scholarly journals Reliability and minimal detectable change of the ‘Imperial Spine’ marker set for the evaluation of spinal and lower limb kinematics in adults

2020 ◽  
Vol 13 (1) ◽  
Author(s):  
J. A. Deane ◽  
E. Papi ◽  
A. T. M. Phillips ◽  
A. H. McGregor

Abstract Objectives As a step towards the comprehensive evaluation of movement in patients with low back pain, the aim of this study is to design a marker set (three rigid segment spine, pelvic and lower limb model) and evaluate the reliability and minimal detectable change (MDC) of this marker set in healthy adults during gait and sit to stand (STS) tasks using three dimensional motion capture. Results The ‘Imperial Spine’ marker set was used to assess relative peak angles during gait and STS tasks using the minimum recommended sample size (n = 10) for reliability studies with minimum Intraclass Correlation Coefficient (ICC) of 0.70, optimum ICC 0.90 and 9 trials replicated per subject per task. Intra- and inter-tester reliability between an experienced and inexperienced user was examined. ICC, mean, standard error (SEM), Bland Altman 95% limits of agreement (LOA) and MDC were computed. ICC values demonstrated excellent intra- and inter-tester reliability in both tasks, particularly in the sagittal plane (majority ICCs > 0.80). SEM measurements were lower in gait (0.8–5.5°) than STS tasks (1°-12.6°) as were MDC values. LOA demonstrated good agreement. The ‘Imperial Spine’ marker set is reliable for use in healthy adults during functional tasks. Future evaluation in patients is required.

2008 ◽  
Vol 88 (5) ◽  
pp. 652-663 ◽  
Author(s):  
Joanne M Wagner ◽  
Jennifer A Rhodes ◽  
Carolynn Patten

Background and Purpose Three-dimensional kinematic analysis of reaching has emerged as an evaluative measure of upper-extremity motor performance in people after stroke. However, the psychometric properties supporting the use of kinematic data for evaluating longitudinal change in motor performance have not been established. The objective of this study was to determine, in a test-retest reliability manner, the reproducibility and minimal detectable change for reaching kinematics in people after stroke. Subjects and Methods Fourteen participants with hemiparesis after stroke performed forward reaching tasks on 2 occasions 37.3 (SD=9.8) days apart. At each session, participants performed 4 forward reaching tasks produced by the combination of 2 target heights (low and high [109 and 153 cm from the floor, respectively]) and 2 instructed movement speeds (self-selected and as fast as possible). Two analytical methods were used to calculate kinematic parameters. Results Relative reliability (intraclass correlation coefficient) ranged from .04 to .99, and absolute reliability (standard error of measurement) ranged from 2.7% to 76.8%, depending on the kinematic variable, the demands of the motor task (target height and movement speed), and the analytical method. Bland-Altman analysis, a statistical method used to assess the repeatability of a method, revealed few systematic errors between sessions. The minimal detectable change ranged from 7.4% to 98.9%. Discussion and Conclusion Depending on the demands of the motor task and the analytical method, most kinematic outcome measures (such as peak hand velocity, endpoint error, reach extent, maximum shoulder flexion range of motion, and minimum elbow extension range of motion) are reliable measures of motor performance in people after stroke. However, because of the magnitude of within-subject measurement error, some variables (such as peak hand velocity, time to peak hand velocity, and movement time) must change considerably (>50%) to indicate a real change in individual participants. The results of our reliability analysis, which are based on our cohort of participants with hemiparesis after stroke and our specific paradigm, may not be generalizable to different subpopulations of people with hemiparesis after stroke or to the myriad movement tasks and kinematic variables used for the assessment of reaching performance in people after stroke.


