scholarly journals The diagnostic accuracy of serological tests for Lyme borreliosis in Europe: a systematic review and meta-analysis

2016 ◽  
Vol 16 (1) ◽  
Author(s):  
M. M. G. Leeflang ◽  
C. W. Ang ◽  
J. Berkhout ◽  
H. A. Bijlmer ◽  
W. Van Bortel ◽  
...  
BMJ ◽  
2020 ◽  
pp. m2516 ◽  
Author(s):  
Mayara Lisboa Bastos ◽  
Gamuchirai Tavaziva ◽  
Syed Kunal Abidi ◽  
Jonathon R Campbell ◽  
Louis-Patrick Haraoui ◽  
...  

AbstractObjectiveTo determine the diagnostic accuracy of serological tests for coronavirus disease-2019 (covid-19).DesignSystematic review and meta-analysis.Data sourcesMedline, bioRxiv, and medRxiv from 1 January to 30 April 2020, using subject headings or subheadings combined with text words for the concepts of covid-19 and serological tests for covid-19.Eligibility criteria and data analysisEligible studies measured sensitivity or specificity, or both of a covid-19 serological test compared with a reference standard of viral culture or reverse transcriptase polymerase chain reaction. Studies were excluded with fewer than five participants or samples. Risk of bias was assessed using quality assessment of diagnostic accuracy studies 2 (QUADAS-2). Pooled sensitivity and specificity were estimated using random effects bivariate meta-analyses.Main outcome measuresThe primary outcome was overall sensitivity and specificity, stratified by method of serological testing (enzyme linked immunosorbent assays (ELISAs), lateral flow immunoassays (LFIAs), or chemiluminescent immunoassays (CLIAs)) and immunoglobulin class (IgG, IgM, or both). Secondary outcomes were stratum specific sensitivity and specificity within subgroups defined by study or participant characteristics, including time since symptom onset.Results5016 references were identified and 40 studies included. 49 risk of bias assessments were carried out (one for each population and method evaluated). High risk of patient selection bias was found in 98% (48/49) of assessments and high or unclear risk of bias from performance or interpretation of the serological test in 73% (36/49). Only 10% (4/40) of studies included outpatients. Only two studies evaluated tests at the point of care. For each method of testing, pooled sensitivity and specificity were not associated with the immunoglobulin class measured. The pooled sensitivity of ELISAs measuring IgG or IgM was 84.3% (95% confidence interval 75.6% to 90.9%), of LFIAs was 66.0% (49.3% to 79.3%), and of CLIAs was 97.8% (46.2% to 100%). In all analyses, pooled sensitivity was lower for LFIAs, the potential point-of-care method. Pooled specificities ranged from 96.6% to 99.7%. Of the samples used for estimating specificity, 83% (10 465/12 547) were from populations tested before the epidemic or not suspected of having covid-19. Among LFIAs, pooled sensitivity of commercial kits (65.0%, 49.0% to 78.2%) was lower than that of non-commercial tests (88.2%, 83.6% to 91.3%). Heterogeneity was seen in all analyses. Sensitivity was higher at least three weeks after symptom onset (ranging from 69.9% to 98.9%) compared with within the first week (from 13.4% to 50.3%).ConclusionHigher quality clinical studies assessing the diagnostic accuracy of serological tests for covid-19 are urgently needed. Currently, available evidence does not support the continued use of existing point-of-care serological tests.Study registrationPROSPERO CRD42020179452.


2021 ◽  
Vol 3 (4) ◽  
pp. 283-301
Author(s):  
Carmel Reina R. Chua ◽  
Esther Delle E. De los Santos ◽  
Karla Veronica H. Escasa ◽  
Richmond Louis G. Estolas ◽  
Junnealyn Feliciano ◽  
...  

