scholarly journals Vector Analysis of Electrical Networks for Temperature Measurement of MOS Power Transistors

2021 ◽  
Vol 25 (4) ◽  
pp. 83-87
Author(s):  
Błażej Torzyk ◽  
Bogusław Więcek

The article presents the concept of using VNA (Vector Network Analyzer) to measure the temperature of the MOS transistor junction. The method assumes that the scattering parameters of the network consisting of the transistor depend on the temperature. The tests confirmed the influence of temperature on the S11 parameter and the input network capacity during ambient temperature changes in the range of 35–70 °C. Measurements were made for the gate-source (G-S) input of the system. The measurements were carried-out with the transistor in the ON/OFF states. In order to validate the measurements, the temperature of the tested element was recorded with the MWIR Cedip-Titanium thermal imaging camera.

2018 ◽  
Vol 178 ◽  
pp. 06014
Author(s):  
Valentin Amortila ◽  
Elena Mereuta ◽  
Silvia Veresiu ◽  
Madalina Rus ◽  
Costel Humelnicu

The aim of this paper is to analyze driver's hands coordinates on the steering wheel for an optimal and safe driving experience. A good coordination of the driver's action on the controls is the result of a comfortable position that leads to an optimal reaction while driving. The presented study implies using a thermal imaging camera for analysing palms temperature changes in the contact area with the steering wheel. The resulting data shows that the optimal driving position of drivers' hands is 0° and 180° associating the steering wheel with and trigonometric circle.


Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7068
Author(s):  
Agnieszka Baic ◽  
Dominika Plaza ◽  
Barbara Lange ◽  
Marta Reudelsdorf-Ullmann ◽  
Łukasz Michalecki ◽  
...  

The aim of the study was to evaluate the temperature parameter of the breast area in patients undergoing radiotherapy at various intervals. The relationship between temperature changes on the patient’s skin and the time after the end of radiotherapy was studied. Measurements with a thermal imaging camera were performed in a group of twelve volunteers. Six of them were healthy women who did not have thermal asymmetry between the breasts, whereas six were diagnosed with breast cancer and underwent mastectomy due to the advanced stage of the disease. The patients were qualified for radiation therapy. Thermographic examinations were performed before treatment, two months later and then six months after the end of the treatment. Temperature differences between the healthy breasts and the treated areas were assessed. Additionally, the correlation between a patient’s skin temperature changes and the time after the end of radiotherapy was analyzed. The highest skin temperature increase (1.47 °C) was observed 6 months after the end of RT compared to the measurement before treatment. It seems that thermovision may bring a new tool for quantitative analyses of the temperature effects of radiotherapy.


2021 ◽  
pp. 112067212110237
Author(s):  
Ari Leshno ◽  
Ori Stern ◽  
Yaniv Barkana ◽  
Noa Kapelushnik ◽  
Reut Singer ◽  
...  

Purpose: Accumulating evidence suggests that neuroinflammation and immune response are part of the sequence of pathological events leading to optic nerve damage in glaucoma. Changes in tissue temperature due to inflammation can be measured by thermographic imaging. We investigated the ocular surface temperature (OST) profile of glaucomatous eyes to better understand the pathophysiology of these conditions. Methods: Subjects diagnosed with glaucoma (primary open angle glaucoma [POAG] or pseudo exfoliation glaucoma [PXFG]) treated at the Sam Rothberg Glaucoma Center (11/2019–11/2020.) were recruited. Healthy subjects with no ocular disease served as controls. The Therm-App thermal imaging camera was used for OST acquisition. Room and body temperatures were recorded, and the mean temperatures of the medial cantus, lateral cantus, and cornea were calculated with image processing software. Results: Thermographic images were obtained from 52 subjects (52 eyes: 25 POAG and 27 PXFG) and 66 controls (66 eyes). Eyes with glaucoma had a significantly higher OST compared to controls (mean 0.9 ± 0.3°C, p < 0.005). The difference between the two groups remained significant after adjustment for age, sex, intraocular pressure (IOP) and room and body temperatures. Lens status and topical IOP-lowering medication did not significantly affect OST. A subgroup analysis revealed that the OST was higher among eyes with POAG compared to eyes with PXFG, but not significantly. Conclusions: Differences in the OST between glaucomatous and normal eyes strengthens current thinking that inflammation affects the pathophysiology of glaucoma. Longitudinal studies are warranted to establish the prognostic value of thermographic evaluations in these patients.


