Bending behavior of fire damaged reinforced concrete slabs strengthened with NSM CFRP rods and repairing material overlay

Author(s):  
Withit Pansuk ◽  
Cao Thi
2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Rakesh Kancharla ◽  
Venkata Rao Maddumala ◽  
T. V. N. Prasanna ◽  
Lokaiah Pullagura ◽  
Ratna Raju Mukiri ◽  
...  

Present technology has been evaluated greatly over the past decades, where new particles are being designed and fabricated to fulfill specific needs. The field of nano- and micromaterials has prospered in many disciplines. It has been recently used in reinforced concrete in the production of high-strength, high-performance concrete. Microsilica (MS) and nanosilica (NS) particles have proven to be highly profitable to the concrete mix. Concrete has become denser with considerable improvement in their mechanical characteristics, particularly compressive strength. This proposed method includes a comparative study of the flexural bending behavior of conventional reinforced concrete (without MS or NS) slabs with other slabs. Each has various mixes of MS and NS particles incorporated into the concrete mix. The material content utilized in the slabs is kept constant by replacing a portion of the cement with an equivalent amount of either NS or MS particles or both. MS particles are altered from 0, 5, and 10% while NS particles are altered from 0, 0.5, and 1.0%. It cracks the widths and has higher final load-bearing capacity.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4622
Author(s):  
Kevin Paolo V. Robles ◽  
Jurng-Jae Yee ◽  
Seong-Hoon Kee

The main objectives of this study are to evaluate the effect of geometrical constraints of plain concrete and reinforced concrete slabs on the Wenner four-point concrete electrical resistivity (ER) test through numerical and experimental investigation and to propose measurement recommendations for laboratory and field specimens. First, a series of numerical simulations was performed using a 3D finite element model to investigate the effects of geometrical constraints (the dimension of concrete slabs, the electrode spacing and configuration, and the distance of the electrode to the edges of concrete slabs) on ER measurements of concrete. Next, a reinforced concrete slab specimen (1500 mm (width) by 1500 mm (length) by 300 mm (thickness)) was used for experimental investigation and validation of the numerical simulation results. Based on the analytical and experimental results, it is concluded that measured ER values of regularly shaped concrete elements are strongly dependent on the distance-to-spacing ratio of ER probes (i.e., distance of the electrode in ER probes to the edges and/or the bottom of the concrete slabs normalized by the electrode spacing). For the plain concrete, it is inferred that the thickness of the concrete member should be at least three times the electrode spacing. In addition, the distance should be more than twice the electrode spacing to make the edge effect almost negligible. It is observed that the findings from the plain concrete are also valid for the reinforced concrete. However, for the reinforced concrete, the ER values are also affected by the presence of reinforcing steel and saturation of concrete, which could cause disruptions in ER measurements


2020 ◽  
pp. 136943322097814
Author(s):  
Xing-lang Fan ◽  
Sheng-jie Gu ◽  
Xi Wu ◽  
Jia-fei Jiang

Owing to their high strength-to-weight ratio, superior corrosion resistance, and convenience in manufacture, fiber-reinforced polymer (FRP) bars can be used as a good alternative to steel bars to solve the durability issue in reinforced concrete (RC) structures, especially for seawater sea-sand concrete. In this paper, a theoretical model for predicting the punching shear strength of FRP-RC slabs is developed. In this model, the punching shear strength is determined by the intersection of capacity and demanding curve of FRP-RC slabs. The capacity curve is employed based on critical shear crack theory, while the demand curve is derived with the help of a simplified tri-linear moment-curvature relationship. After the validity of the proposed model is verified with experimental data collected from the literature, the effects of concrete strength, loading area, FRP reinforcement ratio, and effective depth of concrete slabs are evaluated quantitatively.


2021 ◽  
Vol 3 (6) ◽  
Author(s):  
Elena Marrocchino ◽  
Chiara Telloli ◽  
Alessandra Aprile ◽  
Domenico Capuani ◽  
Davide Malaguti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document