scholarly journals Validity of protein-creatinine and protein-osmolality ratios in the estimation of massive proteinuria in children with nephrotic syndrome

2007 ◽  
Vol 47 (4) ◽  
pp. 139
Author(s):  
M. Sukmawati ◽  
K. Suarta

Background Children with nephrotic syndrome have massiveproteinuria, a rate of excretion equal to or greater than 40 mg/hour/m 2 body surface. The ability to quantitate massive urinaryprotein excretion is very important for both diagnostic andprognostic purposes. Quantification of proteinuria using 24-hoururine collection (Esbach) is difficult to do especially in children;moreover, many false-positive and false-negative results arereported for any semi-quantitative methods such as dipstick andsulfosalicylic acid measurement.Objective To determine the accuracy of protein-creatinine ratio(PCR) and protein-osmolality ratio (POR) in quantification ofmassive proteinuria in children with nephrotic syndrome.Methods Diagnostic tests were conducted on children withnephrotic syndrome aged 2-12 years with Esbach as a referencestandard. Sensitivity, specificity, positive predictive value (PPV),negative predictive value, (NPV), pre and posttest probabilitywere compared between PCR and POR.Results Study patients consisted of 47 children, 38 (81%) withmassive proteinuria. PCR has sensitivity of 92%, specificity of78%, PPV of 95%, NPV of 70% and posttest probability of 95%.POR has sensitivity of 76%, specificity of 78%, PPV of 94%, NPVof 44% and posttest probability of 94%.Conclusion Both PCR and POR are accurate to determine massiveproteinuria in children with nephrotic syndrome.

2017 ◽  
Vol 38 (06) ◽  
pp. 619-625 ◽  
Author(s):  
Lukas Beyer ◽  
Florian Wassermann ◽  
Benedikt Pregler ◽  
Katharina Michalik ◽  
Janine Rennert ◽  
...  

Abstract Aim The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). Methods 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 – 6 MHz) after the injection of 1 – 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. Results The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. Conclusion CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods.


2015 ◽  
Vol 53 (12) ◽  
pp. 3828-3833 ◽  
Author(s):  
Michael Hombach ◽  
Barbara von Gunten ◽  
Claudio Castelberg ◽  
Guido V. Bloemberg

This study evaluated the performance of the Rapidec Carba NP test, which was introduced recently into the market for the detection of carbapenemase production in a broad spectrum of β-lactamase-producingEnterobacteriaceaeclinical isolates. In total, 252 clinicalEnterobacteriaceaeisolates that had been genetically characterized with respect to carbapenemase, extended-spectrum β-lactamase (ESBL), and AmpC genes were analyzed; 51/252 isolates (20.2%) were genetically confirmed to be carbapenemase producers, whereas 201/252 isolates (79.8%) were genetically negative for the presence of carbapenemase genes. The Rapidec Carba NP test was applied according to the manufacturer's instructions, and results were read after 30 and 120 min of incubation. The overall sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the Rapidec Carba NP test were 90.2%, 100%, 100%, and 97.6%, respectively, when the manufacturer's instructions were followed. Four of 5 false-negative results occurred with OXA-48-like enzymes. After an incubation time of 30 min, the sensitivity was 49%. The sensitivity increased to 100% when the recommended bacterial inoculum was doubled and the test was read strictly after 120 min of incubation. The Rapidec Carba NP test is a useful tool for the reliable confirmation of carbapenemase-producingEnterobacteriaceaeisolates. The test should be read strictly after 120 min of incubation and the inoculum should be larger than recommended by the manufacturer.


2013 ◽  
Vol 57 (9) ◽  
pp. 4578-4580 ◽  
Author(s):  
Nathalie Tijet ◽  
David Boyd ◽  
Samir N. Patel ◽  
Michael R. Mulvey ◽  
Roberto G. Melano

ABSTRACTThe Carba NP test was evaluated against a panel of 244 carbapenemase- and non-carbapenemase-producingEnterobacteriaceaeandPseudomonas aeruginosaisolates. We confirmed the 100% specificity and positive predictive value of the test, but the sensitivity and negative predictive value were 72.5% and 69.2%, respectively, and increased to 80% and 77.3%, respectively, using a more concentrated bacterial extract. False-negative results were associated with mucoid strains or linked to enzymes with low carbapenemase activity, particularly OXA-48-like, which has emerged globally in enterobacteria.


2019 ◽  
Vol 57 (02) ◽  
pp. 133-138
Author(s):  
Eva-Marie Warnken ◽  
Michael Uder ◽  
Hubert Stein ◽  
Michael Wucherer ◽  
Michael Lell ◽  
...  