Author(s):  
Yiqun Huang ◽  
Pawan Singh Takhar ◽  
Juming Tang ◽  
Barry G Swanson

Rheological behaviors of high acyl (HA) gellan are not well understood partially because of its relatively late commercialization compared to low acyl gellan. The objective of this study was to investigate the effect of temperature (5-30 °C), calcium (0, 1 and 10 mM) and gellan concentrations (0.0044-0.1000% w/v) on the flow behaviors of high acyl gellan aqueous solutions using rheological tests. Gellan solutions with 0 or 1 mM added Ca++ exhibited shear thinning behavior at gellan concentrations above 0.0125%. The influence of temperature on apparent viscosity (shear rate, 100 s-1) of gellan solutions can be described with an Arrhenius relationship. The apparent viscosity of gellan solution at low concentrations was more sensitive to temperature changes. The addition of Ca++ led to a decrease in flow resistance for a dilute gellan solution (<0.0125%), but an increased resistance for a relatively concentrated gellan solution (>0.0125%).


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3258
Author(s):  
Dawid Szurgacz ◽  
Sergey Zhironkin ◽  
Stefan Vöth ◽  
Jiří Pokorný ◽  
A.J.S. (Sam) Spearing ◽  
...  

The paper discusses the results of a study carried out to determine the thermal condition of a conveyor power unit using a thermal imaging camera. The tests covered conveyors in the main haulage system carrying coal from a longwall. The measurements were taken with a thermal imaging diagnostic method which measures infrared radiation emitted by an object. This technology provides a means of assessing the imminence and severity of a possible failure or damage. The method is a non-contact measuring technique and offers great advantages in an underground mine. The thermograms were analysed by comparing the temperature distribution. An analysis of the operating time of the conveyors was also carried out and the causes of the thermal condition were determined. The main purpose of the research was to detect changes in thermal state during the operation of a belt conveyor that could indicate failure and permit early maintenance and eliminate the chance of a fire. The article also discusses the construction and principle of operation of a thermal imaging camera. The findings obtained from the research analysis on determining the thermal condition of the conveyor drive unit are a valuable source of information for the mine’s maintenance service.


Author(s):  
Avadhesh Kumar Sharma ◽  
Mayank Modak ◽  
Santosh K. Sahu

Impinging jets are commonly utilized in the run-out table (ROT) cooling in the hot rolling process in steel manufacturing industries. The phenomenon of rapid cooling of a sufficiently hot surface is termed as the quenching. The present paper reports the rewetting behavior of 0.15 mm thick hot moving stainless steel foil (SS-304) by circular impinging jet from bottom side through experimental investigation. The transient temperature of the hot foil is recorded by using thermal imaging camera (A655sc, FLIR system). Tests are performed for a varied range of Reynolds number (Re = 2500–10000), nozzle to plate distance (z/d = 6), moving plate velocity (0–40 mm/s) and initial surface temperature 500±10 °C. Transient temperature obtained from thermal imaging camera is used to evaluate rewetting time and rewetting velocity. Based on the experimental investigation correlation has been proposed to predict non-dimensional rewetting velocity as a function of various parameters, namely, Reynolds number, non-dimensional axial distance and moving plate velocity.


Author(s):  
M. Fatih Toy ◽  
Onur Ferhanoglu ◽  
Hamdi Torun ◽  
F. Levent Degertekin ◽  
Hakan Urey

2018 ◽  
Vol 155 ◽  
pp. 01007
Author(s):  
Olga Dotsenko ◽  
Kirill Frolov

The vector network analyzer Agilent PNA series E8363B and freezer and heating chamber TNC-80 were used to measure electromagnetic parameters of natural and artificial substances under temperature influences. LabView 2016 software was used to the virtual instrument generation. This virtual instrument is needed for efficient electromagnetic parameter and temperature measurement automation. The virtual instrument framework and faceplate of the virtual instrument are shown. The present work involves an experimental study of the magnetic permeability of ferrites with hexagonal structure under temperature influences. It is show that there is a nonlinear influence of temperature on magnetic permeability of W-type ferrites.


Sign in / Sign up

Export Citation Format

Share Document