scholarly journals Immunoassay-based approaches for development of screening of chlorpyrifos

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Noor Saba Khan ◽  
Dibyabhaba Pradhan ◽  
Saumya Choudhary ◽  
Pallavi Saxena ◽  
Nitesh Kumar Poddar ◽  
...  

AbstractChlorpyrifos (CPF) is an extensively used organophosphate pesticide for crop protection. However, there are concerns of it contaminating the environment and human health with estimated three lakh deaths annually. Detection of CPF in blood samples holds significance to avoid severe health outcomes due to continuous exposure. The most common techniques for CPF detection are Gas chromatography (GC) and high-performance liquid chromatography (HPLC). However, these techniques might not be feasible at the community healthcare level due to high-cost instrumentation, time-consuming sample preparation protocol and skilled analysts. Therefore, rapid, effective and economical methods such as immunoassay would be imperative for CPF detection in biological samples. The vital step in immunoassay development is the design of a potent immunogen from non-immunogenic molecules. The molecular modelling protocol could assist in redesigning known CPF linkers and inserting them at different substitutable positions of CPF to get distinctive CPF derivatives. Molecular docking and binding free energy analysis can be used to identify the CPF derivatives having a better binding affinity with carrier protein compared to CPF. The top-ranked CPF derivatives based on docking score and binding energy could be ideal for synthesis and immunogen development. The present review will comprehend technological trends in immunoassay kits for detecting chlorpyrifos from biological samples.

2011 ◽  
Vol 17 (11) ◽  
pp. 2805-2816 ◽  
Author(s):  
Mathew Varghese Koonammackal ◽  
Unnikrishnan Viswambharan Nair Nellipparambil ◽  
Chellappanpillai Sudarsanakumar

2018 ◽  
Vol 20 (suppl_6) ◽  
pp. vi67-vi67
Author(s):  
Peter Pan ◽  
Alireza Tafazzol ◽  
Xianwei Zhang ◽  
Yong Duan

2021 ◽  
Vol 99 (Supplement_1) ◽  
pp. 206-207
Author(s):  
Michael O Wellington ◽  
Michael A Bosompem ◽  
Veronika Nagl ◽  
Daniel A Columbus

Abstract Due to difficulties in obtaining consistent and/or reliable measures of deoxynivalenol (DON) in complete swine diets, we investigated whether measuring DON in biological samples could be used as an indicator of DON ingestion in pigs. In this study, graded levels of DON (1, 3, or 5 ppm) were fed to grower-finisher pigs for a period of 77-d. On d 35 and 77 of the study, urine samples were quantitatively collected over a 24-h period and blood samples were collected between 3 – 4 h after the morning meal on each of those days for serum DON analysis. For direct quantification of DON in urine, high-performance liquid chromatography with tandem mass spectrometry was performed. For serum samples, indirect quantification of DON was performed via enzymatic hydrolysis. We observed that DON content in urine increased linearly as intake of DON increased (Fig.1A; P < 0.05). Analysis of DON in serum follow a similar trend, where serum DON content was increased as DON intake increased (Fig.1B; P < 0.05). An average of 30% of DON ingested was recovered as DON in urine over a 24-h period. In summary, there was a linear relationship between DON intake and DON content in both urine and blood serum, therefore, analyzing DON concentration in serum and urine could be used as a tool to estimate for DON exposure in pigs under controlled conditions.


2019 ◽  
Vol 116 (3) ◽  
pp. 477a
Author(s):  
Peter C. Pan ◽  
Alireza Tafazzol ◽  
Xianwei Zhang ◽  
Yong Duan

Sign in / Sign up

Export Citation Format

Share Document