Effect of vinblastine and cytochalasin B on the cytoskeletal domains in 3T3 cells

1981 ◽  
Vol 48 (1) ◽  
pp. 55-73
Author(s):  
J.H. Temmink ◽  
H. Spiele

Normal 3T3 cells were exposed to vinblastine and cytochalasin B in an attempt to correlate the morphological changes of the cell surface as seen in the scanning electron microscope with ultrastructural changes of the cytoskeletal elements as seen in critical-point-dried cells in the transmission electron microscope. Special attention was given to the changes in the cytoplasmic domains distinguished in a previous paper. Cytochalasin B primarily affects the ultrastructure of the cytocortical domain by inducing the formation of condensation foci on the cytoplasmic material. Vinblastine not only induces the depolymerization of microtubules and the perinuclear concentration of intermediate filaments, but it also causes the disappearance of stress fibres from the cortical cytoplasm and the widening of the cytocortex at the expense of the endoplasmic domain. These results support the hypothesis that the differentiation in ultrastructural domains is dependent on the spreading of the cells and their adhesion to substrate.

Author(s):  
M. Kersker ◽  
C. Nielsen ◽  
H. Otsuji ◽  
T. Miyokawa ◽  
S. Nakagawa

Historically, ultra high spatial resolution electron microscopy has belonged to the transmission electron microscope. Today, however, ultra high resolution scanning electron microscopes are beginning to challenge the transmission microscope for the highest resolution.To accomplish high resolution surface imaging, not only is high resolution required. It is also necessary that the integrity of the specimen be preserved, i.e., that morphological changes to the specimen during observation are prevented. The two major artifacts introduced during observation are contamination and beam damage, both created by the small, high current-density probes necessary for high signal generation in the scanning instrument. The JSM-890 Ultra High Resolution Scanning Microscope provides the highest resolution probe attainable in a dedicated scanning electron microscope and its design also accounts for the problematical artifacts described above.Extensive experience with scanning transmission electron microscopes lead to the design considerations of the ultra high resolution JSM- 890.


Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.


Author(s):  
S. Takashima ◽  
H. Hashimoto ◽  
S. Kimoto

The resolution of a conventional transmission electron microscope (TEM) deteriorates as the specimen thickness increases, because chromatic aberration of the objective lens is caused by the energy loss of electrons). In the case of a scanning electron microscope (SEM), chromatic aberration does not exist as the restrictive factor for the resolution of the transmitted electron image, for the SEM has no imageforming lens. It is not sure, however, that the equal resolution to the probe diameter can be obtained in the case of a thick specimen. To study the relation between the specimen thickness and the resolution of the trans-mitted electron image obtained by the SEM, the following experiment was carried out.


Author(s):  
Shaopeng Hu ◽  
Jianhua Wang ◽  
Zhen Li ◽  
Huei Chen ◽  
Fei Cu ◽  
...  

Gastritis from returning bile is a common disease, but the reason for the disease is not clear. As the pathologic ultrastructure research progresses, it has drawn attention to the ultrastructural change of cells in gastric mucosa by clinical workers. We observed gastric mucosa tissues of 15 patients suffering from gastritis with a transmission electron microscope (TEM) and a scanning electron microscope (SEM). It is the first report in China that fungus exists in the lamina propria of gastric mucosa tissue. The result is as follows.The gastric mucosa tissues of 15 patients suffering from gastritis were acquired by stomachoscopy. Both TEM and SEM specimens were prepared by the usual methods. Under the TEM, the epithelial surface became higher and larger. Mitochondria of the cells were swollen and cristae were disrupted. There were vacuoles in the cells. The nucleus showed disorder, heterochromatin became darker, and nucleolae could be observed.


Author(s):  
Gao Fengming

Transmission electron microscope(TEM) and scanning electron microscope(SEM) were widely used in experimental tumor studies. They are useful for evaluation of cellular transformation in vitro, classification of histological types of tumors and treating effect of tumors. We have obtained some results as follows:1. Studies on the malignant transformation of mammalian cells in vitro. Syrian golden hamster embryo cells(SGHEC) were transformed in vitro by ThO2 and/or ore dust. In a few days after dust added into medium, some dust crystals were phagocytized. Two weeks later, malignant transformation took place. These cells were of different size, nuclear pleomorphism, numerous ribosomes, increasing of microvilli on cell surface with various length and thickness, and blebs and ruffles(Figs. 1,2). Myelomonocytic leukemic transformation of mouse embryo cells(MEC) was induced in vitro by 3H-TdR. Transformed cells were become round from fusiform. The number of mitochondria and endoplasmic reticulum was reduced, ribosomes and nucleoli increased, shape of nuclei irregular, microvilli increased, and blebs and ruffles appeared(Fig. 3).


Author(s):  
Edward Coyne

Abstract This paper describes the problems encountered and solutions found to the practical objective of developing an imaging technique that would produce a more detailed analysis of IC material structures then a scanning electron microscope. To find a solution to this objective the theoretical idea of converting a standard SEM to produce a STEM image was developed. This solution would enable high magnification, material contrasting, detailed cross sectional analysis of integrated circuits with an ordinary SEM. This would provide a practical and cost effective alternative to Transmission Electron Microscopy (TEM), where the higher TEM accelerating voltages would ultimately yield a more detailed cross sectional image. An additional advantage, developed subsequent to STEM imaging was the use of EDX analysis to perform high-resolution element identification of IC cross sections. High-resolution element identification when used in conjunction with high-resolution STEM images provides an analysis technique that exceeds the capabilities of conventional SEM imaging.


Author(s):  
Hadi M. Hamza Al-Mayali ◽  
Hind A. Abdul Kadhim

Introduction: Echinococcosis and hydatidosis caused by the metacestode of Echinococcus granulosus are among the most important zoonotic diseases in the world. This study aims to study the ultrastructure of fertile hydatid cysts that infect humans using a scanning electron microscope (SEM). Materials and Methods: Twenty samples of human fertile hydatid cysts were collected from the human liver and lung after performing surgery operations and examined with an SEM. Results: The results of the electron microscopy with different magnifications revealed that the laminated layer (LL) consists of sheets that appeared more compact and aligned. The brood capsules appeared, consisting of a net of finger-shaped structures that emerged from bulges of various sizes and shapes. Conclusion: Under a transmission electron microscope, it was found that the LL had a coherent and flexible structure, settling on a three-dimensional microscopic network of hydrophilic fibers, with high humidity. These fibers were arranged irregularly and had a diameter of about 10 nm; therefore, the fibers adjacent to the germinal layer (GL) were possibly attached to microtriches of tegument, which reached a thickness of 1 mm in the LL.


Sign in / Sign up

Export Citation Format

Share Document