scholarly journals Development and Validation of an HPLC Method for the Determination of the macrolide antibiotic Clarithromycin using Evaporative Light Scattering Detector in raw materials and Pharmaceutical Formulations

2017 ◽  
Vol 6 (4) ◽  
pp. 133-141 ◽  
Author(s):  
Zampia Tzouganaki ◽  
Michael Koupparis

In this work, ELS-Detector has been used for the development of an HPLC method for the determination of clarithromycin in pharmaceutical formulations (tablets and pediatric suspension). Isocratic reversed phase HPLC approach has been developed using a C-18 column (Waters Spherisorb 5 μm ODS2, 4.6x250 mm) and a mobile phase consisting of acetonitrile / aqueous trifluoroacetic acid as pairing reagent. Experimental parameters (temperature of heated drift tube, flow rate of mobile phase, gas flow rate, mobile phase composition) were optimized. Clarithromycin’ s stability was thoroughly examined in different solvent systems. Using the optimized conditions the working range was 5-100 μg/mL (upper limit can be increased considerably), with a detection limit of 4.5 μg/mL (6x10-6 M). The method was validated as per ICH guidelines. The retention time was 4.7 min. The method was successfully applied for the content assay of clarithromycin formulations.

2020 ◽  
Vol 66 (1) ◽  
pp. 85-90
Author(s):  
Zhaklina Poposka Svirkova ◽  
Zorica Arsova-Sarafinovska ◽  
Aleksandra Grozdanova

Due to the low absorptivity of bile acids, the aim of this study was to develop and validate a simple and sensitive HPLC/UV method for quantification of ursodeoxycholic acid (UDCA) in pharmaceutical formulations. Effective separation was achieved on C18 end–capped column, with gradient elution of a mobile phase composed of 0.001 M phosphate buffer (pH 2.8±0.5) – acetonitrile mix, at flow rate 1.5 mL min-1, UV detection at 200 nm and injection volumes were 50 µL. The proposed HPLC method was fully validated according to the ICH guidelines and it was found to be simple, accurate, precise and robust. Key words: ursodeoxycholic acid, HPLC/UV, pharmaceutical formulations, validation


Author(s):  
PALAKDEEP KAUR ◽  
MOHIT KUMAR ◽  
UTTAM KUMAR MANDAL

Objective: The present study deals with the development, validation and application of a simple, precise and accurate HPLC method for the determination of mycophenolate mofetil in pharmaceutical formulations and microemulsions. Methods: In this method, a simple isocratic mobile phase composition of methanol and water (75:25 v/v) pumped at 1 ml/minute flow rate through Phenomenex C18 column (dimension: 250 4.6 mm and 5 µm particle size) was used. Injection volume was 20 µl and analysis of mycophenolate mofetil was carried out at 250 nm. Results: The coefficient of regression was found to be 0.9996, indicating the linearity of the developed method within a range of 0.1 to 10 µg/ml. The limit of detection (LOD) and the limit of quantization (LOQ) were found to be 3.660ng/ml and 11.091ng/ml, respectively. The results showed that % deviation for change in compositions of the mobile phase, flow rate and temperature was within a range of-5.51 to 10.99%,-3.70 to 8.80% and-5.29 to 10.90%, respectively. The method seemed sensitive to change of temperature (±5 ○C) and methanol composition (±2%) as the results were at the boundary limit of 10% deviation. Conclusion: A simple, precise and accurate HPLC method for the determination of drug content from microemulsion has been developed and validated in accordance with ICH guidelines.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (02) ◽  
pp. 16-20
Author(s):  
L Mohankrishna ◽  
◽  
P. J. Reddy ◽  
B. P Reddy. ◽  
P. Navya

A sensitive and precise HPLC procedure has been developed for the assay of amphotericin B in bulk samples and pharmaceutical formulations by using a C18 column [Kromosil, C18, (5 µm, 4.6mm x 250 mm; Make. Waters)], and mobile phase combination is 1% formic acid in water and acetonitrile in ratio of 45:55 V/V. The procedure has been validated as per the ICH guidelines. The λmax of detection was fixed at 407 nm, so that there was less interference from mobile phase with highest sensitivity according to UV analysis. Calibration plots were linear in the range of 10-100 µg/mL and the LOD and LOQ were 0.02 µg/mL and 0.06 µg/mL respectively. The high recovery and low relative standard deviation confirm the suitability of the method for routine quality control determination of amphotericin B in different formulations.


2021 ◽  
pp. 281-294 ◽  
Author(s):  
Abolghasem Beheshti ◽  
Zahra Kamalzadeha ◽  
Monireh Haj-Maleka ◽  
Meghdad Payaba ◽  
Mohammad Amin Rezvanfar ◽  
...  

