The Effect of Cooling Times on the Bonding Between Porcelain and Metal Alloys Fabricated by Different Techniques: In Vitro Study

2021 ◽  
pp. 232020682110371
Author(s):  
Emine Ünal ◽  
Faik Tugut

Aim: The aim of this study was to evaluate the effect of different cooling times on shear bond strength between cobalt–chromium metal frameworks fabricated by different techniques and veneering porcelain. Materials and Methods: One hundred twenty cobalt–chromium metal ceramic samples were obtained by three different techniques (casting, milling, and laser sintering). During the porcelain firing, fast and slow cooling protocols were applied. Ten specimens from each group were determined for all groups. The shear bond strength of the metal ceramic samples was measured by a universal testing machine with a constant crosshead speed of 0.5 mm/min. One sample from each group was evaluated by the scanning electron microscopy analysis in terms of surface change and fracture morphology. Variance analysis and Tukey test were used to analyze statistically significant differences between groups. Results: It was seen that the difference between the bond strengths of the metal frameworks obtained by different techniques was statistically significant ( P < .05). All groups except for difference between the bond strengths of all the frameworks metal groups with G-Ceram porcelain were statistically significant ( P < .05). The best bond strengths that were statistically significant were fast cooling G-Ceram (19.65 ± 2.65 MPa) with metal frameworks fabricated by laser sintering, fast cooling with metal framework fabricated by milling Noritake (19.17 ± 2.91 MPa), and the metal framework fabricated by casting was found to be slow cooling Noritake (12.99 ± 2.08 MPa) were seen. Conclusion: The porcelain cooling times had significant effect on the shear bond strength of porcelain to casting, milling and laser sintering alloys.

Author(s):  
Sílvia Fontes Do Amaral Pereira

O objetivo do presente estudo in vitro foi verificar, através de teste de cisalhamento, a resistência de união da liga Wironia®light, à base de níquel-cromo sem berílio, sujeita a diferentes tratamentos de superfície, às cerâmicas Vita VM13 e Noritake. Foram confeccionados oitenta espécimes cilíndricos metálicos, com o auxílio de uma matriz de aço, nas dimensões de 4 mm de diâmetro por 4 mm de altura. Os espécimes foram divididos em oito grupos (n=10), de acordo com o tipo de tratamento superficial aplicado à liga metálica e com o tipo de cerâmica testada. Estes foram avaliados de acordo com os critérios de resistência ao cisalhamento e, com o auxílio de microscopia óptica, foi avaliada a área de cerâmica remanescente aderida ao metal após a fratura. Os corpos-de-prova do G6 (fabricados em Cerâmica Noritake com jateamento-26,401 ± 11,637 MPa) apresentaram maior resistência ao cisalhamento (p> 0,05) enquanto que os menores valores foram registrados no G4 (Cerâmica Vita com utilização de broca-13,440 ± 7,766 MPa). G6 (19425,4 μm2) apresentou a maior área de cerâmica aderida ao metal (p> 0,05) enquanto que o G4 (2310,2 μm2) apresentou a menor área. Concluiu-se que G6 obteve os valores mais altos de resistência ao cisalhamento e de remanescente cerâmico aderido à superfície metálica enquanto que o G4 obteve os valores mais baixos. Descritores: Restaurações metalo-cerâmicas; ligas de níquel-cromo;porcelana dentária.


2014 ◽  
Vol 85 (4) ◽  
pp. 645-650 ◽  
Author(s):  
Laura Mews ◽  
Matthias Kern ◽  
Robert Ciesielski ◽  
Helge Fischer-Brandies ◽  
Bernd Koos

ABSTRACT Objective:  To examine differences in the shear bond strength of orthodontic brackets on differently mineralized enamel surfaces after applying a caries infiltrant or conventional adhesive. Materials and Methods:  A total of 320 bovine incisors were assigned to eight pretreated groups, and the shear force required for debonding was recorded. Residual adhesive was evaluated by light microscopy using the adhesive remnant index. Statistical analysis included Kolmogorov-Smirnov, analysis of variance (ANOVA), and Scheffé tests. Results:  The highest bond strength (18.8 ± 4.4 MPa) was obtained after use of the caries infiltrant. More residual adhesive and fewer enamel defects were observed on infiltrated enamel surfaces. Brackets on demineralized enamel produced multiple enamel defects. Conclusions:  Acceptable bond strengths were obtained with all material combinations. A caries-infiltrant applied before bracket fixation has a protective effect, especially on demineralized enamel.


2007 ◽  
Vol 64 (7) ◽  
pp. 469-473 ◽  
Author(s):  
Nemanja Mirkovic

Background/Aim. Elastic modulus of metal-ceramic systems determines their flexural strength and prevents damages on ceramics during mastication. Recycling of basic alloys is often a clinical practice, despite the possible effects on the quality of the future metal-ceramic dentures. This research was done to establish recasting effects of nickel-chromium and cobalt-chromium alloys on the elastic modulus of metalceramic systems in making fixed partial dentures. Methods. The research was performed as an experimental study. Six metal-ceramic samples of nickel-chromium alloy (Wiron 99) and cobalt-chromium alloy (Wirobond C) were made. Alloy residues were recycled through twelve casting generations with the addition of 50% of new alloy on the occasion of every recasting. Three- point bending test was used to determine elastic modulus, recommended by the standard ISO 9693:1999. Fracture load for damaging ceramic layer was recorded on the universal testing machine (Zwick, type 1464), with the speed of 0,05 mm/min. Results. The results of this research revealed significant differences between elasticity modules of metal-ceramic samples in every examined recycle generation. Recasting had negative effect on the elastic modulus of the examined alloys. This research showed the slight linear reduction of elastic modulus up to the 6th generation of recycling. After the 6th recycling there was a sudden fall of elastic modulus. Conclusion. Recasting of nickelchromium and cobalt-chromium alloys is not recommended because of the reduced elastic modulus of these alloys. Instead of reusing previously recasted alloys, the alloy residues should be returned to the manufacturer. .


