Absorbed dose in the skin from beta emitters in medical and laboratory containers

1994 ◽  
Vol 67 (793) ◽  
pp. 54-58 ◽  
Author(s):  
A H Beddoe ◽  
M T Kelly
Keyword(s):  
2018 ◽  
Vol 33 (4) ◽  
pp. 380-385
Author(s):  
Marija Jeremic ◽  
Milovan Matovic ◽  
Suzana Pantovic ◽  
Dragoslav Nikezic ◽  
Dragana Krstic

Strong beta emitters, like 90Y, 177Lu labelled peptide, are used for treatment of neuroendocrine tumours where there is a good expression of somatostatin receptors. In this work, MCNP5/X computer software and ORNL human phantoms were used to calculate absorbed dose due to 90Y labelled DOTATOC in the peptide receptor radionuclide therapy. Tumour was considered as a sources of beta radiation and represented as a sphere with diameter of 1-4 cm and 5 cm in liver, pancreas, and lungs. Results are expressed as absorbed dose per unit of cumulated activity, S ? value in units mGy?(MBq?s)?1. The far largest dose is in tumour itself, then in organ which contains the tumour. Doses in other organs, where the metastasis are the most frequent, due to the bremsstrahlung radiation, are much smaller and could be neglected. The largest dose, 8.66?10?3 mGy?(MBq?s)?1 was obtained for tumour with size of 3 cm.


2021 ◽  
Vol 65 (6) ◽  
pp. 66-72
Author(s):  
L Timofeev ◽  
A Maksimov ◽  
O. Kochetkov ◽  
V. Klochkov

Purpose: To adapt traditional method of soft beta emitters’ dose calculation to the individual biological cells, to estimate the value of absorbed dose-rate factors for different tritium compounds on a cellular level. Material and methods: Approximation for point-source function obtained by L.V. Timofeev, G.B. Radzievsky et al. was used to adapt macroscopic beta-particle dosimetry methods to the area of subcellular structures. Results: Using the introduced concept of irradiated cell model base states the analytical expressions for absorbed dose in subcellular structures were suggested for non-uniform activity distributions of soft beta emitters in human tissue. The values of absorbed dose-rate factors for the case of organically bounded tritium confined to the nucleus (1.8 mGy/decay for 3H-thymidine) and for the case of tritiated water uniformly distributed throughout tissue (3.510-3 mGy/decay) were obtained. Conclusion: It can be assumed that traditional method of soft beta emitters’ dose calculation is adapted to the individual biological cells. The proposed methodology is supposed to be used in the future when constructing, based on experimental data, a biokinetic model of the intake of tritium organic compounds in the human body.


2019 ◽  
Vol 98 (Suppl) ◽  
pp. 5-5
Author(s):  
Matheus Zanelatto Junqueira ◽  
Marcelo Tatit Sapienza ◽  
Nelisa Helena Rocha

Introduction: Techniques using PSMA radioligands have emerged as diagnostic and therapeutic alternatives in prostate cancer. Significant adverse events resulting from using beta-emitters such as 177Lu-PSMA for castration-resistant prostate cancer therapy include sialotoxicity and xerostomia. Sialotoxicity ranges from 8% mild to moderate up to 10% interruption of treatment, depending on the compound used, due to the physiological expression of PSMA in the salivary glands and consequent radioligand uptake. Cooling with icepacks emerged as a possible intervention to prevent this event. The rationale is that cold- induced vasoconstriction would lead to a reduction of the perfusion of the gland, similarly to scalp cooling applied in some chemotherapies. Although empirically used in European protocols, the efficacy of this technique was assessed in only one study, with no evidence of success. The objective of this work was to analyze the efficacy of salivary gland cooling in the reduction of PSMA radioligand uptake.Methodology: Unilateral cooling of the salivary glands was performed for 10 prostate cancer patients submitted to PET-CT with Ga68PSMA, a compound used for diagnostic purposes and validated mainly in biochemical recurrence scenario. For cooling, icepacks were coupled to a device that attached them to one of the patient's parotid gland. Cooling started 30 minutes before the injection of the radiopharmaceutical. The test was started 1h after the injection (acquisition t1), with an approximate duration of 30 minutes. A delayed image was made 4h after the injection (acquisition t4). The cooling was suspended just after the t1 acquisition. The packs were replaced every 30 minutes, and their temperature measured and recorded using infrared thermometers, for temperature standardization. Using OsiriX Dicom Viewer software, each of the glands (cooled parotid and control, cooled submandibular and control) was quantitatively assessed by the standardized maximum, mean and peak uptake values (SUVmax, SUVmean, and SUVpeak). The gland was delimited through an isocontour generated from a threshold of 10% of the SUVmax within a defined volume of interest (VOI). These four parameters were compared through the paired Student's T-test using R Commander software.Results: There was no statistically significant reduction in any of the SUV parameters in the cooled glands compared to contralateral controls, both in t1 in t4. Regarding the submandibular glands, there were also found no alterations of statistical relevance, but the means of the three SUV parameters were higher in the cooled glands that in the controls.Discussion: Results indicated no significant reduction of the radiation absorbed dose by cooled salivary glands. Despite the small sample size, that could reduce the ability to detect significant variations, results allow inferring that biological effects, if present, are probably small and of little clinical significance. Therefore, it was considered that results did not justify performing further exams since this is a high cost and complexity technique. The present findings corroborate with the other mentioned study.Conclusion: The cooling of the salivary glands does not significantly reduce their uptake of radiopharmaceuticals, and no evidence supports this technique for sialotoxicity and xerostomia prevention in clinical practice.


