The effect of gas turbine coolant modulation on the part load performance of combined cycle plants. Part 2: Combined cycle plant

Author(s):  
T S Kim ◽  
S T Ro

For combined cycle plants that consist of heavy-duty gas turbine and single-pressure heat recovery steam generator, the effect of gas turbine coolant modulation on plant performance is analysed. Two distinct schemes for gas turbine load control are adopted (the fuel-only control and the variable compressor geometry control), based on the gas turbine calculation in Part 1 of this series of papers. Models for heat recovery steam generator and steam turbine are combined with the gas turbine models of Part 1 to result in a complete analysis routine for combined cycles. The purpose of gas turbine coolant modulation is to minimize coolant consumption by maintaining the turbine blade temperatures as high as possible. It is found that the coolant modulation leads to reduction in heat recovery capacity, which decreases steam cycle power. However, since the benefit of coolant modulation for the gas turbine cycle is large enough, the combine cycle efficiency is improved.

Author(s):  
Akber Pasha

In recent years the combined cycle has become a very attractive power plant arrangement because of its high cycle efficiency, short order-to-on-line time and flexibility in the sizing when compared to conventional steam power plants. However, optimization of the cycle and selection of combined cycle equipment has become more complex because the three major components, Gas Turbine, Heat Recovery Steam Generator and Steam Turbine, are often designed and built by different manufacturers. Heat Recovery Steam Generators are classified into two major categories — 1) Natural Circulation and 2) Forced Circulation. Both circulation designs have certain advantages, disadvantages and limitations. This paper analyzes various factors including; availability, start-up, gas turbine exhaust conditions, reliability, space requirements, etc., which are affected by the type of circulation and which in turn affect the design, price and performance of the Heat Recovery Steam Generator. Modern trends around the world are discussed and conclusions are drawn as to the best type of circulation for a Heat Recovery Steam Generator for combined cycle application.


2020 ◽  
Vol 8 (9) ◽  
pp. 726
Author(s):  
Wahyu Nirbito ◽  
Muhammad Arif Budiyanto ◽  
Robby Muliadi

This study explains the performance analysis of a propulsion system engine of an LNG tanker using a combined cycle whose components are gas turbine, steam turbine, and heat recovery steam generator. The researches are to determine the total resistance of an LNG tanker with a capacity of 125,000 m3 by using the Maxsurf Resistance 20 software, as well as to design the propulsion system to meet the required power from the resistance by using the Cycle-Tempo 5.0 software. The simulation results indicate a maximum power of the system of about 28,122.23 kW with a fuel consumption of about 1.173 kg/s and a system efficiency of about 48.49% in fully loaded conditions. The ship speed can reach up to 20.67 knots.


Author(s):  
Akber Pasha

Today the Heat Recovery Steam Generator (HRSG) has become an integral part of the combined cycle or Cogen plant because of its influence on other equipment. Therefore, the optimization of the HRSG has become one of the prime targets to improve the overall efficiency. The paper presents recent developments and concepts used in HRSG design which improve either the efficiency or the range of performance or both. The paper discusses three major areas of a HRSG - Superheater/Reheater, Economizer, and LP Evaporator/Feedwater Preheater. Depending upon the requirement, the user can implement one or more of the concepts to improve the total performance and/or the reliability.


1979 ◽  
Author(s):  
L. F. Fougere ◽  
H. G. Stewart ◽  
J. Bell

Citizens Utilities Company’s Kauai Electric Division is the electric utility on the Island of Kauai, fourth largest and westernmost as well as northernmost of the Hawaiian Islands. As a result of growing load requirements, additional generating capacity was required that would afford a high level of reliability and operating flexibility and good fuel economy at reasonable capital investment. To meet these requirements, a combined cycle arrangement was completed in 1978 utilizing one existing gas turbine-generator and one new gas turbine-generator, both exhausting to a new heat recovery steam generator which supplies steam to an existing steam turbine-generator. Damper controlled ducting directs exhaust gas from either gas turbine, one at a time, through the heat recovery steam generator. The existing oil-fired steam boiler remains available to power the steam turbine-generator independently or in parallel with the heat recovery steam generator. The gas turbines can operate either in simple cycle as peaking units or in combined cycle, one at a time, as base load units. This arrangement provides excellent operating reliability and flexibility, and the most favorable economics of all generating arrangements for the service required.