2017 ◽  
Vol 4 ◽  
pp. 205566831772999 ◽  
Author(s):  
Pia Wedege ◽  
Kathrin Steffen ◽  
Vegard Strøm ◽  
Arve Isak Opheim

Objectives Three-dimensional gait analysis has been recommended as part of standardized gait assessment in people with spinal cord injury. The aim was to investigate inter- and intra-session reliabilities of gait kinematics in people with spinal cord injury. Methods Fifteen adults with spinal cord injury performed two test sessions on separate days. Six infrared cameras, 16 reflective markers and the Plug-in gait model were used. For each subject, five gait trials from both sessions were included. The Gait Profile Score and the Gait Variable Score were used as kinematic outcome measures. Reliability was assessed with intraclass correlation coefficient, standard error of measurement, minimal detectable change, and Bland–Altman plots. Results Inter-session intraclass correlation coefficient for all variables was >0.82 and standard error of measurement <1.8°, except for hip rotation. Intra-session reliability was found to be high (≥0.78) and slightly better than that for inter-session. Minimal detectable change for all variables was <4.7°, except for hip rotation. Conclusions The high inter- and intra-session reliabilities indicate small intrinsic variation of gait. Thus, three-dimensional gait analysis seems to be a reliable tool to evaluate kinematic gait in adults with spinal cord injury, but caution is warranted especially for hip rotation evaluation.


2021 ◽  
Author(s):  
A Wallin ◽  
M Kierkegaard ◽  
E Franzén ◽  
S Johansson

Abstract Objective The mini-BESTest is a balance measure for assessment of the underlying physiological systems for balance control in adults. Evaluations of test–retest reliability of the mini-BESTest in larger samples of people with multiple sclerosis (MS) are lacking. The purpose of this study was to investigate test–retest reliability of the mini-BESTest total and section sum scores and individual items in people with mild to moderate overall MS disability. Methods This study used a test–retest design in a movement laboratory setting. Fifty-four people with mild to moderate overall MS disability according to the Expanded Disability Status scale (EDSS) were included, with 28 in the mild subgroup (EDSS 2.0–3.5) and 26 in the moderate subgroup (EDSS 4.0–5.5). Test–retest reliability of the mini-BESTest was evaluated by repeated measurements taken 1 week apart. Reliability and measurement error were analyzed. Results Test–retest reliability for the total scores were considered good to excellent, with intraclass correlation coefficients of .88 for the whole sample, .83 for the mild MS subgroup, and .80 for the moderate MS subgroup. Measurement errors were small, with standard error of measurement and minimal detectable change of 1.3 and 3.5, respectively, in mild MS, and 1.7 and 4.7, respectively, in moderate MS. The limits of agreement were − 3.4 and 4.6. Test–retest reliability for the section scores were fair to good or excellent; weighted kappa values ranged from .62 to .83. All items but 1 showed fair to good or excellent test–retest reliability, and percentage agreement ranged from 61% to 100%. Conclusions The mini-BESTest demonstrated good to excellent test–retest reliability and small measurement errors and is recommended for use in people with mild to moderate MS. Impact Knowledge of limits of agreement and minimal detectable change contribute to interpretability of the mini-BESTest total score. The findings of this study enhance the clinical usefulness of the test for evaluation of balance control and for designing individually customized balance training with high precision and accuracy in people with MS.


2019 ◽  
Vol 48 (Supplement_4) ◽  
pp. iv18-iv27 ◽  
Author(s):  
Kitima Rongsawad ◽  
Laddawon Worawan ◽  
Karnsiree Jirarojprapa ◽  
Sararat Kaewkham ◽  
Sarawut Khattiwong

Abstract Introduction Static postural stability is the ability to maintain the posture with minimum sway. Increasing postural sway during standing in different sensory conditions is associated with aging due to decline in sensory and motor functions. Sway area measured by using sway meter is usually simple method for assessing postural stability in elderly subjects. Like many biological measurements, sway area has an intrinsic variability that affects their test-retest reliability and responsiveness of postural stability assessment. The minimal detectable change (MDC) is ability to detect smallest change beyond measurement error that reflects a reliable change. Therefore, the MDC value could provide information of clinical relevance on postural stability. The aims of this study were to determine test-retest reliability and MDC of sway area obtained from sway meter in elderly subjects. Methods Twelve healthy elderly subjects aged 60 years and above were participated in this study. The test and retest repeatability of postural sway measurements were performed twice with a 1-hour interval. For each subject was assess postural sway using Lord’s sway meter during standing on 4 sensory conditions for 30 seconds of each condition. The test-retest reliability of sway area was calculated using intraclass correlation coefficient. The MDC for each sway area was calculated to quantify clinical relevance. Results The test-retest reliability of sway area revealed good to excellent reliability ranged from 0.85 to 0.94. Standard error of measurement (SEM) and MDC ranged from 75 to 205 mm2 and 209 to 568 mm2, respectively. Discussion and Conclusion Our findings reveal that sway area in different sensory conditions could be used in assessment of postural stability in elderly subjects. SEM and MDC of sway area increased when subjects were asked to close their eyes and on foam surface. The sway meter is a reliable tool for assessing postural stability in clinical setting.


