to 26. The aspect ratio of the rectangular channel is 4. The flow characteristics are studied in a water channel, while the heat transfer experiments are performed in a wind tunnel. Particle image velocimetry (PIV) is employed to obtain the quantitative flow field characteristics. Fine-wire thermocouples imbedded near the inner surface of the bottom channel wall are used to measure the temperature distributions of the wall and to calculate the local and average Nusselt numbers. Using the PIV measured streamline patterns, various characteristic flow modes, thru flow, oscillating flow, and cell flow, are identified in different regimes of the domain of the rib height to channel height ratio and pitch to rib height ratio. The vorticity, turbulence intensity, and wall shear stress of the cell flow are found to be particularly larger than those of other characteristic flow modes. The measured local and average Nusselt numbers of the cell flow are also particularly higher than those of other characteristic flow modes. The distinctive flow properties are responsible for the drastic increase of the heat transfer due to the enhancement of the momentum, heat, and mass exchanges within the flow field induced by the large values of the vorticity and turbulence intensity. Although the thru flow mode is conventionally used in the ribbed channel for industrial application, the cell flow could become the choice if the heat transfer rate, instead of the pressure loss, is the primary concern.


1999 ◽  
Vol 121 (4) ◽  
pp. 804-813 ◽  
Author(s):  
C. R. Hedlung ◽  
P. M. Ligrani ◽  
H.-K. Moon ◽  
B. Glezer

Heat transfer and fluid mechanics results are given for a swirl chamber whose geometry models an internal passage used to cool the leading edge of a turbine blade. The Reynolds numbers investigated, based on inlet duct characteristics, include values that are the same as in the application (18,000–19,400). The ratio of absolute air temperature between the inlet and wall of the swirl chamber ranges from 0.62 to 0.86 for the heat transfer measurements. Spatial variations of surface Nusselt numbers along swirl chamber surfaces are measured using infrared thermography in conjunction with thermocouples, energy balances, digital image processing, and in situ calibration procedures. The structure and streamwise development of arrays of Go¨rtler vortex pairs, which develop along concave surfaces, are apparent from flow visualizations. Overall swirl chamber structure is also described from time-averaged surveys of the circumferential component of velocity, total pressure, static pressure, and the circumferential component of vorticity. Important variations of surface Nusselt numbers and time-averaged flow characteristics are present due to arrays of Go¨rtler vortex pairs, especially near each of the two inlets, where Nusselt numbers are highest. Nusselt numbers then decrease and become more spatially uniform along the interior surface of the chamber as the flows advect away from each inlet.


2000 ◽  
Author(s):  
Vijay K. Garg

Abstract The coolant flow characteristics at the hole exits of a film-cooled blade are derived from an earlier analysis where the hole pipes and coolant plenum were also discretized. The blade chosen is the VKI rotor with three staggered rows of shower-head holes. The present analysis applies these flow characteristics at the shower-head hole exits. A multi-block three-dimensional Navier-Stokes code with Wilcox’s k-ω model is used to compute the heat transfer coefficient on the film-cooled turbine blade. A reasonably good comparison with the experimental data as well as with the more complete earlier analysis where the hole pipes and coolant plenum were also gridded is obtained. If the 1/7th power law is assumed for the coolant flow characteristics at the hole exits, considerable differences in the heat transfer coefficient on the blade surface, specially in the leading-edge region, are observed even though the span-averaged values of h match well with the experimental data. This calls for span-resolved experimental data near film-cooling holes on a blade for better validation of the code.


Author(s):  
Alan McGuinn ◽  
Tadhg S. O’Donovan ◽  
Darina B. Murray

The implementation of synthetic jets for use in the cooling of electronics is a relatively new technology. It is well established that effective rates of cooling can be achieved using conventional steady flow impinging jets. However it has been shown that synthetic jets can deliver similar cooling effects without the need for an air supply system and therefore represent an extremely promising alternative for thermal management applications. A study has been undertaken of the heat transfer distribution to an impinging synthetic jet flow. The jet is directed at a heated copper plate, which approximates a uniform wall temperature. Nusselt number profiles generated by the synthetic jet for various Reynolds numbers and heights above the plate were obtained. Time varying velocity measurements were also carried out to provide information about the flow characteristics of the synthetic jet and to aid with evaluation of the heat transfer data. For continuous jets mean heat transfer distributions have been shown to have a direct relation to jet velocity profiles, however, for synthetic jets fluctuations in local heat flux illustrate a significant dependence on the driving frequency.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
Christopher LeBlanc ◽  
Srinath V. Ekkad ◽  
Tony Lambert ◽  
Veera Rajendran

Detailed Nusselt number distributions are presented for a gas turbine engine similar internal channel geometry used for cooling a modern first stage rotor blade. The cooling design has one leading edge channel and a three-pass channel that covers the rest of the blade. The simulated model, generated from the midspan section of an actual cooling circuit, was studied for wall heat transfer coefficient measurements using the transient liquid crystal technique. The model wall inner surfaces were sprayed with thermochromic liquid crystals, and a transient test was used to obtain the local heat transfer coefficients from the measured color change. Results are presented for a nominal channel inlet leading edge channel Reynolds number of 10,700 and a channel inlet three-pass channel Reynolds number of 25,500. Detailed heat transfer measurements are presented for the simulated leading edge, first pass, second pass and third pass interior walls for different rib configurations. The channels were studied for smooth, 90 deg ribs, and angled ribs geometries in addition to ribs on the divider walls between adjacent passages. Overall pressure drop measurements were also obtained for each passage. Some of these results are compared with the predicted heat transfer from standard correlations used in design practices. Results show very complicated heat transfer behavior in these realistic channels compared to results obtained in simplistic geometry channels from published studies. In some cases, the Nusselt numbers predicted by correlations are 50–60% higher than obtained from the current experiments.


Author(s):  
W. M. Chakroun ◽  
S. F. Al-Fahed ◽  
A. A. Abdel-Rehman

An experimental investigation of heat transfer from round air jet impinging normally from below on flat square plates was performed. Smooth and rough plates were used to collect heat transfer data as well as velocity and turbulence intensity profiles. The heat transfer data have been collected for Reynolds numbers ranging from 6500 to 19000. The nozzle-to-plate distances ranged from 0.05 to 15 to cover both the potential core of the jet and the far region. The study was made to investigate the effect of roughness on the local and average heat transfer values and on the fluid characteristics. The roughness was composed of cubes of 1mm dimension distributed uniformly along the plate. The local and average Nusselt numbers for the rough plate showed an increase ranging from 8.9% to 28 % over those obtained for the smooth plate. Roughness was seen to have a strong effect on the flow characteristics, it affected the mean velocity as well as the turbulence intensity of the flow. The mean velocity profiles for the smooth case at r/D = 1 and r/D = 2.5 had steeper near-wall velocity gradient compared with the rough case. Roughness caused an increase in the turbulence intensity of the flow.


Sign in / Sign up

Export Citation Format

Share Document