Author(s):  
Donald A. Kolp ◽  
Charles E. Levey

Zorlu Enerji needed 35 MW of reliable power at a stable frequency to maintain constant speed on the spindles producing thread at its parent company’s textile plant in Bursa, Turkey. In December of 1996, Zorlu selected an LM2500+ combined cycle plant to fill its power-generating requirements. The LM2500+ has output of 26,810 KW at a heat rate of 9,735 Kj/Kwh. The combined cycle plant has an output of 35,165 KW and a heat rate of 7,428 Kj/Kwh. The plant operates in the simple cycle mode utilizing the LM2500+ and a bypass stack and in combined cycle mode using the 2-pressure heat recovery steam generator and single admission, 9.5 MW condensing steam turbine. The generator is driven through a clutch by the steam turbine from the exciter end and by the gas turbine from the opposing end. The primary fuel for the plant is natural gas; the backup fuel is naphtha. Utilizing a load bank, the plant is capable of accepting a 12 MW load loss when the utility breaker trips open; it can sustain this loss while maintaining frequency within 1% on the mill load. The frequency stabilizing capability prevents overspeeding of the spindles, breakage of thousands of strands of thread and a costly shutdown of the mill. A description of the equipment, operation and performance illustrates the unique features of this versatile, compact and efficient generating unit.


2013 ◽  
Vol 34 (4) ◽  
pp. 215-233 ◽  
Author(s):  
Janusz Kotowicz ◽  
Marcin Job

Abstract This paper presents a gas turbine combined cycle plant with oxy-combustion and carbon dioxide capture. A gas turbine part of the unit with the operating parameters is presented. The methodology and results of optimization by the means of a genetic algorithm for the steam parts in three variants of the plant are shown. The variants of the plant differ by the heat recovery steam generator (HRSG) construction: the singlepressure HRSG (1P), the double-pressure HRSG with reheating (2PR), and the triple-pressure HRSG with reheating (3PR). For obtained results in all variants an economic evaluation was performed. The break-even prices of electricity were determined and the sensitivity analysis to the most significant economic factors were performed.


Author(s):  
Sanjay ◽  
Onkar Singh ◽  
B. N. Prasad

This paper reports on the development requirements of gas/steam combined cycle with an aim to achieve plant efficiency greater than 62% through various development possibilities in gas turbine and steam turbine cycle by taking a reference combined cycle configuration (MS9001H gas turbine and three pressure heat recovery steam generator with reheat). The innovative development possibilities include the advanced inlet design to reduce pressure loss, the increase in turbine inlet temperature, use of advanced turbine blade material, increased component efficiency, improved turbine cooling technologies along with better cooling medium, incorporating intercooling, reheat and regeneration either separately or in combination with simple gas turbine cycle using higher compressor pressure ratio, better utilization of heat recovery steam generator, minimum stack temperature, single shaft system configuration, etc. Based on the quantification of each development item, if incorporated in reference cycle, it has been estimated that the combined cycle as the potential to achieve the plant efficiency in excess of 63%.


2007 ◽  
Vol 11 (4) ◽  
pp. 143-156 ◽  
Author(s):  
Kumar Ravi ◽  
Krishna Rama ◽  
Rama Sita

Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is aimed at optimal utilization of the flue gas recovery heat with different heat recovery steam generator configurations of single pressure and dual pressure. The combined cycle efficiency with different heat recovery steam generator configurations have been analyzed parametrically by using first law and second law of thermodynamics. It is observed that in the dual cycle high pressure steam turbine pressure must be high and low pressure steam turbine pressure must be low for better heat recovery from heat recovery steam generator.


Sign in / Sign up

Export Citation Format

Share Document