Abstract Purpose The goal of this study was to evaluate the experience of 11 years of wire-guided forceps biopsy via PTCD in patients with obstructive jaundice. Materials and methods In a retrospective approach, 56 biopsies in 51 patients were analyzed (22 female, 29 male). Data was collected from 2006 to 2016. Mean age was 71 years (range: 34 – 86 years). Data was extracted from dig. Patients’ records (KIS, PACS, RIS) to be analyzed in Microsoft Excel. Results All 56 procedures were technically successful. Stenosis in anastomoses were benign due to scarring in 7 patients and in 9 due to papillitis or others. In 4 patients, results in anastomosis were malignant. In 19 patients without anastomosis, CCC was the diagnosis, thereof 10 klatskin, 9 stenosis in other locations, followed by gastric, pancreatic, and colon carcinoma in 5, 3, and 2 patients. Three patients had a CUP (multimetering in case of more than 1 related category). Overall results were 35 mal. and 16 benign, 76.8 % of all proc. had a correct histopathologic result, and 23.2 % were false negative. Sensitivity was 65.8 %, which results in negative predictive value of 58.1 %. There was no false positive and so specificity was 100 %, as was the positive predictive value. False negative results (no malignancy but clinically and imaging suspect) were corrected by rerunning the procedure, by CT-guided biopsy or by 1 PET-CT. In 1 case the surg. sample brought the result. Minor complications occurred in 8 patients: shivering in 1 case, distinct but hemodynamically not relevant hemobilia in 5 cases, 2 portovenal bleedings. All bleedings were short-term and self-limiting. Conclusion Despite good feasibility, low peri- and post-interv. risk and high validity the forceps biopsy via PTCD is not widely used. For experienced interventionalists, it is an effective method for obtaining histology.


2015 ◽  
Vol 9 (03) ◽  
pp. 321-324 ◽  
Author(s):  
Lurdes Santos ◽  
Nuno Rocha Pereira ◽  
Paulo Andrade ◽  
Paulo Figueiredo Dias ◽  
Carlos Lima Alves ◽  
...  

Malaria diagnosis remains a concern in non-endemic countries, with rapid diagnosis being crucial to improve patients’ outcome. Rapid diagnostic tests have high sensitivity but they also have flaws and false-negative results that might jeopardize malaria diagnosis. Some false-negative results might relate to a prozone-like effect. The authors describe two patients with false-negative rapid diagnostic tests in which a prozone-like effect might have been involved. The authors highlight that these tests should not be used without accompanying light microscopy observation of blood films and discuss potential benefits of using rapid diagnostic tests with more than one specific antigen for Plasmodium falciparum.


2018 ◽  
Vol 10 (3) ◽  
pp. 217-21
Author(s):  
Emy Noerwidayati ◽  
Andaru Dahesihdewi ◽  
Osman Sianipar

BACKGROUND: Klepsiella pneumoniae, one of clinical isolates, is frequently found causative agent of hospital acquired infection. Currently, K. pneumoniae is found as extended-Spectrum β-lactamases (ESBL) producer, allowing it to become multidrugresistant. A clinical laboratory with limited facility needs a valid, reliable, inexpensive and simple laboratory test to control its infection and antimicrobial-resistancy. The aim of this study is to evaluate the diagnostic performance of a ESBL media to detect ESBL-producing K. pneumoniae.METHODS: An independent and blind comparative study of ChromID ESBL media and Double Disc Synergy Test (DDST) was conducted for detecting the clinical isolate of ESBL-producing K. pneumoniae. Clinical isolates of K. pneumoniae collected from the Clinical Laboratory of Dr. Sardjito Hospital were isolated.RESULTS: There were 103 clinical isolates of K. pneumoniae, which were isolated from urine, pus, blood, stool, cerebrospinal fluid, sputum, drain liquid, nasal sinus liquid, gastric wash, bronchi liquid, injury liquid and nasal swab. The number of true positive, true negative, false positive and false negative results were 74, 18, 9 and 2, respectively. Meanwhile, the sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratio for positive result and likelihood ratio for negative result of the new ESBL media were 97.4%, 66.7%, 89.2%, 90%, 2.9 and 0.03, respectively.CONCLUSION: Since the new ESBL media and DDST results were similar, so the new ESBL media could be used for screening patients with clinical presentation that indicating a high suspicious of ESBL-producing bacteria.KEYWORDS: K. pneumoniae, ChromID ESBL, DDST, ESBL, sensitivity


2022 ◽  
Author(s):  
Elsayed Ghannam ◽  
Salah Rozaik ◽  
Ramy Hasan Agwa ◽  
Ahmed Marwan ◽  
Mervat El-Sayed Mashaly ◽  
...  

