scholarly journals The diagnostic accuracy of diffusion-weighted magnetic resonance imaging and shear wave elastography in comparison to dynamic contrast-enhanced MRI for diagnosing BIRADS 3 and 4 lesions

Author(s):  
Rasha Wessam Abdel Rahman ◽  
Reham Mohammed Abd ElHai Refaie ◽  
Rasha Mohammed Kamal ◽  
Shaimaa Farouk Lasheen ◽  
Dalia Salaheldin Elmesidy

Abstract Background Breast cancer is one of the leading causes of female morbidity and mortality. Management options vary between lesions of BIRADS categories 3 and 4. Therefore, reliable differentiation would improve outcome. Although sonomammography and contrast-enhanced breast magnetic resonance imaging (CE-MRI) remain the cornerstone for assessment of breast disease, additional, non-invasive techniques can be used to increase the efficiency of evaluation such as shear wave elastography (SWE) and diffusion-weighted magnetic resonance imaging (DW-MRI). This prospective study included 66 breast lesions that were categorized as BIRADS 3 or 4 by ultrasound ± mammography. All lesions were evaluated by SWE, CE-MRI and DW-MRI. For SWE, lesions were evaluated by both qualitative and quantitative methods. For CE-MRI, both morphological and kinematic evaluations were done and for DW-MRI, both qualitative and quantitative assessments were studied. Results of all imaging modalities were correlated to histopathology. Results Thirty-seven out of the examined 66 lesions (56.06%) were categorised as BIRADS 3, out of which 1 (2.7%) turned out to be malignant on histopathology and 36 (97.29%) were proved benign. Twenty-nine (43.93%) were categorized as BIRADS 4, out of which 2 (6.89%) turned out to be benign on pathology and 27 (93.1%) were proved malignant. Morphological and kinematic evaluations of CE-MRI showed 92.59% and 92.86%sensitivity, 94.74% and 84.21% specificity, 92.59 and 81.25%PPV, 94.74 and 94.12% NPV, and 93.85% and 87.88% accuracy respectively. Color-coded scoring of SWE showed indices of 89.29%, 68.42%, 67.57%, 89.66%, and 77.27% respectively. The calculated cut-off value for Emax differentiating benign from malignant was 65.15 kpa, resulting in indices of 96.43%, 57.89%, 95.65%, 62.79%, and 74.24% respectively. For Eratio, the calculated cut-off value was 4.55, resulting in indices of 71.43%, 68.42%, 76.47%, 62.50% and 69.70% respectively. For qualitative evaluation of DW-MRI, indices were 78.57%, 65.79%, 62.86%, 80.65%, and 71.21% respectively. For ADC, the calculated cut-off value was 1.25 × 103 mm2/s, which resulted in indices of 75.00%, 84.21%, 82.05%, 77.78%, and 80.30% respectively. Conclusion CE-MRI showed the best diagnostic performance indices. While, SWE and DW-MRI present variable diagnostic performance, both techniques can be used as an adjunct to other imaging modalities to aid the clinical decision and increase its diagnostic confidence.

2021 ◽  
Vol 9 (7) ◽  
pp. 1781-1786
Author(s):  
Ze’ai Wang ◽  
Yanfeng Wang ◽  
Yuan Wang ◽  
Chaogang Wei ◽  
Yibin Deng ◽  
...  

Biomineralized iron oxide–polydopamine hybrid nanodots are constructed using albumin nanoreactors to facilitate contrast-enhanced T1-weighted magnetic resonance imaging as well as photothermal therapeutic efficacy.


2020 ◽  
pp. 028418512095626
Author(s):  
Lu Yang ◽  
Yuchuan Tan ◽  
Hanli Dan ◽  
Lin Hu ◽  
Jiuquan Zhang

Background The diagnostic performance of diffusion-weighted imaging (DWI) combined with dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) for the detection of prostate cancer (PCa) has not been studied systematically to date. Purpose To investigate the value of DWI combined with DCE-MRI quantitative analysis in the diagnosis of PCa. Material and Methods A systematic search was conducted through PubMed, MEDLINE, the Cochrane Library, and EMBASE databases without any restriction to language up to 10 December 2019. Studies that used a combination of DWI and DCE-MRI for diagnosing PCa were included. Results Nine studies with 778 participants were included. The combination of DWI and DCE-MRI provide accurate performance in diagnosing PCa with pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios of 0.79 (95% confidence interval [CI] = 0.76–0.81), 0.85 (95% CI = 0.83–0.86), 6.58 (95% CI = 3.93–11.00), 0.24 (95% CI = 0.17–0.34), and 36.43 (95% CI = 14.41–92.12), respectively. The pooled area under the summary receiver operating characteristic curve was 0.9268. Moreover, 1.5-T MR scanners demonstrated a slightly better performance than 3.0-T scanners. Conclusion Combined DCE-MRI and DWI could demonstrate a highly accurate area under the curve, sensitivity, and specificity for detecting PCa. More studies with large sample sizes are warranted to confirm these results.


2019 ◽  
Vol 36 (1) ◽  
pp. 37-44
Author(s):  
Jessica T. Prince

This review explores the classification and evaluation of suspicious renal lesions across several radiologic imaging modalities. Diagnostic medical sonography (DMS), computed tomography (CT), magnetic resonance imaging (MRI), and contrast-enhanced ultrasound (CEUS) are the primary modalities used to investigate questionable lesions found within the kidneys. Renal masses may range from completely benign to malignant. They are classified based on many different features and characteristics. These lesions may be simple cystic, complex cystic, or solid in nature. Masses may also exhibit varying degrees of vascularity, septations, and calcifications. The discussed imaging modalities have varying strengths, limitations, and implications for use. Imaging techniques may be used independently or in conjunction to best diagnose and treat a patient with a suspicious renal mass. The aim of this review was to describe the diagnostic value of the imaging modalities (DMS, CT, MRI, and CEUS) and their role in the evaluation of suspicious renal lesions.


Sign in / Sign up

Export Citation Format

Share Document