Statistical Structure of the Number of Hot Days on the Georgian Territory

2017 ◽  
Vol 4 (1) ◽  
2017 ◽  
Vol 1 (1) ◽  
pp. 9-17 ◽  
Author(s):  
Sanjay Kale ◽  
N. J. Pawar

Groundwater fluoride and health problem was meticulously studied for dental and skeleton fluorosis except few studies on urolithiasis. Urolithiasis is multi-factorial disease and excess fluoride consumption is one of the causal factors. In view of this, increase of fluoride in groundwater is reported in semiarid Deccan Volcanic Province (DVP), India. To understand the fluoride and urolithiasis association, present study was carried out in Karha river basin of DVP region. Three stages of data generation were adopted for present study such as procuring of medical records of urolithiasis, previous groundwater chemistry data and geochemical investigation of 50 groundwater samples from representative villages. Further, these variables were used for correlation analysis, temporal and spatial distribution to find out their relationships. Result shows medical records of hospitals indicating the gradual increase in urolithiasis is reported during drought situations. In temporal variation, annual fluoride concentration of groundwater and hot days are positively correlated with annual urolith patients as well as spatial study supports the same. In conclusion, present study highlights the relationship of urolith formation with number of hot days, groundwater electrical conductivity and fluoride. However, detailed biomedical study may lead towards understanding of fluoride- urolithiasis relationship.


Author(s):  
Bettoni Roberta ◽  
Valentina Riva ◽  
Chiara Cantiani ◽  
Elena Maria Riboldi ◽  
Massimo Molteni ◽  
...  

AbstractStatistical learning refers to the ability to extract the statistical relations embedded in a sequence, and it plays a crucial role in the development of communicative and social skills that are impacted in the Autism Spectrum Disorder (ASD). Here, we investigated the relationship between infants’ SL ability and autistic traits in their parents. Using a visual habituation task, we tested infant offspring of adults (non-diagnosed) who show high (HAT infants) versus low (LAT infants) autistic traits. Results demonstrated that LAT infants learned the statistical structure embedded in a visual sequence, while HAT infants failed. Moreover, infants’ SL ability was related to autistic traits in their parents, further suggesting that early dysfunctions in SL might contribute to variabilities in ASD symptoms.


2016 ◽  
Vol 9 (6) ◽  
pp. 436-442 ◽  
Author(s):  
Zhao-Hui LIN ◽  
Zheng YU ◽  
He ZHANG ◽  
Cheng-Lai WU
Keyword(s):  

2004 ◽  
Vol 55 (3) ◽  
pp. 253 ◽  
Author(s):  
John B. Gaughan ◽  
M. Shane Davis ◽  
Terry L. Mader

A controlled crossover experimental design was used to determine the effect of altered water sprinkling duration on heifers subjected to heat stress conditions. Heifers were subjected to 3 days of thermoneutral conditions followed by 3 days of hot conditions accompanied by water sprinkling between 1300 and 1500 h (HOT1–3). Then on the following 2 days (HOT4–5), environmental conditions remained similar, but 3 heifers were sprinkled between 1200 and 1600 h (WET) and 3 were not sprinkled (NONWET). This was followed by a 1-day period (HOT6) in which environmental conditions and sprinkling regimen were similar to HOT1–3. Rectal temperature (RT) was collected hourly, and respiration rate (RR) was monitored every 2 h on HOT Days 2, 4, 5, and 6. Dry matter intake and rate of eating were also determined. Sprinkling reduced RR and RT (P < 0.01) of all heifers during HOT1–3. During HOT4–5, WET heifers had lower (P < 0.05) RT than NONWET from 1300 to 700 h and lower RR from 1400 to 2000 h. Dry matter intake of NONWET heifers was reduced by 30.6% (P < 0.05) during HOT4–5 and by 51.2% on HOT6. On HOT4–5 the dry matter intakes of WET heifers were similar to intakes under thermoneutral conditions. During HOT6, RT was again reduced following sprinkling in all heifers. Comparison of RT and RR of NONWET and WET heifers on HOT1–3 v. HOT6 revealed that under similar environmental conditions, NONWET heifers had increased RT, partially due to carry-over from HOT4–5. However, NONWET heifers had 40% lower feed intake but tended to have lower RR on HOT6 v. HOT1–3. Only RR of WET heifers was greater on HOT6, possibly a result of switching from a 4-h back to a 2-h sprinkling period, while maintaining a 62% greater intake (5.80 v. 3.58 kg/day) than NONWET heifers during this time. Results suggest that inconsistent cooling regimens may increase the susceptibility of cattle to heat stress and elicit different physiological and metabolic responses.


