scholarly journals Effect of assistive devices on the precision of digital impressions for implants placed in edentulous maxilla: an in vitro study

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Rena Masu ◽  
Shinpei Tanaka ◽  
Minoru Sanda ◽  
Keita Miyoshi ◽  
Kazuyoshi Baba

Abstract Purpose To examine the effect of assistive devices on the precision of digital impression for multiple implants placed in the edentulous maxilla. Methods A reference model representing an edentulous maxilla with four implants was developed. The digital impression group included three settings: Type 0, without an assistive device; Type 1, with an assistive device connecting only neighboring implants; and Type 2, with an assistive device connecting not only neighboring implants but also the two posterior implants, with perpendicular branches from this bar towards the anterior implants. Digital impressions were made five times for each type using three intraoral scanners (IOSs). For conventional method, silicone impressions and verification jigs were prepared; fabricated plaster models were scanned using a laboratory scanner/industrial 3D scanner. In analysis 1, two-way ANOVA analyzed the effect of IOSs and assistive devices on the precision of digital impressions. In analysis 2, one-way ANOVA compared the silicone impressions, the verification jigs, and the most precise group of digital impressions from analysis 1. Results In analysis 1, the IOS and assistive device type (F = 25.22, p < .0001) effects and the interaction between these two factors (F = 5.64, p = .0005) were statistically significant. In analysis 2, CON, VJ, and digital impression with Type 2 devices (most precise devices in analysis 1) were compared; better precision was obtained by digital impression with Type 2 device than by CON and VJ (F = 30.08, p < .0001). Conclusions For implants placed in an edentulous maxilla, digital impressions with assistive devices can provide better precision compared to silicone impressions and verification jigs.

Healthcare ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 246
Author(s):  
Giordano Celeghin ◽  
Giulio Franceschetti ◽  
Nicola Mobilio ◽  
Alberto Fasiol ◽  
Santo Catapano ◽  
...  

The purpose of this study is to define the accuracy of four intraoral scanners (IOS) through the analysis of digital impressions of a complete dental arch model. Eight metal inserts were placed on the model as reference points and then it was scanned with a laboratory scanner in order to obtain the reference model. Subsequently, the reference model was scanned with four IOS (Carestream 3600, CEREC Omnicam, True Definition Scanner, Trios 3Shape). Linear measurements were traced on an STL file between the chosen reference points and divided into four categories: three-element mesiodistal, five-element mesiodistal, diagonal, and contralateral measurements. The digital reference values for the measurements were then compared with the values obtained from the scans to analyze the accuracy of the IOS using ANOVA. There were no statistically significant differences between the measurements of the digital scans obtained with the four IOS systems for any of the measurement groups tested.


2021 ◽  
pp. 019459982110147
Author(s):  
Ioan A. Lina ◽  
Alexandra Berges ◽  
Rafael Ospino ◽  
Ruth J. Davis ◽  
Kevin M. Motz ◽  
...  

Objective Iatrogenic laryngotracheal stenosis (iLTS) is the pathologic narrowing of the glottis, subglottis, and/or trachea secondary to intubation or tracheostomy related injury. Patients with type 2 diabetes mellitus (T2DM) are more likely to develop iLTS. To date, the metabolomics and phenotypic expression of cell markers in fibroblasts derived from patients with T2DM and iLTS are largely unknown. Study Design Controlled in vitro cohort study. Setting Tertiary referral center (2017-2020). Methods This in vitro study assessed samples from 6 patients with iLTS who underwent surgery at a single institution. Fibroblasts were isolated from biopsy specimens of laryngotracheal scar and normal-appearing trachea and compared with controls obtained from the trachea of rapid autopsy specimens. Patients with iLTS were subcategorized into those with and without T2DM. Metabolic substrates were identified by mass spectrometry, and cell protein expression was measured by flow cytometry. Results T2DM iLTS-scar fibroblasts had a metabolically distinct profile and clustered tightly on a Pearson correlation heat map as compared with non-T2DM iLTS-scar fibroblasts. Levels of itaconate were elevated in T2DM iLTS-scar fibroblasts. Flow cytometry demonstrated that T2DM iLTS-scar fibroblasts were associated with higher CD90 expression (Thy-1; mean, 95%) when compared with non-T2DM iLTS-scar (mean, 83.6%; P = .0109) or normal tracheal fibroblasts (mean, 81.1%; P = .0042). Conclusions Scar-derived fibroblasts from patients with T2DM and iLTS have a metabolically distinct profile. These fibroblasts are characterized by an increase in itaconate, a metabolite related to immune-induced scar remodeling, and can be identified by elevated expression of CD90 (Thy-1) in vitro.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Francesca Cattoni ◽  
Giulia Teté ◽  
Alessandro Mauro Calloni ◽  
Fabio Manazza ◽  
Giorgio Gastaldi ◽  
...  

