Simultaneous single-shot measurement of temperature and pressure along a one-dimensional line by use of laser-induced thermal grating spectroscopy

2006 ◽  
Vol 31 (8) ◽  
pp. 1055 ◽  
Author(s):  
Robert Stevens ◽  
Paul Ewart
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Maria Ruchkina ◽  
Dina Hot ◽  
Pengji Ding ◽  
Ali Hosseinnia ◽  
Per-Erik Bengtsson ◽  
...  

AbstractLaser-induced grating spectroscopy (LIGS) is for the first time explored in a configuration based on the crossing of two focused femtosecond (fs) laser pulses (800-nm wavelength) and a focused continuous-wave (cw) laser beam (532-nm wavelength). A thermal grating was formed by multi-photon absorption of the fs-laser pulses by $$\hbox {N}_{{2}}$$ N 2 with a pulse energy around 700 $$\upmu $$ μ J ($$\sim $$ ∼ 45 TW/$$\hbox {cm}^{2}$$ cm 2 ). The feasibility of this LIGS configuration was investigated for thermometry in heated nitrogen gas flows. The temperature was varied from room temperature up to 750 K, producing strong single-shot LIGS signals. A model based on the solution of the linearized hydrodynamic equations was used to extract temperature information from single-shot experimental data, and the results show excellent agreement with the thermocouple measurements. Furthermore, the fluorescence produced by the fs-laser pulses was investigated. This study indicates an 8-photon absorption pathway for $$\hbox {N}_{{2}}$$ N 2 in order to reach the $$\hbox {B}^{3}\Pi _{g}$$ B 3 Π g state from the ground state, and 8 + 5 photon excitation to reach the $$\hbox {B}^{2}\Sigma _{u}^{+}$$ B 2 Σ u + state of the $$\hbox {N}_{2}^{+}$$ N 2 + ion. At pulse energies higher than 1 mJ, the LIGS signal was disturbed due to the generation of plasma. Additionally, measurements in argon gas and air were performed, where the LIGS signal for argon shows lower intensity compared to air and $$\hbox {N}_{{2}}$$ N 2 .


2021 ◽  
Vol 9 ◽  
Author(s):  
José Ángel Picazo-Bueno ◽  
Javier García ◽  
Vicente Micó

Digital holographic microscopy (DHM) is a well-known microscopy technique using an interferometric architecture for quantitative phase imaging (QPI) and it has been already implemented utilizing a large number of interferometers. Among them, single-element interferometers are of particular interest due to its simplicity, stability, and low cost. Here, we present an extremely simple common-path interferometric layout based on the use of a single one-dimensional diffraction grating for both illuminating the sample in reflection and generating the digital holograms. The technique, named single-element reflective digital holographic microscopy (SER-DHM), enables QPI and topography analysis of reflective/opaque objects using a single-shot operation principle. SER-DHM is experimentally validated involving different reflective samples.


2016 ◽  
Vol 70 (6) ◽  
pp. 1034-1043 ◽  
Author(s):  
Anna-Lena Sahlberg ◽  
Johannes Kiefer ◽  
Marcus Aldén ◽  
Zhongshan Li

1984 ◽  
Vol 106 (2) ◽  
pp. 460-466 ◽  
Author(s):  
L. Chiappetta ◽  
M. B. Colket

An aerodynamic quench is the most rapid method for quenching temperature and pressure-dependent chemical reactions. Attempts have been made to quench gas samples aerodynamically, but many of these attempts have been unsuccessful because of a lack of understanding of the internal aerodynamics of sampling probes. A one-dimensional model developed previously by the authors has been used for the design and analysis of aerodynamically quenching probes. This paper presents in detail the important aerodynamic and heat transfer equations used in the model, a description of the method of solution, and the results of a sensitivity study. These calculations demonstrate the limitations and important trade-offs in design and operating conditions of probes using an aerodynamic quench.


2018 ◽  
Vol 5 (5) ◽  
Author(s):  
Yuri Daniel van Nieuwkerk ◽  
Jörg Schmiedmayer ◽  
Fabian Essler

We consider time-of-flight measurements in split one-dimensional Bose gases. It is well known that the low-energy sector of such systems can be described in terms of two compact phase fields \hat{\phi}_{a,s}(x)ϕ̂a,s(x). Building on existing results in the literature we discuss how a single projective measurement of the particle density after trap release is in a certain limit related to the eigenvalues of the vertex operator e^{i\hat{\phi}_a(x)}eiϕ̂a(x). We emphasize the theoretical assumptions underlying the analysis of “single-shot” interference patterns and show that such measurements give direct access to multi-point correlation functions of e^{i\hat{\phi}_a(x)}eiϕ̂a(x) in a substantial parameter regime. For experimentally relevant situations, we derive an expression for the measured particle density after trap release in terms of convolutions of the eigenvalues of vertex operators involving both sectors of the two-component Luttinger liquid that describes the low-energy regime of the split condensate. This opens the door to accessing properties of the symmetric sector via an appropriate analysis of existing experimental data.


2018 ◽  
Vol 25 (1) ◽  
pp. 68-71 ◽  
Author(s):  
Shigeki Owada ◽  
Kyo Nakajima ◽  
Tadashi Togashi ◽  
Tetsuo Kayatama ◽  
Makina Yabashi

Arrival timing diagnostics performed at a soft X-ray free-electron laser (FEL) beamline of SACLA are described. Intense soft X-ray FEL pulses with one-dimensional focusing efficiently induce transient changes of optical reflectivity on the surface of GaAs. The arrival timing between soft X-ray FEL and optical laser pulses was successfully measured as a spatial position of the reflectivity change. The temporal resolution evaluated from the imaging system reaches ∼10 fs. This method requires only a small portion of the incident pulse energy, which enables the simultaneous operation of the arrival timing diagnostics and experiments by introducing a wavefront-splitting scheme.


2005 ◽  
Vol 43 (12) ◽  
pp. 1305-1314 ◽  
Author(s):  
M. de Angelis ◽  
S. De Nicola ◽  
P. Ferraro ◽  
A. Finizio ◽  
S. Grilli ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document