scholarly journals Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study

2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Mehmet Hakan Kurt ◽  
Nilsun Bağış ◽  
Cengiz Evli ◽  
Cemal Atakan ◽  
Kaan Orhan

Abstract Background To examine the influence of voxel sizes to detect of peri-implant fenestration defects on cone beam computed tomography (CBCT) images. Materials and methods This study performed with three sheep heads both maxilla and mandible and two types of dental implant type 1 zirconium implant (Zr40) (n = 6) and type 2 titanium implant (Ti22) (n = 10). A total of 14 peri-implant fenestrations (8 buccal surfaces, 6 palatal/lingual surface) were created while 18 surfaces (8 buccal, 10 palatal/lingual) were free of fenestrations. Three observers have evaluated the images of fenestration at each site. Images obtained with 0.75 mm3, 0.100 mm3, 0.150 mm3, 0.200 mm3, and 0.400 mm3 voxel sizes. For intra- and inter-observer agreements for each voxel size, Kappa coefficients were calculated. Results Intra- and inter-observer kappa values were the highest for 0.150 mm3, and the lowest in 0.75 mm3 and 0.400 mm3 voxel sizes for all types of implants. The highest area under the curve (AUC) values were found higher for the scan mode of 0.150 mm3, whereas lower AUC values were found for the voxel size for 0.400 mm3. Titanium implants had higher AUC values than zirconium with the statistical significance for all voxel sizes (p ≤ 0.05). Conclusion A voxel size of 0.150 mm3 can be used to detect peri-implant fenestration bone defects. CBCT is the most reliable diagnostic tool for peri-implant fenestration bone defects.

2021 ◽  
Vol 15 (1) ◽  
pp. 57-63
Author(s):  
Lauren Bohner ◽  
Pedro Tortamano ◽  
Felix Gremse ◽  
Israel Chilvarquer ◽  
Johannes Kleinheinz ◽  
...  

Background: Cone-Beam Computed Tomography (CBCT) with high-resolution parameters may provide an acceptable resolution for bone assessment. Objectives: The purpose of this study is to assess trabecular bone using two cone-beam computed tomography (CBCT) devices with high-resolution parameters in comparison to micro-computed tomography (µCT). Methods: Bone samples (n=8) were acquired from dry mandibles and scanned by two CBCT devices: 1) VV (Veraview R100, Morita; FOV 4x4, 75kV, 9mA, voxel size 0.125µm); and PR (Prexion 3D, Prexion; FOV 5x5, 90kV, 4mA, 37s, voxel size 108µm). Gold-standard images were acquired using µCT (SkyScan 1272; Bruker; 80kV, 125mA, voxel size 16µm). Morphometric parameters (BvTv- Bone Volume Fraction, BsBv- Trabecular specific surface, TbTh- Trabecular thickness and TbSp- Trabecular separation) were measured. Statistical analysis was performed within ANOVA, Spearman Correlation test and Bland-Altmann plots with a statistical significance level at p=0.05. Results: CBCT devices showed similar BvTv values in comparison to µCT. No statistical difference was found for BvTv parameters assessed by CBCT devices and µCT. BsBv values were underestimated by CBCT devices (p<0.01), whereas TbTh and TbSp values were overestimated by them (p<0.01). Positive correlations were found between VV and µCT measurements for BvTv (r2= 0.65, p=0.00), such as between PR and µCT measurements for TbSp (r2= 0.50, p=0.04). For BsBv measurements, PR was negatively correlated with µCT (r2= -0.643, p=0.01). Conclusion: The evaluated CBCT device was able to assess trabecular bone. However, bone parameters were under or overestimated in comparison to µCT.


2021 ◽  
Vol 41 (6) ◽  
pp. e223-e231
Author(s):  
Angel Insua ◽  
Yolanda Gañán ◽  
Yolanda Macías ◽  
Juan Garcia ◽  
Mia Rakic ◽  
...  

2021 ◽  
Author(s):  
Masoumeh Eftekhar ◽  
Hanieh Kaviani ◽  
Nina Rouzmeh ◽  
Aitin Torabinia ◽  
Alireza Akbarzadeh Baghban

2018 ◽  
Vol 44 (12) ◽  
pp. 1862-1866 ◽  
Author(s):  
Elen de Souza Tolentino ◽  
Pablo Andrés Amoroso-Silva ◽  
Murilo Priori Alcalde ◽  
Heitor Marques Honório ◽  
Lilian Cristina Vessoni Iwaki ◽  
...  

2020 ◽  
Vol 40 (2) ◽  
pp. e65-e72
Author(s):  
Spyridon Vassilopoulos ◽  
Yiorgos Bobetsis ◽  
Michalis Mastoris ◽  
Eudoxie Pepelassi ◽  
Keti Nikopoulou-Karagianni

2018 ◽  
Vol 23 (1) ◽  
Author(s):  
Marcelo Bonifácio da Silva Sampieri ◽  
Danilo Da Silva Correa ◽  
Francisca Lívia Parente Viana ◽  
Thaís Sumie Nozu Imada ◽  
Josfran Da Silva Ferreira Filho ◽  
...  

Objective: it is important to evaluate the position andestablish the third molar relationship with the mandibularcanal to minimize the risk of nerve injury and assistin planning the extraction of this tooth. The panoramicradiograph is the standard diagnostic tool for this purpose.However, if it indicates a close relationship betweenthe third molar and the mandibular canal, furtherinvestigation using cone beam computed tomography(CBCT) may be recommended to check the three-dimensionalrelationship between the tooth and the mandibularcanal. Thus, this study aimed to correlate the clinicalfindings (observed in third molar surgeries) to imagingfindings (observed in panoramic radiographs andCBCT). Subjects and method: after the extraction of 20mandibular third molars, the panoramic radiograph andthe cone beam computed tomography were analyzed.Then, the surgical findings were correlated to the imagefindings. Results: It was observed that the radiographicfinding type 2 (darkening of roots) observed in the panoramicradiograph presented a greater relation to theabsence of cortical bone between the mandibular canaland the third molar (CBCT finding), with statistical significance(p