2001 ◽  
Vol 40 (01) ◽  
pp. 1-6 ◽  
Author(s):  
M. Zimny ◽  
M. Schreckenberger ◽  
P. Reinartz ◽  
B. Nowak ◽  
E. Ostwald ◽  
...  

Summary Aim of this study was a characterization of radioiodine therapy (RIT) failures in Graves’ disease without simultaneous Carbimazole. Method: 226 patients with a confirmed diagnosis of Graves’ disease received 686.8 ± 376.4 MBq of iodine-131 orally for thyroid ablation. Target dose was 250 Gy. All patients were followed up for 6 months. Therapy failures were compared with successes regarding possible influencing variables initial thyroid volume, thyroid function, immune activity (TRAb), 1-131 uptake, effective half-life, absorbed energy dose, age and gender. Results: 212 of 226 patients (93.8%) were treated successfully, 14 (6.2%) showed a hyperthyroidism relapse within 6 months which required a second radioiodine therapy. A success rate of 92.5% (62/67) could also be achieved with 67 patients who were hyperthyroid at the time of RIT. Compared to the therapy successes, the 14 failures achieved significantly lower absorbed doses (223.8 ±76.6 Gyvs. 285.2 ±82.1 Gy, ρ <0.005), but with no significant differences regarding age, thyroid volume, function or TRAb (all ρ >0.2). Of the 14 failures, η = 8 reached an absorbed dose <200 Gy and η = 1 a dose <250 Gy, although 5 of the failures reached an absorbed dose of >250 Gy. Stepwise logistic regression revealed only absorbed energy dose as a variable significantly influencing therapy success (p <0.005), but no influence of initial thyroid volume, function, TRAb value, age (all ρ >0.2) or gender (p = 0.13). Two-tailed Fisher’s exact test showed no significant influence of gender on success rates (failures/successes: male 1 /36, female 13/176, ρ = 0.48). Conclusions: Except for the absorbed energy dose, no other significant variable influencing the outcome of radioiodine therapy in Graves’ disease without simultaneous Carbimazole could be found. It should be noted, though, that 5 therapy failures (2.2%) reached an absorbed energy dose of >250 Gy.


2006 ◽  
Vol 45 (03) ◽  
pp. 134-138 ◽  
Author(s):  
T. Kull ◽  
N. M. Blumstein ◽  
D. Bunjes ◽  
B. Neumaier ◽  
A. K. Buck ◽  
...  

SummaryAim: For the therapeutic application of radiopharmaceuticals the activity is determined on an individual basis. Here we investigated the accuracy for a simplified assessment of the residence times for a 188Re-labelled anti-CD66 monoclonal antibody. Patients, methods: For 49 patients with high risk leukaemia (24 men, 25 women, age: 44 ± 12 years) the residence times were determined for the injected 188Re-labelled anti-CD66 antibodies (1.3 ± 0.4 GBq, 5–7 GBq/mg protein, >95% 188Re bound to the antibody) based on 5 measurements (1.5, 3, 20, 26, and 44 h p.i.) using planar conjugate view gamma camera images (complete method). In a simplified method the residence times were calculated based on a single measurement 3 h p.i. Results: The residence times for kidneys, liver, red bone marrow, spleen and remainder of body for the complete method were 0.4 ± 0.2 h, 1.9 ± 0.8 h, 7.8 ± 2.1 h, 0.6 ± 0.3 h and 8.6 ± 2.1 h, respectively. For all organs a linear correlation exists between the residence times of the complete method and the simplified method with the slopes (correlation coefficients R > 0.89) of 0.89, 0.99, 1.23, 1.13 and 1.09 for kidneys, liver, red bone marrow, spleen and remainder of body, respectively. Conclusion: The proposed approach allows reliable prediction of biokinetics of 188Re-labelled anti-CD66 monoclonal antibody biodistribution with a single study. Efficient pretherapeutic estimation of organ absorbed dose may be possible, provided that a more stable anti-CD66 antibody preparation is available.


1994 ◽  
Vol 33 (05) ◽  
pp. 206-214 ◽  
Author(s):  
J. Triller ◽  
H. U. Baer ◽  
Livia Geiger ◽  
H. F. Beer ◽  
C. Becker ◽  
...  

SummaryTwenty patients with unresectable hepatocellular carcinoma (HCC) were followed up to 5 years after transarterial radiotherapy with 90Y-resin particles. Diagnostic radioembolizations of 99mTc-macroaggregates facilitated scintigraphic assessment of activity distribution, dose evaluation and final procedural verification. The overall survival rates were 56, 38 and 14% (after 1, 2 and 3 years, resp.). Patients with unifocal HCC and a single feeding artery (n = 7) even presented 83, 67 and 40% (2 alive after 2.75 and 4 years). With multiple arteries (n = 7), the longest survival was 26 months. Patients with multifocal HCC survived up to 33 months after selective radioembolization. Quality of life was improved in all. Survival was positively correlated with absorbed dose but residual/recurrent tumour occurred even after ≥300 Gy. Post-treatment symptoms were minimal (35 applications), pulmonary shunt rates were correctly predicted and pulmonary complications avoided.