A Bidirectional Pounding Tuned Mass Damper and Its Application to Transmission Tower-Line Systems under Seismic Excitations

2019 ◽  
Vol 19 (06) ◽  
pp. 1950056 ◽  
Author(s):  
Li Tian ◽  
Kunjie Rong ◽  
Kaiming Bi ◽  
Peng Zhang

Failures of transmission tower-line systems have frequently occurred during large earthquakes. It is essential to control the excessive vibrations of transmission tower-line systems to ensure their safe operation in such events. This paper numerically investigates the effectiveness of using a novel bidirectional pounding tuned mass damper (BPTMD) to control the seismic responses of transmission tower-line system when subjected to earthquake ground motions. A finite element model of a typical transmission tower-line system with BPTMD is developed using the commercial software ABAQUS, with the accuracy of the results verified against a previous study. The seismic responses of the system with and without BPTMD are calculated. For comparison, the control effect of using the conventional bidirectional tuned mass damper is also calculated and discussed. Finally, a parametric study is performed to investigate the effects of the mass ratio, seismic intensity, gap size and frequency ratio on the seismic response of the system, while optimal design parameters are obtained.

2013 ◽  
Vol 353-356 ◽  
pp. 2181-2186
Author(s):  
Yu Wei Dai ◽  
Chao Liu ◽  
Wen Feng Li ◽  
Li Tian

The tuned mass damper (TMD) for vibration control of tower subjected to multi-dimensional seismic excitations is studied in this paper. Calculation model of the tuned mass damper is introduced, and the equations of motion of a tower with tuned mass damper are derived, and the calculation parameters of the tuned mass damper are given based on the control structure. According to a practical engineering, the three-dimensional finite element model of a tower is established using SAP2000. Three typical seismic records are selected according the code of seismic design. Vibration control for tower model with tuned mass damper under multi-dimensional seismic excitations is performed by using numerical simulation. The maximum responses of displacement and axial force of the tower structure without and with TMD are obtained. The results show that the TMD could decrease the responses of the tower in three directions, and the tower with TMD can be a reference for tower practice engineering application.


2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Li Tian ◽  
Yujie Zeng

A parametric study of tuned mass dampers for a long span transmission tower-line system under wind loads is done in this paper. A three-dimensional finite element model of transmission tower-line system is established by SAP2000 software to numerically verify the effectiveness of the tuned mass damper device. The wind load time history is simulated based on Kaimal spectrum by the harmony superposition method. The equations of motion of a system with tuned mass damper under wind load excitation are proposed, and the schematic of tuned mass damper is introduced. The effects of mass ratio, frequency ratio, damping ratio, the change of the sag of transmission line, and the robustness of TMD are investigated, respectively. Results show that(1)the change of mass ratio has a greater effect on the vibration reduction ratio than those of frequency ratio and damping ratio, and the best vibration reduction ratio of TMD is not the frequency ratio of 1;(2)the sag-span ratio has an insignificant effect on the vibration reduction ratio of transmission tower when the change of sag-span ratio is not large; and(3)the effect of ice should be considered when the robustness study of TMD is carried out.


2018 ◽  
Vol 22 (4) ◽  
pp. 1007-1017 ◽  
Author(s):  
Li Tian ◽  
Guodong Gao ◽  
Canxing Qiu ◽  
Kunjie Rong

Statistics from past strong earthquakes revealed that electricity transmission towers were vulnerable to earthquake excitations. It is necessary to mitigate the seismic responses of power transmission towers to ensure the safety of such structures. In this research, a novel shape memory alloy-tuned mass damper is proposed, and seismic vibration control of power transmission tower using shape memory alloy-tuned mass damper based on three types of shape memory alloy materials (i.e. NiTi, M-CuAlBe, P-CuAlBe) is analyzed. The detailed three-dimensional finite element model of a power transmission tower incorporated with shape memory alloy-tuned mass damper is developed using numerical simulation software ANSYS. The control effects of shape memory alloy-tuned mass damper on the seismic vibration of power transmission tower are assessed using nonlinear time history analysis method. The interested seismic performance indices include displacement, acceleration, and base shear force. In addition to the shape memory alloy materials, the influence of seismic intensity and frequency ratio are conducted for the optimal design. It is shown that installing shape memory alloy-tuned mass damper well reduced the seismic responses of power transmission tower. The comparison between different shape memory alloys indicated that the damping of the shape memory alloy-tuned mass damper is beneficial to mitigate the vibrations.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Li Tian ◽  
Qiqi Yu ◽  
Ruisheng Ma