2018 ◽  
Vol 21 (02) ◽  
pp. 1850009
Author(s):  
Yohei Kanno ◽  
Hajime Toda ◽  
Tsutomu Horiuchi ◽  
Masaki Katayose

Objective: The aim of this study was to establish intra-rater and inter-rater reliability of a measurement method for the pathway of the supraspinatus intramuscular tendon by 3.0 tesla MRI images. Methods: The scapula and intramuscular tendon extraction DICOM data was made to extract only a scapula domain and intramuscular tendon domain. The shear force angle anterior posterior (SFA-AP) was measured as the pathway of supraspinatus intramuscular tendon with respect to the glenoid plane on three-dimensional (3D) models of the bone and intramuscular tendon. SFA-AP of supraspinatus was measured on 3D models of the bone and intramuscular tendon. The mean and standard deviation of SFA-AP of supraspinatus was calculated. Intra-rater reliability and inter-rater reliability were evaluated by the intraclass correlation coefficient (ICC), the standard error of the mean (SEM) and the minimal detectable change (MDC). Inter-rater reliability was evaluated by three raters. Results: As for intra-rater reliability, SFA-AP of supraspinatus measured averaged [Formula: see text], with ICC (1,1) of 0.978, with ICC (1,3) of 0.993, with SEM of 0.53, with MDC of 1.46[Formula: see text]. As for inter-rater reliability, SFA-AP of supraspinatus measured averaged [Formula: see text] (rater1), SFA-AP measured averaged [Formula: see text] (rater2), SFA-AP measured averaged [Formula: see text] (rater3), with ICC (2,1) of 0.896, with ICC (2,3) of 0.963, with SEM of 1.11, with MDC of 3.09[Formula: see text]. Conclusions: 3D models of the bone and intramuscular tendon were evaluated as intra-rater and inter-rater reliabilities. SFA-AP of supraspinatus is guaranteed by one measurement.


2020 ◽  
Vol 47 (4) ◽  
pp. 479-486
Author(s):  
Yuki Kondo ◽  
Kyota Bando ◽  
Yosuke Ariake ◽  
Wakana Katsuta ◽  
Kyoko Todoroki ◽  
...  

BACKGROUND: The reliability of the evaluation of the Balance Evaluation Systems Test (BESTest) and its two abbreviated versions are confirmed for balance characteristics and reliability. However, they are not utilized in cases of spinocerebellar ataxia (SCA). OBJECTIVE: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BESTest and its abbreviated versions in persons with mild to moderate spinocerebellar ataxia. METHODS: The BESTest was performed in 20 persons with SCA at baseline and one month later. The scores of the abbreviated version of the BESTest were determined from the BESTest scores. The interclass correlation coefficient (1,1) was used as a measure of relative reliability. Furthermore, we calculated the MDC in the BESTest and its abbreviated versions. RESULTS: The intraclass correlation coefficients (1,1) and MDC at 95% confidence intervals were 0.92, 8.7(8.1%), 0.91, 4.1(14.5%), and 0.81, 5.2(21.6%) for the Balance, Mini-Balance, and Brief-Balance Evaluation Systems Tests, respectively. CONCLUSIONS: The BESTest and its abbreviated versions had high test-retest reliability. The MDC values of the BESTest could enable clinicians and researchers to interpret changes in the balance of patients with SCA more precisely.


2020 ◽  
Author(s):  
Azadeh Nasseri ◽  
David G Lloyd ◽  
Adam L Bryant ◽  
Jonathon Headrick ◽  
Timothy Sayer ◽  
...  

AbstractThis study determined anterior cruciate ligament (ACL) force and its contributors during a standardized drop-land-lateral jump task using a validated computational model. Healthy females (n=24) who were recreationally active performed drop-land-lateral jump and straight run tasks. Three-dimensional whole-body kinematics, ground reaction forces, and muscle activation patterns from eight lower limb muscles were collected concurrently during both tasks, but only the jump was analyzed computationally, with the run included for model calibration. External biomechanics, muscle-tendon unit kinematics, and muscle activation patterns were used to model lower limb muscle and ACL forces. Peak ACL force (2.3±0.5 BW) was observed at 13% of the stance phase during the drop-land-lateral jump task. The ACL force was primarily developed through the sagittal plane, and muscle was the dominant source of ACL loading. The gastrocnemii and quadriceps were main ACL antagonists (i.e., loaders), while hamstrings were the main ACL agonists (i.e., supporters).