Due to the new hopes for treatment of multiple sclerosis (MS) diseases by Teriflunomide (TFN), in this project, a cheap, robust, and fully validated method has been developed both for determination of assay content in API (active pharmaceutical ingredient), and for related impurities analysis (RIA). To operate the method, a common C18, end-capped (250 × 4.6) mm, 5µm liquid chromatography column, was applied. The mobile phase A was prepared by dissolving 2.74 g (20mM) of PDP (potassium dihydrogen phosphate) and 3.72 g (50mM) of PC (potassium chloride) in water (1000 mL). Then, pH was adjusted to 3.0 by adding OPA (ortho-phosphoric acid) 85%; while, the mobile phase B was acetonitrile (ACN) (100%). In order to confirm the experimental data about the λmax of TFN, we have used the Born-Oppenheimer molecular dynamics (BOMD) simulations, quantum mechanics (QM), and TD-DFT calculations. According to the results, the method showed a high level of suitability, specificity, linearity, accuracy, precision, repeatability, robustness, and reliable detection limit.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.


2008 ◽  
Vol 5 (1) ◽  
pp. 58-67 ◽  
Author(s):  
Srinivas Vishnumulaka ◽  
Narasimha Rao Medicherla ◽  
Allam Appa Rao ◽  
G. Edela Srinubabu

A rapid and sensitive RP-HPLC method with UV detection (242 nm) for routine analysis of famciclovir in pharmaceutical formulations was developed. Chromatography was performed with mobile phase containing a mixture of methanol and phosphate buffer (50:50,v/v) with flow rate 1.0 mL min−1. Quantitation was accomplished with internal standard method. The procedure was validated for linearity (correlation coefficient =0.9999), accuracy, robustness and intermediate precision. Experimental design was used for validation of robustness and intermediate precision. To test robustness, three factors were considered; percentage v/v of methanol in mobile phase, flow rate and pH; flow rate, the percentage of organic modifier and pH have considerable important effect on the response. For intermediate precision measure the variables considered were: analyst, equipment and number of days. The RSD value (0.86%,n=24) indicated an acceptable precision of the analytical method. The proposed method was simple, sensitive, precise, accurate and quick and useful for routine quality control.


2011 ◽  
Vol 8 (3) ◽  
pp. 1238-1245 ◽  
Author(s):  
G. Tulja Rani ◽  
D. Gowri Sankar ◽  
P. Kadgapathi ◽  
B. Satyanarayana

A simple, fast, precise, selective and accurate RP-HPLC method was developed and validated for the simultaneous determination of atenolol and indapamide from bulk and formulations. Chromatographic separation was achieved isocratically on a Waters C18 column (250×4.6 mm, 5 µ particle size) using a mobile phase, methanol and water (adjusted to pH 2.7 with 1% orthophosphoric acid) in the ratio of 80:20. The flow rate was 1 mL/min and effluent was detected at 230 nm. The retention time of atenolol and indapamide were 1.766 min and 3.407 min. respectively. Linearity was observed in the concentration range of 12.5-150 µg/mL for atenolol and 0.625-7.5 µg/mL for indapamide. Percent recoveries obtained for both the drugs were 99.74-100.06% and 98.65-99.98% respectively. The method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness. The method developed can be used for the routine analysis of atenolol and indapamide from their combined dosage form.


2011 ◽  
Vol 8 (4) ◽  
pp. 1958-1964 ◽  
Author(s):  
H. R. Prajapati ◽  
P. N. Raveshiya ◽  
J. M. Prajapati

A reversed phase high performance liquid chromatographic (RP–HPLC) method was developed and subsequently validated for the determination of atomoxetine hydrochloride in bulk and pharmaceutical formulation. The separation was done by a PerkinElmer Brownlee analytical C8 column (260 mm x 4.6 mm, 5 µm) using methanol: 50 mM KH2PO2buffer (PH adjusted to 6.8 with 0.1 M NaOH), 80:20 v/v as an eluent. UV detection was performed at 270 nm at a flow rate 1.0 mL/min. The validation of the method was performed, and specificity, reproducibility, precision accuracy and ruggedness were confirmed. The correlation coefficient was found to be 0.997 for atomoxetine hydrochloride. The recovery was in the range of 99.94 to 100.98% and limit of quantification was found to be 5.707 µg/mL. The method is simple, rapid, selective and economical too and can be used for the routine analysis of drug in pharmaceutical formulations.


2012 ◽  
Vol 95 (2) ◽  
pp. 399-405 ◽  
Author(s):  
Jelena Acevska ◽  
Aneta Dimitrovska ◽  
Gjoshe Stefkov ◽  
Katerina Brezovska ◽  
Marija Karapandzova ◽  
...  

Abstract An HPLC method for the separation of six target alkaloids from Papaver somniferum L. (morphine, codeine, oripavine, thebaine, papaverine, and noscapine) was developed, optimized, and validated. The chromatographic behavior of these alkaloids was investigated using a reversed-phase chromatography at acidic and alkaline pH. The effects of ion-pairing agents, pH value of the mobile phase, concentration of the buffer components, mobile phase organic modifier, and column temperature were studied. Regardless of the large differences in their pKa values, all alkaloids were separated within a close retention window, and good peak shape was achieved for each of the six alkaloids. The proposed method has adequate selectivity, linearity, accuracy, precision, and reproducibility and is applicable for poppy straw.


Sign in / Sign up

Export Citation Format

Share Document