Introduction: Coronavirus Disease (COVID-19) is a highly infectious disease caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) which has infected many people all over the world. One of the best ways to lessen its spread is through early detection and diagnosis. Various serological tests are now being used as a surveillance tool in the detection of antibodies as a response to SARS-CoV-2. The aim of this study is to evaluate the diagnostic accuracy and performance of the available COVID-19 antibody tests authorized by the Food and Drug Administration (FDA) Philippines that make use of Enzyme-Linked Immunosorbent Assay (ELISA), Chemiluminescence Immunoassay (CLIA) and Lateral Flow Immunoassay (LFIA). Method: Complete published journal articles relevant to the diagnostic accuracy of the three antibody tests were collected using trusted medical journal search engines. The quality of journals was assessed using QUADAS-2 to determine the risk of bias and assess the applicability judgments of diagnostic accuracy studies. Forest plots were used to summarize the performance of LFIA, ELISA and CLIA according to their specificity and sensitivity in detecting various antibodies. Pooled sensitivity and specificity were also done using bivariate random-effects models with its log-likelihood, a corresponding chi-square test statistic, and area under the summary Receiver-Operating Characteristic curve to see the potential heterogeneity in the data and to assess the diagnostic accuracy of the COVID-19 antibody tests. Results: Bivariate random-effects model and areas under the sROC curve were used to evaluate the diagnostic accuracy of COVID-19 antibody tests. The pooled sensitivity in detecting IgG based on CLIA, ELISA, and LFIA were 81.7%, 58.7%, and 74.3% respectively, with an overall of 72.0%. For IgM detection, LFIA has a higher pooled sensitivity of 69.6% than CLIA with 61.0%. Overall, the pooled sensitivity is 68.5%. In IgA detection, only ELISA based test was included with a pooled sensitivity of 84.8%. Lastly, pooled sensitivities for combined antibodies based on ELISA and LFIA were 89.0% and 81.6% respectively, with an overall of 82.5%. On the other hand, all tests excluding ELISA-IgA displayed high pooled specificities with a range of 94.0% to 100.0%. Diagnostic accuracies of the test in detecting IgG, IgM, and combined antibodies were found out to be almost perfect based on the computed area under the sROC with values of 0.973, 0.953, and 0.966, respectively. Conclusion: In this systematic review and meta-analysis, existing evidence on the diagnostic accuracy of antibody tests for COVID-19 were found to be characterized by high risks of bias, consistency in the heterogeneity of sensitivities, and consistency in the homogeneity of high specificities except in IgA detection using ELISA. The bivariate random-effects models showed that there are no significant differences in terms of sensitivity among CLIA, ELISA and LFIA in detecting IgG, IgM, and combined antibodies at a 95% confidence interval. Nonetheless, CLIA, ELISA and LFIA were found to have excellent diagnostic accuracies in the detection of IgG, IgM and combined antibodies as reflected by their AUC values. Doi: 10.28991/SciMedJ-2021-0304-1 Full Text: PDF


BMJ Open ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. e038449
Author(s):  
Lisa Helen Telford ◽  
Leila Hussein Abdullahi ◽  
Eleanor Atieno Ochodo ◽  
Liesl Joanna Zuhlke ◽  
Mark Emmanuel Engel

ObjectiveTo summarise the accuracy of handheld echocardiography (HAND) which, if shown to be sufficiently similar to that of standard echocardiography (STAND), could usher in a new age of rheumatic heart disease (RHD) screening in endemic areas.DesignSystematic review and meta-analysis.Data sourcesPubMed, Scopus, EBSCOHost and ISI Web of Science were initially searched on 27 September 2017 and again on 3 March 2020 for studies published from 2012 onwards.Eligibility criteriaStudies assessing the accuracy of HAND compared with STAND when performed by an experienced cardiologist in conjunction with the 2012 World Heart Federation criteria among populations of children and adolescents living in endemic areas were included.Data extraction and synthesisTwo reviewers independently extracted data and assessed the methodological quality of included studies against review-specific Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 criteria. A meta-analysis using the hierarchical summary receiver operating characteristic model was conducted to produce summary results of sensitivity and specificity. Forest plots and scatter plots in receiver operating characteristic space in combination with subgroup analyses were used to investigate heterogeneity. Publication bias was not investigated.ResultsSix studies (N=4208) were included in the analysis. For any RHD detection, the pooled results from six studies were as follows: sensitivity: 81.56% (95% CI 76.52% to 86.61%) and specificity: 89.75% (84.48% to 95.01%). Meta-analytical results from five of the six included studies were as follows: sensitivity: 91.06% (80.46% to 100%) and specificity: 91.96% (85.57% to 98.36%) for the detection of definite RHD only and sensitivity: 62.01% (31.80% to 92.22%) and specificity: 82.33% (65.15% to 99.52%) for the detection of borderline RHD only.ConclusionsHAND displayed good accuracy for detecting definite RHD only and modest accuracy for detecting any RHD but demonstrated poor accuracy for the detection of borderline RHD alone. Findings from this review provide some evidence for the potential of HAND to increase access to echocardiographic screening for RHD in resource-limited and remote settings; however, further research into feasibility and cost-effectiveness of wide-scale screening is still needed.PROSPERO registration numberCRD42016051261.