A Proposed Approach to De-speckle an Ultrasound Image using Anisotropic Filter by Generating Diffusion Tensor

Author(s):  
Poonam Chauhan ◽  
Vikas Kaushik

Ultrasound imaging is a technique that is used to diagnose the diseases in medical field using radiology. US (ultrasound) imaging is a non -invasive technique and used for imaging of internal structure of the body without any kind of penetration which helps to identify the diseases that have probability and tissues. Many kinds of noises present in US images but the presence of speckle noise is a big challenge since last few years in biomedical field. Sometimes speckle noise becomes the part of information and vice-versa. So it becomes hard to find the disease for doctors. There are many de-speckled filters available for de-noising. This paper gives a proposed approach to de-speckled the US image using anisotropic diffusion filter by calculating the different numerical values like SSIM (structural similarity index), SNR (signal to noise ratio), MSE (mean square error), PSNR (peak signal to noise ratio), which results in coherence enhancement The proposed technique provides better and improved edge and coherence enhancement in ultrasound image data.

2021 ◽  
Vol 11 (1) ◽  
pp. 399-410
Author(s):  
Kaitheri Thacharedath Dilna ◽  
Duraisamy Jude Hemanth

Abstract Ultrasonography is an extensively used medical imaging technique for multiple reasons. It works on the basic theory of echoes from the tissues under consideration. However, the occurrence of signal dependent noise such as speckle destroys utility of ultrasound images. Speckle noise is subject to the composition of image tissue and parameters of image. It reduces the effectiveness of many image processing steps and decreases human perception of fine details form ultrasound images. In many medical image processing methods, despeckling is used as the preprocessing step before segmentation and feature extraction. Many speckle reduction filters are proposed but while combining many techniques some speckle diagnostic information should be preserved. Removal of speckle noise from ultrasound image by preserving edges and added features is a great challenging task in ultrasound image restoration. This paper aims at a comprehensive description and comparison of reduction of speckle noise of ultrasound fibroid image. Many filters are applied on ultrasound scanned images and the performance is marked in terms of some statistical measures. Even though several despeckling filters are there for speckle reduction, all are not good for ultrasound scanned images. A comparison of quality measures such as mean square error, peak signal-to-noise ratio, and signal-to-noise ratio is done in ultrasound images in despeckling.


Thyroid ultrasonography is the most common and extremely useful, safe, and cost effective way to image the thyroid gland and its pathology. However, an inherent characteristic of Ultrasound (US) imaging is the presence of multiplicative speckle noise. Speckle noise reduces the ability of an observer to distinguish fine details, make diagnosis more difficult. It limits the effective implementation of image analysis steps such as edge detection, segmentation and classification. The main objective of this study is to compare the performance of various spatial and frequency domain filters so as to identify efficient and optimum filter for de-speckling Thyroid US images. The performance of these filters is evaluated using the image quality assessment parameters Signal to Noise Ratio (SNR), Peak Signal to Noise Ratio (PSNR), Structural Similarity Index (SSIM), Mean Square Error (MSE) and Root Mean Square Error (RMSE) for different speckle variance. Experimental work revealed that kuan filter resulted in higher PSNR, SNR, SSIM and least MSE, RMSE values compared to other filters


2020 ◽  
Vol 25 (2) ◽  
pp. 86-97
Author(s):  
Sandy Suryo Prayogo ◽  
Tubagus Maulana Kusuma

