scholarly journals Vibration Control Design and Test of Transmission Tower Using the Suspended Tuned Mass Damper

Author(s):  
QING-SHUI GAO ◽  
YI YANG ◽  
CHU ZHANG
Actuators ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 44
Author(s):  
Qi Wang ◽  
Hong-Nan Li ◽  
Peng Zhang

High-rise structures are normally tall and slender with a large height-width ratio. Under the strong seismic action, such a structure may experience violent vibrations and large deformation. In this paper, a spring pendulum pounding tuned mass damper (SPPTMD) system is developed to reduce the seismic response of high-rise structures. This SPPTMD system consists of a barrel limiter with the built-in viscoelastic material and a spring pendulum (SP). This novel type of tuned mass damper (TMD) relies on the internal resonance feature of the spring pendulum and the collision between the added mass and barrel limiter to consume the energy of the main structure. Based on the Hertz-damper model, the motion equation of the structure-SPPTMD system is derived. Furthermore, a power transmission tower is selected to evaluate the vibration reduction performance of the SPPTMD system. Numerical results revealed that the SPPTMD system can effectively reduce structural vibrations; the reduction ratio is greater than that of the spring pendulum. Finally, the influence of the key parameters on the vibration control performance is conducted for future applications.


2011 ◽  
Vol 44 (1) ◽  
pp. 5371-5376 ◽  
Author(s):  
G. Cazzulani ◽  
C. Ghielmetti ◽  
F. Resta ◽  
F. Ripamonti

2019 ◽  
Vol 19 (06) ◽  
pp. 1950056 ◽  
Author(s):  
Li Tian ◽  
Kunjie Rong ◽  
Kaiming Bi ◽  
Peng Zhang

Failures of transmission tower-line systems have frequently occurred during large earthquakes. It is essential to control the excessive vibrations of transmission tower-line systems to ensure their safe operation in such events. This paper numerically investigates the effectiveness of using a novel bidirectional pounding tuned mass damper (BPTMD) to control the seismic responses of transmission tower-line system when subjected to earthquake ground motions. A finite element model of a typical transmission tower-line system with BPTMD is developed using the commercial software ABAQUS, with the accuracy of the results verified against a previous study. The seismic responses of the system with and without BPTMD are calculated. For comparison, the control effect of using the conventional bidirectional tuned mass damper is also calculated and discussed. Finally, a parametric study is performed to investigate the effects of the mass ratio, seismic intensity, gap size and frequency ratio on the seismic response of the system, while optimal design parameters are obtained.


2012 ◽  
Vol 2012 (0) ◽  
pp. _S102033-1-_S102033-4
Author(s):  
Satoshi ROPPONGI ◽  
Satoshi FUJITA ◽  
Keisuke MINAGAWA ◽  
Yuki SHIBASAKI ◽  
Yasuo TSUYUKI ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document