2014 ◽  
Vol 15 (6) ◽  
pp. 688-692 ◽  
Author(s):  
Sukumaran Anil ◽  
Farouk Ahmed Hussein ◽  
Mohammed Ibrahim Hashem ◽  
Elna P Chalisserry

ABSTRACT Objective The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Subjects and methods Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. Results No statistically significant difference was found in bond strengths’ values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. Conclusion The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength. How to cite this article Hussein FA, Hashem MI, Chalisserry EP, Anil S. The Impact of Chlorhexidine Mouth Rinse on the Bond Strength of Polycarbonate Orthodontic Brackets. J Contemp Dent Pract 2014;15(6):688-692.


2016 ◽  
Vol 29 (1) ◽  
pp. 87-93 ◽  
Author(s):  
Li Zhou ◽  
Yuetong Qian ◽  
Kang Gan ◽  
Hong Liu ◽  
Xiuju Liu ◽  
...  

This study was designed to evaluate the shear bond strength of an adhesive/composite system subjected to different pretreated polyetheretherketone (PEEK) surfaces using different thermocycling conditioning methods. A total of 128 specimens were equally divided into four main groups ( n = 32/group): control (no pretreatment), air abrasion, argon plasma pretreatment, and femtosecond laser groups. The surface topographies and surface roughness were observed by atomic force microscopy after different pretreatments. The specimens were bonded with SE Bond/Clearfil AP-X™. All bonded specimens were stored in distilled water at 37°C for 24 h. Afterward, each group was divided into three subgroups ( n = 8/group) as follows: (a) stored in water for 56 h (37°C); (b) thermal aging for 5000 cycles (5°C/55°C); and (c) thermal aging for 10,000 cycles (5°C/55°C). The shear bond strengths were measured. Air abrasion, argon plasma pretreatment, and femtosecond laser significantly strengthened the bond of SE Bond/Clearfil AP-X™ to PEEK composite compared with that without additional pretreatment. In the same surface pretreatment, the shear bond strengths of specimens conditioned using water storage were higher than that using thermocycles (TCs). Additionally, the specimens with 5000 TC showed significantly higher shear bond strength than that with 10000 TC.


2013 ◽  
Vol 38 (2) ◽  
pp. 186-196 ◽  
Author(s):  
Camila Sabatini ◽  
Manthan Patel ◽  
Eric D'Silva

SUMMARY Objective To evaluate the shear bond strength (SBS) of three self-adhesive resin cements and a resin-modified glass ionomer cement (RMGIC) to different prosthodontic substrates. Materials and Methods The substrates base metal, noble metal, zirconia, ceramic, and resin composite were used for bonding with different cements (n=12). Specimens were placed in a bonding jig, which was filled with one of four cements (RelyX Unicem, Multilink Automix, Maxcem Elite, and FujiCEM Automix). Both light-polymerizing (LP) and self-polymerizing (SP) setting reactions were tested. Shear bond strength was measured at 15 minutes and 24 hours in a testing device at a test speed of 1 mm/min and expressed in MPa. A Student t-test and a one-way analysis of variance (ANOVA) were used to evaluate differences between setting reactions, between testing times, and among cements irrespective of other factors. Generalized linear regression model and Tukey tests were used for multifactorial analysis. Results Significantly higher mean SBS were demonstrated for LP mode relative to SP mode (p&lt;0.001) and for 24 hours relative to 15 minutes (p&lt;0.001). Multifactorial analysis revealed that all factors (cement, substrate, and setting reaction) and all their interactions had a significant effect on the bond strength (p&lt;0.001). Resin showed significantly higher SBS than other substrates when bonded to RelyX Unicem and Multilink Automix in LP mode (p&lt;0.05). Overall, FujiCEM demonstrated significantly lower SBS than the three self-adhesive resin cements (p&lt;0.05). Conclusions Overall, higher bond strengths were demonstrated for LP relative to SP mode, 24 hours relative to 15 minutes and self-adhesive resin cements compared to the RMGICs. Bond strengths also varied depending on the substrate, indicating that selection of luting cement should be partially dictated by the substrate and the setting reaction.


2009 ◽  
Vol 79 (3) ◽  
pp. 564-570 ◽  
Author(s):  
Toshiya Endo ◽  
Rieko Ozoe ◽  
Koichi Shinkai ◽  
Makiko Aoyagi ◽  
Hiroomi Kurokawa ◽  
...  

Abstract Objective: To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. Materials and Methods: A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. Results: At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. Conclusions: The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.


1993 ◽  
Vol 20 (3) ◽  
pp. 225-229 ◽  
Author(s):  
W. H. Sam ◽  
S. Y. Chao ◽  
K. H. Chung

The shear bond strength of two adhesives (Concise® and Dyna-Plus® bonding system) with one type of ceramic bracket was determined in this study. There were statistically significant differences between the bond strengths, with Concisereg; recording higher levels than Dyna-Plus®. Failure sites of Dyna-Plus® were revealed at the enamel/resin, resin/resin, and resin/bracket interfaces; that of the Concise® was mainly at the resin/bracket interface.


Sign in / Sign up

Export Citation Format