2020 ◽  
Vol 14 (2) ◽  
pp. 169-176
Author(s):  
Catarina Marques ◽  
Emma Granström ◽  
Anna MacDowall ◽  
Nuno Canto Moreira ◽  
Martin Skeppholm ◽  
...  

Study Design: This study is a post hoc analysis of a multicenter prospective randomized controlled trial which compared artificial disc replacement and anterior cervical discectomy and fusion.Purpose: Useful radiographic parameters for assessing cervical alignment include the Cobb angles, T1 slope (T1S), occipitocervical inclination (OCI), K-line tilt (KLT), and cervical sagittal vertical axis (cSVA). This study aimed to determine measurement accuracy and reliability for these parameters.Overview of Literature: Various authors have assessed repeatability by comparing different methods of measurement, but knowledge of measurement error and minimal detectable change is scarce.Methods: We evaluated 758 lateral cervical radiographs. One medical student and one spine surgeon (i.e., measured ×2 within 4 weeks) independently measured the parameters obtaining 5,850 values. Standard error of measurement (SEm) and minimum detectable change (MDC) were calculated for each parameter. The accuracy and reliability of the Cobb angle measurements were calculated for the different types of angles: cervical lordosis, prosthesis angle, segmental angle with two bone surfaces (SABB), and segmental angle with one bone and one metal surface. Reliability was determined with intraclass correlation coefficient (ICC).Results: SEm was 1.8° and MDC was 5.0° for the Cobb angle, with an intraobserver/interobserver ICC of 0.958/0.886. All the different subtypes of Cobb angles had an ICC higher than 0.950, except SABB (intraobserver/interobserver ICC of 0.922/0.716). The most accurate and reliable measurement was for KLT.Conclusions: This study provides normative data on SEm and MDC for Cobb angles, T1S, KLT, OCI, and cSVA in cervical lateral radiographs. Reliability was excellent for all parameters except SABB (e.g., good).


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Haeun Yum ◽  
Hyang Kim ◽  
Taeyong Lee ◽  
Moon Seok Park ◽  
Seung Yeol Lee

Abstract Background Stationary cycling is commonly used for postoperative rehabilitation of physical disabilities; however, few studies have focused on the three-dimensional (3D) kinematics of rehabilitation. This study aimed to elucidate the three-dimensional lower limb kinematics of people with healthy musculoskeletal function and the effect of sex and age on kinematics using a controlled bicycle configuration. Methods Thirty-one healthy adults participated in the study. The position of the stationary cycle was standardized using the LeMond method by setting the saddle height to 85.5% of the participant’s inseam. The participants maintained a pedaling rate of 10–12 km/h, and the average value of three successive cycles of the right leg was used for analysis. The pelvis, hip, knee, and ankle joint motions during cycling were evaluated in the sagittal, coronal, and transverse planes. Kinematic data were normalized to 0–100% of the cycling cycle. The Kolmogorov-Smirnov test, Mann-Whitney U test, Kruskal-Wallis test, and k-fold cross-validation were used to analyze the data. Results In the sagittal plane, the cycling ranges of motion (ROMs) were 1.6° (pelvis), 43.9° (hip), 75.2° (knee), and 26.9° (ankle). The coronal plane movement was observed in all joints, and the specific ROMs were 6.6° (knee) and 5.8° (ankle). There was significant internal and external rotation of the hip (ROM: 11.6°), knee (ROM: 6.6°), and ankle (ROM: 10.3°) during cycling. There was no difference in kinematic data of the pelvis, hip, knee, and ankle between the sexes (p = 0.12 to 0.95) and between different age groups (p = 0.11 to 0.96) in all anatomical planes. Conclusions The kinematic results support the view that cycling is highly beneficial for comprehensive musculoskeletal rehabilitation. These results might help clinicians set a target of recovery ROM based on healthy and non-elite individuals and issue suitable guidelines to patients.