Abstract Background Aesthetic porcelain veneers proved to be a long-term reliable prosthetic solution, ensuring minimal invasiveness. The use of veneers requires an adhesive cementation technique, so maintaining as much enamel as possible is to ensure lasting success. A diagnostic mock-up is a key tool that allows a preview of the outcome of the aesthetic restoration: it is obtainable both in an analog and digital way. With the recent developments in impression technology and the ever so fast growing use of CAD-CAM technologies it is useful to understand the pros and cons of either one of these techniques (analog and digital) in order to identify the easier and more convenient workflow in aesthetic dentistry. Methods After taking pictures and impressions of the dental arcs of a patient in need of aesthetic rehabilitation, 52 resin models were produced and a digital drawing of the smile was outlined. Both an analog and a digital wax-up were obtained from two of the 52 models: the latter was obtained using digital impressions and a dedicated software. The analog wax-up was then used to produce 25 matrices that have later been used to mould 25 resin mock-ups using a traditional moulding protocol (Control Group - CG). The digital wax-up was used to mill 25 PMMA mock-ups. Each mock-up, both milled and moulded (total 50), was then laid on the other 50 resin models as a digital impression of it was taken. The STL. files of the milled mock-ups were compared with the 3D CAD wax-up made using a specific software. The STL. files of the analog printed mock-ups were compared with the traditional wax-up design. A statistical analysis was carried out to evaluate the difference between the groups. Results The statistical analysis showed a significant difference (P > 0.01) between the mean value of the distance between the points of the overlapping STL. meshes in GC (0.0468 mm) and in TG (Test Group - TG) (0,0109 mm). Conclusions The study showed a difference in accuracy between traditional moulded and milled mock-ups compared to their original wax-up. The data analysis reports that the digital method allows for greater accuracy. Within the limitations of this study, a fully digital workflow is to considered more reliable when it come to creating an esthetic mockup: the digital procedure has been shown to be more accurate than the one made manually which is much more operator dependent and it brings an increase to the chance of error, and that could ultimately affect the final result.


2019 ◽  
Vol 476 (16) ◽  
pp. 2371-2391 ◽  
Author(s):  
Saynaz A. Choudhary ◽  
Nikita Bora ◽  
Dipanjan Banerjee ◽  
Leena Arora ◽  
Anindhya Sundar Das ◽  
...  

Abstract Saturated free fatty acid-induced adipocyte inflammation plays a pivotal role in implementing insulin resistance and type 2 diabetes. Recent reports suggest A2A adenosine receptor (A2AAR) could be an attractive choice to counteract adipocyte inflammation and insulin resistance. Thus, an effective A2AAR agonist devoid of any toxicity is highly appealing. Here, we report that indirubin-3′-monoxime (I3M), a derivative of the bisindole alkaloid indirubin, efficiently binds and activates A2AAR which leads to the attenuation of lipid-induced adipocyte inflammation and insulin resistance. Using a combination of in silico virtual screening of potential anti-diabetic candidates and in vitro study on insulin-resistant model of 3T3-L1 adipocytes, we determined I3M through A2AAR activation markedly prevents lipid-induced impairment of the insulin signaling pathway in adipocytes without any toxic effects. While I3M restrains lipid-induced adipocyte inflammation by inhibiting NF-κB dependent pro-inflammatory cytokines expression, it also augments cAMP-mediated CREB activation and anti-inflammatory state in adipocytes. However, these attributes were compromised when cells were pretreated with the A2AAR antagonist, SCH 58261 or siRNA mediated knockdown of A2AAR. I3M, therefore, could be a valuable option to intervene adipocyte inflammation and thus showing promise for the management of insulin resistance and type 2 diabetes.


