Predicting of Compressive Strength of Con-Crete at Early Age by using Ultrasonic Pulse Velocity

Author(s):  
Ziwar Zebari ◽  
2007 ◽  
Vol 34 (5) ◽  
pp. 682-685 ◽  
Author(s):  
D K Panesar ◽  
S E Chidiac

This study evaluates the potential use of ultrasonic pulse velocity (UPV) for determining the early age compressive strength of dry-cast concrete containing varying percentages of ground granulated blast-furnace slag (GGBFS). The proposed approach includes computing the dynamic elastic modulus from UPV measurements, evaluating the static elastic modulus from experimentally measured dynamic-to-static elastic modulus ratios, and determining the compressive strength from the static elastic modulus using formulae suggested in ACI-363. The early age strengths of dry-cast concrete containing varying amount of GGBFS, which are determined using UPV measurements, are in good agreement with the measured strength. The evaluation is also extended to include five datasets reported in published literature for concrete containing varying types and amounts of mineral admixtures. Key words: concrete, compressive strength, dry cast, early age properties, ground granulated blast-furnace slag (GGBFS), ultrasonic pulse velocity (UPV).


2021 ◽  
Vol 71 (343) ◽  
pp. e257
Author(s):  
D. Castillo ◽  
S. Hedjazi

Due to the increasing use of rapid construction methods and the challenges of maintaining construction schedules, a growing demand exists for procedures that can assure quality of work without sacrificing the pace of construction. The quality control of construction materials specifically, the mechanical properties of concrete are among the most important concerns in today’s construction industry. In the present study, the correlation between fiber-reinforced concrete’s compressive strength and dynamic modulus to its ultrasonic pulse velocity is investigated at early ages up to 7 days after mixing. An experimental program involving 189 FRC specimens were designed containing different types of structural fibers, fiber volume fractions, and water-to-cement ratios. Mathematical equations were developed to predict the early-age compressive strength and dynamic modulus of four different types of fiber-reinforced concrete based on ultrasonic pulse velocity. The predicted compressive strength and dynamic modulus from the proposed equations showed good agreement with the measured ones.


2013 ◽  
Vol 12 (3) ◽  
Author(s):  
Sudarmadi Sudarmadi

In this paper a case study about concrete strength assessment of bridge structure experiencing fire is discussed. Assessment methods include activities of visual inspection, concrete testing by Hammer Test, Ultrasonic Pulse Velocity Test, and Core Test. Then, test results are compared with the requirement of RSNI T-12-2004. Test results show that surface concrete at the location of fire deteriorates so that its quality is decreased into the category of Very Poor with ultrasonic pulse velocity ranges between 1,14 – 1,74 km/s. From test results also it can be known that concrete compressive strength of inner part of bridge pier ranges about 267 – 274 kg/cm2 and concrete compressive strength of beam and plate experiencing fire directly is about 173 kg/cm2 and 159 kg/cm2. It can be concluded that surface concrete strength at the location of fire does not meet the requirement of RSNI T-12-2004. So, repair on surface concrete of pier, beam, and plate at the location of fire is required.


2021 ◽  
Vol 13 (4) ◽  
pp. 1881
Author(s):  
Mei-Yu Xuan ◽  
Yi Han ◽  
Xiao-Yong Wang

This study examines the hydration–mechanical–autogenous shrinkage–durability–sustainability properties of ternary composites with limestone filler (LF) and ground-granulated blast furnace slag (BFS). Four mixtures were prepared with a water/binder ratio of 0.3 and different replacement ratios varying from 0 to 45%. Multiple experimental studies were performed at various ages. The experimental results are summarized as follows: (1) As the replacement levels increased, compressive strength and autogenous shrinkage (AS) decreased, and this relationship was linear. (2) As the replacement levels increased, cumulative hydration heat decreased. At the age of 3 and 7 days, there was a linear relationship between compressive strength and cumulative hydration heat. (3) Out of all mixtures, the ultrasonic pulse velocity (UPV) and electrical resistivity exhibited a rapid increase in the early stages and tended to slow down in the latter stages. There was a crossover of UPV among various specimens. In the later stages, the electrical resistivity of ternary composite specimens was higher than plain specimens. (4) X-ray diffraction (XRD) results showed that LF and BFS have a synergistic effect. (5) With increasing replacement ratios, the CO2 emissions per unit strength reduced, indicating the sustainability of ternary composites.


2014 ◽  
Vol 605 ◽  
pp. 147-150
Author(s):  
Seong Uk Hong ◽  
Seung Hun Kim ◽  
Yong Taeg Lee

This study used the ultrasonic pulse velocity method, one of the non-destructive test methods that does not damage the building for maintenance of to-be-constructed concrete structures using recycled aggregates in order to estimate the compressive strength of high strength concrete structure using recycled coarse aggregate and provide elementary resources for technological establishment of ultrasonic pulse velocity method. 200 test pieces of high strength concrete 40, 50MPa using recycled coarse aggregate were manufactured by replacement rates (0, 30, 50, 100%) and age (1, 7, 28, 180days), and air curing was executed to measure compressive strength and wave velocity. As the result of compressive strength measurement, the one with age of 180day and design strength of 40MPa was 43.69MPa, recycled coarse aggregate replacement rate of 30% 50% 100% were 42.82, 41.22, 37.35MPa, and 50MPa was 52.50MPa, recycled coarse aggregate replacement rate of 30% 50% 100% were 49.02, 46.66, 45.30MPa, and while it could be seen that the test piece substituted with recycled aggregate was found to have lower strength than the test piece with natural aggregate only, but it still reached the design strength to a degree. The correlation of compressive strength and ultrasonic pulse velocity was found and regression analysis was conducted. The estimation formula for compressive strength of high strength concrete using recycled coarse aggregate was found to be Fc=0.069Vp4.05, R2=0.66


Sign in / Sign up

Export Citation Format

Share Document