PLoS ONE ◽  
2013 ◽  
Vol 8 (2) ◽  
pp. e55459 ◽  
Author(s):  
Pavla Vaneckova ◽  
Hilary Bambrick

Author(s):  
Xinyu Lu ◽  
Chaoxia Yuan ◽  
Mengzhou Yang ◽  
Takeshi Doi ◽  
Md Wahiduzzaman ◽  
...  
Keyword(s):  

Author(s):  
Andrei Lapenis ◽  
George Robinson ◽  
Gregory B. Lawrence

Here we investigate the possible<sup></sup> future response of white spruce (Picea glauca) to a warmer climate by studying trees planted 90 years ago near the southern limit of their climate tolerance in central New York, 300 km south of the boreal forest where this species is prevalent. We employed high-frequency recording dendrometers to determine radial growth phenology of six mature white spruce trees during 2013-2017. Results demonstrate significant reductions in the length of radial growth periods inversely proportional to the number of hot days with air temperature exceeding 30 oC. During years with very hot summers, the start of radial growth began about 3 days earlier than the 2013-2017 average. However, in those same years the end of radial growth was also about 17 days earlier resulting in a shorter (70 versus 100 day), radial growth season. Abundant (350-500 mm) summer precipitation, which resulted in soil moisture values of 20-30% allowed us to dismiss drought as a factor. Instead, a likely cause of reduced radial growth was mean temperature that exceeded daily average of 30<sup> o</sup>C that lead to photoinhibition.


2021 ◽  
Author(s):  
Tim van der Schriek ◽  
Konstantinos V. Varotsos ◽  
Dimitra Founda ◽  
Christos Giannakopoulos

&lt;p&gt;Historical changes, spanning 1971&amp;#8211;2016, in the Athens Urban Heat Island (UHI) over summer were assessed by contrasting two air temperature records from established meteorological stations in urban and rural settings. When contrasting two 20-year historical periods (1976&amp;#8211;1995 and 1996&amp;#8211;2015), there is a significant difference in summer UHI regimes. The stronger UHI-intensity of the second period (1996&amp;#8211;2015) is likely linked to increased pollution and heat input. Observations suggest that the Athens summer UHI characteristics even fluctuate on multi-annual basis. Specifically, the reduction in air pollution during the Greek Economic Recession (2008-2016) probable subtly changed the UHI regime, through lowering the frequencies of extremely hot days (T&lt;sub&gt;max&lt;/sub&gt; &gt; 37 &amp;#176;C) and nights (T&lt;sub&gt;min&lt;/sub&gt; &gt; 26 &amp;#176;C).&lt;/p&gt;&lt;p&gt;Subsequently, we examined the future temporal trends of two different UHIs in Athens (Greece) under three climate change scenarios. A five-member regional climate model (RCM) sub-ensemble from EURO-CORDEX with a horizontal resolution of 0.11&amp;#176; (~12 &amp;#215; 12 km) simulated air temperature data, spanning the period 1976&amp;#8211;2100, for the two station sites. Three future emissions scenarios (RCP2.6, RCP4.5 and RCP8.5) were implanted in the simulations after 2005. The observed daily maximum and minimum air temperature data (T&lt;sub&gt;max&lt;/sub&gt; and T&lt;sub&gt;min&lt;/sub&gt;) from two historical UHI regimes (1976&amp;#8211;1995 and 1996&amp;#8211;2015, respectively) were used, separately, to bias-adjust the model simulations thus creating two sets of results.&lt;/p&gt;&lt;p&gt;This novel approach allowed us to assess future temperature developments in Athens under two different UHI intensity regimes. We found that the future frequency of days with T&lt;sub&gt;max&lt;/sub&gt; &gt; 37 &amp;#176;C in Athens was only different from rural background values under the intense UHI regime. There is a large increase in the future frequency of nights with T&lt;sub&gt;min&lt;/sub&gt; &gt; 26 &amp;#176;C in Athens under all UHI regimes and climate scenarios; these events remain comparatively rare at the rural site.&lt;/p&gt;&lt;p&gt;This study shows a large urban amplification of the frequency of extremely hot days and nights which is likely forced by increasing air pollution and heat input. Consequently, local mitigation policies aimed at decreasing urban atmospheric pollution are expected to be also effective in reducing urban temperatures during extreme heat events in Athens under all future climate change scenarios. Such policies therefore have multiple benefits, including: reducing electricity (energy) needs, improving living quality and decreasing heat- and pollution related illnesses/deaths.&lt;/p&gt;&lt;p&gt;&amp;#160;&lt;/p&gt;


Sign in / Sign up

Export Citation Format

Share Document