Abstract Background: Liver is the largest endocrine organ in the body. It is a key organ in insulin mediated metabolism, growth hormone and insulin like growth factors (IGF) pathway. Liver cirrhosis is the end result of many chronic diseases including hepatitis C virus infection. Child-Turcotte-Pugh (CTP) score is the standard used in assessment of hepatic reserve but it has its drawbacks in the form of subjective variables, hepatic encephalopathy and ascites. The aim of this work is to assess IGF-1 in patients with liver cirrhosis, correlate it with CTP score and assess value of modified combined CTP-IGF-1 score. Patients and Methods: 170 patients with CLD (liver cirrhosis) and 72 healthy controls in the study groups were enrolled in the study. All patients were subjected to thorough history, clinical examination and laboratory assessment. IGF-1 was measured and all patients were evaluated using CTP and CTP-IGF-1 scores. Results: IGF1 showed highly significant low values in the study group in comparison to controls (42.15 ± 27.976 and 66.31 ± 33.084 ng/ml respectively, p <0.001). It showed also highly significant negative correlation to CTP score in the study group (p < 0.001) with progressive decrements with CTP score stage progression where IGF1 levels were 48.32 ± 28.611, 40.28 ± 25.869 and 18.80 ± 15.953 ng/ml (mean ± standard deviation) in relation to CTP score groups A, B and C respectively (p value < 0.001). The combined CTP-IGF-1 score in comparison to the classic CTP score showed improved area under curve (0.848 and 0.854), sensitivity (71.2% and 88%), negative predictive value (41.7% and 53.7%), false negative results (49 and 19) and accuracy (75.73% and 83.98%) but decreased specificity (97.22% and 61.1%), positive predictive value (99.2% and 91.5%) and higher false positive results (1 and 14) respectively. Conclusion: IGF-1 show progressive decrements with progression of liver cirrhosis and is negatively correlated with CTP score. Addition of IGF-1 to CTP score to formulate combined score improves the AUC, sensitivity, negative predictive value and the accuracy of CTP score and decreases the false negative results.


2020 ◽  
Vol 66 (8) ◽  
pp. 1055-1062 ◽  
Author(s):  
Mei San Tang ◽  
Karl G Hock ◽  
Nicole M Logsdon ◽  
Jennifer E Hayes ◽  
Ann M Gronowski ◽  
...  

Abstract Background The recent emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a rapid proliferation of serologic assays. However, little is known about their clinical performance. Here, we compared two commercial SARS-CoV-2 IgG assays. Methods 103 specimens from 48 patients with PCR-confirmed SARS-CoV-2 infections and 153 control specimens were analyzed using SARS-CoV-2 serologic assays by Abbott and EUROIMMUN (EI). Duration from symptom onset was determined by medical record review. Diagnostic sensitivity, specificity, and concordance were calculated. Results The Abbott SARS-CoV-2 assay had a diagnostic specificity of 99.4% (95% CI; 96.41–99.98%), and sensitivity of 0.0% (95% CI; 0.00–26.47%) at &lt;3 days post symptom onset, 30.0% (95% CI; 11.89–54.28) at 3–7d, 47.8% (95% CI; 26.82–69.41) at 8–13d and 93.8% (95% CI; 82.80–98.69) at ≥14d. Diagnostic specificity on the EI assay was 94.8% (95% CI; 89.96–97.72) if borderline results were considered positive and 96.7% (95% CI; 92.54–98.93) if borderline results were considered negative. The diagnostic sensitivity was 0.0% (95% CI; 0.00–26.47%) at &lt;3d, 25.0% (95% CI; 8.66–49.10) at 3–7d, 56.5% (95% CI; 34.49–76.81) at 3–7d and 85.4% (95% CI; 72.24–93.93) at ≥14d if borderline results were considered positive. The qualitative concordance between the assays was 0.83 (95% CI; 0.75–0.91). Conclusion The Abbott SARS-CoV-2 assay had fewer false positive and false negative results than the EI assay. However, diagnostic sensitivity was poor in both assays during the first 14 days of symptoms.


Author(s):  
Chandralekha Janagam ◽  
Bhagyalakshmi Atla

Background: The objectives of this study were to examine the validity of ascitic fluid cytology in the detection of pathological findings, to examine the percentage of false positive and false negative results in the cytology of ascitic fluid and to determine the validity of peritoneal cytology in relation to the histopathological type of the ovarian tumour.Methods: This retrospective study, over a period of 6 months, included 106 peritoneal cytology findings. The experimental group included 106 cytology findings obtained from patients who presented with an abdominal lump/mass with ascites and diagnosed with ovarian tumors clinically. They included 88 benign ovarian tumours (83%) and 18 malignant ovarian tumors (17%). Patients with other causes of ascites were excluded from the study.Results: The sensitivity of peritoneal cytology is 90%, specificity is 96.5%, positive predictive value is 85.7%, and negative predictive value is 97.6%. In 1.8% of patients, the peritoneal cytology showed false negative results, while in 2.8%, the results were false positive. False negative results were found in one case of teratoma with squamous cell carcinoma and one case of yolk sac tumor. False positive results were found in 2 cases of tuberculous-salpingo- oophoritis and one case of chronic salpingo-oophoritis due to reactive mesothelial proliferation, mistaken for adenocarcinoma.Conclusions: Peritoneal cytology of ascitic fluid is highly specific and sensitive for detection of ovarian malignancies, particularly in grade 3 and grade 4 disease, since most of the patients with ovarian malignancies present to us at advanced stage of the disease.


Sign in / Sign up

Export Citation Format

Share Document