scholarly journals Quantum cascade laser absorption spectrometer with low temperature multipass cell for precision clumped CO₂ measurement

2021 ◽  
Author(s):  
Akshay Nataraj ◽  
Michele Gianella ◽  
Ivan Prokhorov ◽  
Bela Tuzson ◽  
Mathieu Bertrand ◽  
...  
2015 ◽  
Vol 8 (8) ◽  
pp. 8859-8902 ◽  
Author(s):  
J. R. Pitt ◽  
M. Le Breton ◽  
G. Allen ◽  
C. J. Percival ◽  
M. W. Gallagher ◽  
...  

Abstract. Spectroscopic measurements of atmospheric N2O and CH4 mole fractions were made on board the FAAM (Facility for Airborne Atmospheric Measurements) large Atmospheric Research Aircraft. We present details of the mid-IR Aerodyne Research Inc. Quantum Cascade Laser Absorption Spectrometer (QCLAS) employed, including its configuration for airborne sampling, and evaluate its performance over 17 flights conducted during summer 2014. Two different methods of correcting for the influence of water vapour on the spectroscopic retrievals are compared and evaluated. A new in-flight calibration procedure to account for the observed sensitivity of the instrument to ambient pressure changes is described, and its impact on instrument performance is assessed. Test flight data linking this sensitivity to changes in cabin pressure is presented. Total 1σ uncertainties of 1.81 ppb for CH4 and 0.35 ppb for N2O are derived. We report a mean difference in 1 Hz CH4 mole fraction of 2.05 ppb (1σ = 5.85 ppb) between in-flight measurements made using the QCLAS and simultaneous measurements using a previously characterised Los Gatos Research Fast Greenhouse Gas Analyser (FGGA). Finally, a potential case study for the estimation of a regional N2O flux using a mass balance technique is identified, and the method for calculating such an estimate is outlined.


2016 ◽  
Vol 9 (1) ◽  
pp. 63-77 ◽  
Author(s):  
J. R. Pitt ◽  
M. Le Breton ◽  
G. Allen ◽  
C. J. Percival ◽  
M. W. Gallagher ◽  
...  

Abstract. Spectroscopic measurements of atmospheric N2O and CH4 mole fractions were made on board the FAAM (Facility for Airborne Atmospheric Measurements) large atmospheric research aircraft. We present details of the mid-infrared quantum cascade laser absorption spectrometer (QCLAS, Aerodyne Research Inc., USA) employed, including its configuration for airborne sampling, and evaluate its performance over 17 flights conducted during summer 2014. Two different methods of correcting for the influence of water vapour on the spectroscopic retrievals are compared and evaluated. A new in-flight calibration procedure to account for the observed sensitivity of the instrument to ambient pressure changes is described, and its impact on instrument performance is assessed. Test flight data linking this sensitivity to changes in cabin pressure are presented. Total 1σ uncertainties of 2.47 ppb for CH4 and 0.54 ppb for N2O are derived. We report a mean difference in 1 Hz CH4 mole fraction of 2.05 ppb (1σ =  5.85 ppb) between in-flight measurements made using the QCLAS and simultaneous measurements using a previously characterised Fast Greenhouse Gas Analyser (FGGA, Los Gatos Research, USA). Finally, a potential case study for the estimation of a regional N2O flux using a mass balance technique is identified, and the method for calculating such an estimate is outlined.


2014 ◽  
Vol 80 (6) ◽  
pp. 833-841 ◽  
Author(s):  
K. Ouaras ◽  
L. Colina Delacqua ◽  
G. Lombardi ◽  
J. Röpcke ◽  
M. Wartel ◽  
...  

The formation of carbon nanoparticles in low pressure magnetized H2/CH4and H2/C2H2plasmas is investigated using infrared quantum cascade laser absorption, mass spectrometry, and electrostatic probe measurements. Results showed that dust formation is correlated to the presence of a significant amount of large positively charged hydrocarbon ions. Large negative ions or neutral hydrocarbon were not observed. These results, along with a qualitative comparison of diffusion and reaction characteristic, suggest that a positive ion may contribute to the growth of nanoparticles in hydrocarbon magnetized plasmas.


2021 ◽  
Author(s):  
Simone Brunamonti ◽  
Manuel Graf ◽  
Lukas Emmenegger ◽  
Béla Tuzson

<p>Water vapor (H<sub>2</sub>O) is the strongest greenhouse gas in our atmosphere, and it plays a key role in multiple processes that affect weather and climate. Particularly, H<sub>2</sub>O in the upper troposphere - lower stratosphere (UTLS) is of great importance to the Earth's radiative balance, and has a significant impact on the rate of global warming. Hence, accurate measurements of UTLS H<sub>2</sub>O are crucial for understanding and projecting climate. Currently, the reference method used for in-situ measurements of UTLS H<sub>2</sub>O aboard meteorological balloons is cryogenic frostpoint hygrometry (CFH) [1]. However, the cooling agent required for this technique (trifluoromethane) is phasing out as of 2020, due to its strong global warming potential. This represents a major challenge for the continuity of global, long-term stratospheric H<sub>2</sub>O monitoring networks, such as the GCOS Reference Upper Air Network (GRUAN).</p><p>As an alternative to CFH, we developed a compact instrument based on mid-IR quantum-cascade laser absorption spectroscopy (QCLAS) [2]. The spectrometer, with a total weight of 3.9 kg, relies on a segmented circular multipass cell [3] that was specifically developed to meet the stringent requirements, in mass, size and temperature resilience, posed by the harsh environmental conditions of the UTLS. Quick response and minimal interference by H<sub>2</sub>O outgassing from surfaces are achieved by an open-path approach. An elaborate thermal management system ensures excellent internal temperature stability, despite of outside temperature variations of up to 80 K.</p><p>In collaboration with the German Weather Service (DWD), two successful test flights were performed in December 2019 in Lindenberg, Germany. We will report on the results of these test flights, highlighting the instrument outstanding capabilities under UTLS and stratospheric conditions (up to 28 km altitude), and identifying some limitations. Further development activities triggered by the test flights, involving both hardware adaptations and spectral analysis modifications, will be also discussed.  The final validation will be addressed, in cooperation with the Swiss Federal Institute of Metrology (METAS), by laboratory experiments in a custom-made climate chamber, using dynamically generated, SI-traceable reference mixtures with H<sub>2</sub>O amount fractions below 20 ppmv and uncertainty < 1%. The ultimate goal is to demonstrate the potential of QCLAS as a highly valuable technique for quantitative balloon-borne measurements of UTLS and stratospheric H<sub>2</sub>O.</p><p>[1] Brunamonti et al. (2019), J. Geophys. Res. Atmos., doi.org/10.1029/2018JD030000.</p><p>[2] Graf et al. (2020), Atmos. Meas. Tech. Discuss., doi.org/10.5194/amt-2020-243 (Accepted 4 January 2021).</p><p>[3] Graf, Emmenegger and Tuzson (2018), Opt. Lett., doi.org/10.1364/OL.43.002434.</p>


Sign in / Sign up

Export Citation Format

Share Document