The seismic control of power transmission tower-line coupled system subjected to multicomponent excitations is studied in this paper. The schematic of tuned mass damper is introduced, and equations of motion of a system with tuned mass damper under multi-component excitations are proposed. Three-dimensional finite tower-line system models are created based on practical engineering in studying the response of this system without and with control. The time domain analysis takes into account geometric nonlinearity due to finite deformation. The optimal design of the transmission tower-line system with tuned mass damper is obtained according to different mass ratio. The effects of wave travel, coherency loss, and different site conditions on the system without and with control are investigated, respectively.


2013 ◽  
Vol 7 (1) ◽  
pp. 159-163 ◽  
Author(s):  
Li Tian ◽  
Qian Wang ◽  
Qiqi Yu ◽  
Nuwen Xu

In this paper, tuned mass dampers with optimal parameters for long span transmission tower-line system are investigated. Equations of motion for a structure-TMD system are derived, and the parameters of TMD, stiffness and damping are optimized, respectively. According to a real project, three-dimensional finite element models of both transmission tower and transmission tower-line system are created and their vibration performances are analyzed using SAP2000 software, respectively. Wind load time history is simulated based on wind theory. Using numerical simulation, vibration control with optimal tuned mass damper installed in transmission tower-line system is carried out. Time history curves and the maximum responses of system without and with tuned mass damper under wind excitation are analyzed and discussed. The results show that the optimal tuned mass damper could effectively decrease the wind-induced response of long span transmission tower-line system.


2018 ◽  
Vol 2018 ◽  
pp. 1-19 ◽  
Author(s):  
Xiaohan Wu ◽  
Jun Wang ◽  
Jiangyong Zhou

A high four-tower structure is interconnected with a long sky corridor bridge on the top floor. To reduce the earthquake responses and member forces of the towers and sky corridor bridge, a passive control strategy with a friction pendulum tuned mass damper (FPTMD) was adopted. The sky corridor bridge was as the mass of FPTMD. The connection between the towers and the sky corridor bridge was designed as flexible links, where friction pendulum bearings (FPBs) and viscous dampers were installed. Elastoplastic time-history analysis was conducted by using Perform-3D model to look into its seismic behavior under intensive seismic excitation. The optimal design of the FPTMD with varying friction coefficients and radius of friction pendulum bearing (FPB) under seismic excitations was carried out, and the seismic behavior of the structure was also investigated at the same time.Results show that, for this four-tower connected structure, the friction pendulum tuned mass damper (FPTMD) has very well effect on seismic reduction. The structure can meet the seismic resistance design requirements.


2021 ◽  
Vol 9 ◽  
Author(s):  
Jiaxiang Li ◽  
Biao Wang ◽  
Jian Sun ◽  
Shuhong Wang ◽  
Xiaohong Zhang ◽  
...  

Ice shedding causes transmission lines to vibrate violently, which induces a sharp increase in the longitudinal unbalanced tension of the lines, even resulting in the progressive collapse of transmission towers in serious cases, which is a common ice-based disaster for transmission tower-line systems. Based on the actual engineering characteristics of a 500 kV transmission line taken as the research object, a finite element model of a two-tower, three-line system is established by commercial ANSYS finite element software. In the modeling process, the uniform mode method is used to introduce the initial defects, and the collapse caused by ice shedding and its influencing parameters are systematically studied. The results show that the higher the ice-shedding height is, the greater the threat of ice shedding to the system; furthermore, the greater the span is, the shorter the insulator length and the greater the dynamic response of the line; the impact of ice shedding should be considered in the design of transmission towers.


2014 ◽  
Vol 2014 ◽  
pp. 1-10
Author(s):  
Li Tian ◽  
Wenming Wang ◽  
Hui Qian

The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.


Sign in / Sign up

Export Citation Format

Share Document