2014 ◽  
Vol 33 ◽  
pp. S112
Author(s):  
A.-M. Makhlouf ◽  
P. Meyer ◽  
C. Tran ◽  
Z. Pataky ◽  
J. Philippe ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Tae-Gyung Kim ◽  
Sungtae Kim ◽  
Hyunmin Choi ◽  
Jae-Hoon Lee ◽  
Jae-Hong Kim ◽  
...  

The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P<0.05). No significant difference was observed between the CAD/CAM group and the cast group (P>0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.


Author(s):  
Keunbada Son ◽  
Wan-Sun Lee ◽  
Kyu-Bok Lee

This in vitro study aimed to evaluate the 3D analysis for complete arch, half arch, and tooth preparation region by using four analysis software programs. The CAD reference model (CRM; N = 1 per region) and CAD test models (CTMs; N = 20 per software) of complete arch, half arch, and tooth preparation were obtained by using scanners. For both CRM and CTMs, mesh data other than the same area were deleted. For 3D analysis, four analysis software programs (Geomagic control X, GOM Inspect, Cloudcompare, and Materialise 3-matic) were used in the alignment of CRM and CTMs as well as in the 3D comparison. Root mean square (RMS) was regarded as the result of the 3D comparison. One-way analysis of variance and Tukey honestly significant difference tests were performed for statistical comparison of four analysis software programs (α = 0.05). In half-arch and tooth preparation region, the four analysis software programs showed a significant difference in RMS values (p < 0.001), but in complete-arch region, no significant difference was found among the four software programs (p = 0.139). As the area of the virtual cast for 3D analysis becomes smaller, variable results are obtained depending on the software program used, and the difference in results among software programs are not considered in the 3D analysis for complete-arch region.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Francesco Guido Mangano ◽  
Oleg Admakin ◽  
Matteo Bonacina ◽  
Henriette Lerner ◽  
Vygandas Rutkunas ◽  
...  

Abstract Background The literature has not yet validated the use of intraoral scanners (IOSs) for full-arch (FA) implant impression. Hence, the aim of this in vitro study was to assess and compare the trueness of 12 different IOSs in FA implant impression. Methods A stone-cast model of a totally edentulous maxilla with 6 implant analogues and scanbodies (SBs) was scanned with a desktop scanner (Freedom UHD®) to capture a reference model (RM), and with 12 IOSs (ITERO ELEMENTS 5D®; PRIMESCAN® and OMNICAM®; CS 3700® and CS 3600®; TRIOS3®; i-500®; EMERALD S® and EMERALD®; VIRTUO VIVO® and DWIO®; RUNEYES QUICKSCAN®). Ten scans were taken using each IOS, and each was compared to the RM, to evaluate trueness. A mesh/mesh method and a nurbs/nurbs method were used to evaluate the overall trueness of the scans; linear and cross distances between the SBs were used to evaluate the local trueness of the scans. The analysis was performed using reverse engineering software (Studio®, Geomagics; Magics®, Materialise). A statistical evaluation was performed. Results With the mesh/mesh method, the best results were obtained by CS 3700® (mean error 30.4 μm) followed by ITERO ELEMENTS 5D® (31.4 μm), i-500® (32.2 μm), TRIOS 3® (36.4 μm), CS 3600® (36.5 μm), PRIMESCAN® (38.4 μm), VIRTUO VIVO® (43.8 μm), RUNEYES® (44.4 μm), EMERALD S® (52.9 μm), EMERALD® (76.1 μm), OMNICAM® (79.6 μm) and DWIO® (98.4 μm). With the nurbs/nurbs method, the best results were obtained by ITERO ELEMENTS 5D® (mean error 16.1 μm), followed by PRIMESCAN® (19.3 μm), TRIOS 3® (20.2 μm), i-500® (20.8 μm), CS 3700® (21.9 μm), CS 3600® (24.4 μm), VIRTUO VIVO® (32.0 μm), RUNEYES® (33.9 μm), EMERALD S® (36.8 μm), OMNICAM® (47.0 μm), EMERALD® (51.9 μm) and DWIO® (69.9 μm). Statistically significant differences were found between the IOSs. Linear and cross distances between the SBs (local trueness analysis) confirmed the data that emerged from the overall trueness evaluation. Conclusions Different levels of trueness were found among the IOSs evaluated in this study. Further studies are needed to confirm these results.


Sign in / Sign up

Export Citation Format

Share Document