scholarly journals A 6-Year Follow-Up of Fracture Incidence and Volumetric Bone Mineral Density Development in Girls With Turner Syndrome

2017 ◽  
Vol 103 (3) ◽  
pp. 1188-1197 ◽  
Author(s):  
Ondrej Soucek ◽  
Eckhard Schönau ◽  
Jan Lebl ◽  
Johannes Willnecker ◽  
Zdenek Hlavka ◽  
...  

Abstract Context Patients with Turner syndrome (TS) are at risk for osteoporotic fractures. Objective The aims of this study were to assess the incidence of clinically important fractures in girls with TS and prospectively describe the development of volumetric bone mineral density (BMD). Design Peripheral quantitative computerized tomography (pQCT) of the radius every other year over the 6 years of observation. Setting Government-funded university referral center. Participants Thirty-two girls with TS, aged 6 to 16 years, were included in the analyses. Fracture incidence was compared with the data in the general population. Bone density and strength were compared with data from 185 healthy girls. Outcomes The main clinical outcome was the fracture occurrence. The secondary outcomes were the changes in Z-scores of the bone parameters. Results Three girls with TS sustained four fractures during 6 years of observation. The fracture rate in TS was not substantially higher than the downward-biased fracture-rate estimate from age-matched, healthy controls (P = 0.48). Whereas the trabecular BMD Z-score decreased with age (β estimate −0.21 ± 0.04, P < 0.001), total bone cross-sectional area correspondingly increased (+0.16 ± 0.04, P < 0.001), which led to normal bone strength. A positive history of incident fractures was not significantly associated with any of the pQCT-derived bone parameters. Conclusions Current pediatric TS patients that are treated with growth hormone and estrogens are not at risk for osteoporotic fractures. Low BMD in TS may be counterweighted by enlarged bone radius, which leads to normal bone strength at the appendicular skeleton.

2010 ◽  
Vol 25 (5) ◽  
pp. 1017-1028 ◽  
Author(s):  
Kamil E Barbour ◽  
Joseph M Zmuda ◽  
Elsa S Strotmeyer ◽  
Mara J Horwitz ◽  
Robert Boudreau ◽  
...  

Author(s):  
Leon D. Gruenewald ◽  
Vitali Koch ◽  
Simon S. Martin ◽  
Ibrahim Yel ◽  
Katrin Eichler ◽  
...  

Abstract Objectives To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. Key Points •Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).


2011 ◽  
Vol 74 (4) ◽  
pp. 445-452 ◽  
Author(s):  
Ondrej Soucek ◽  
Jan Lebl ◽  
Marta Snajderova ◽  
Stanislava Kolouskova ◽  
Miloslav Rocek ◽  
...  

2013 ◽  
Vol 10 (3) ◽  
pp. 396-399 ◽  
Author(s):  
Karen Borschmann ◽  
Marco Y. C. Pang ◽  
Sandra Iuliano ◽  
Leonid Churilov ◽  
Amy Brodtmann ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document