DVB merupakan standar transmisi televisi digital yang paling banyak digunakan saat ini. Unsur terpenting dari suatu proses transmisi adalah kualitas gambar dari video yang diterima setelah melalui proses transimisi tersebut. Banyak faktor yang dapat mempengaruhi kualitas dari suatu gambar, salah satunya adalah struktur frame dari video. Pada tulisan ini dilakukan pengujian sensitifitas video MPEG-4 berdasarkan struktur frame pada transmisi DVB-T. Pengujian dilakukan menggunakan simulasi matlab dan simulink. Digunakan juga ffmpeg untuk menyediakan format dan pengaturan video akan disimulasikan. Variabel yang diubah dari video adalah bitrate dan juga group-of-pictures (GOP), sedangkan variabel yang diubah dari transmisi DVB-T adalah signal-to-noise-ratio (SNR) pada kanal AWGN di antara pengirim (Tx) dan penerima (Rx). Hasil yang diperoleh dari percobaan berupa kualitas rata-rata gambar pada video yang diukur menggunakan metode pengukuran structural-similarity-index (SSIM). Dilakukan juga pengukuran terhadap jumlah bit-error-rate BER pada bitstream DVB-T. Percobaan yang dilakukan dapat menunjukkan seberapa besar sensitifitas bitrate dan GOP dari video pada transmisi DVB-T dengan kesimpulan semakin besar bitrate maka akan semakin buruk nilai kualitas gambarnya, dan semakin kecil nilai GOP maka akan semakin baik nilai kualitasnya. Penilitian diharapkan dapat dikembangkan menggunakan deep learning untuk memperoleh frame struktur yang tepat di kondisi-kondisi tertentu dalam proses transmisi televisi digital.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5540
Author(s):  
Nayeem Hasan ◽  
Md Saiful Islam ◽  
Wenyu Chen ◽  
Muhammad Ashad Kabir ◽  
Saad Al-Ahmadi

This paper proposes an encryption-based image watermarking scheme using a combination of second-level discrete wavelet transform (2DWT) and discrete cosine transform (DCT) with an auto extraction feature. The 2DWT has been selected based on the analysis of the trade-off between imperceptibility of the watermark and embedding capacity at various levels of decomposition. DCT operation is applied to the selected area to gather the image coefficients into a single vector using a zig-zig operation. We have utilized the same random bit sequence as the watermark and seed for the embedding zone coefficient. The quality of the reconstructed image was measured according to bit correction rate, peak signal-to-noise ratio (PSNR), and similarity index. Experimental results demonstrated that the proposed scheme is highly robust under different types of image-processing attacks. Several image attacks, e.g., JPEG compression, filtering, noise addition, cropping, sharpening, and bit-plane removal, were examined on watermarked images, and the results of our proposed method outstripped existing methods, especially in terms of the bit correction ratio (100%), which is a measure of bit restoration. The results were also highly satisfactory in terms of the quality of the reconstructed image, which demonstrated high imperceptibility in terms of peak signal-to-noise ratio (PSNR ≥ 40 dB) and structural similarity (SSIM ≥ 0.9) under different image attacks.


2015 ◽  
Vol 60 (21) ◽  
pp. 8549-8566 ◽  
Author(s):  
Elodie Tiran ◽  
Thomas Deffieux ◽  
Mafalda Correia ◽  
David Maresca ◽  
Bruno-Felix Osmanski ◽  
...  

2020 ◽  
Vol 10 (6) ◽  
pp. 1930
Author(s):  
Chengkun Fu ◽  
Huaibin Zheng ◽  
Gao Wang ◽  
Yu Zhou ◽  
Hui Chen ◽  
...  

Three-dimensional (3D) imaging under the condition of weak light and low signal-to-noise ratio is a challenging task. In this paper, a 3D imaging scheme based on time-correlated single-photon counting technology is proposed and demonstrated. The 3D imaging scheme, which is composed of a pulsed laser, a scanning mirror, single-photon detectors, and a time-correlated single-photon counting module, employs time-correlated single-photon counting technology for 3D LiDAR (Light Detection and Ranging). Aided by the range-gated technology, experiments show that the proposed scheme can image the object when the signal-to-noise ratio is decreased to −13 dB and improve the structural similarity index of imaging results by 10 times. Then we prove the proposed scheme can image the object in three dimensions with a lateral imaging resolution of 512 × 512 and an axial resolution of 4.2 mm in 6.7 s. At last, a high-resolution 3D reconstruction of an object is also achieved by using the photometric stereo algorithm.


2017 ◽  
Vol 2017 ◽  
pp. 1-13
Author(s):  
Shanshan Chen ◽  
Bensheng Qiu ◽  
Feng Zhao ◽  
Chao Li ◽  
Hongwei Du

Compressed sensing (CS) has been applied to accelerate magnetic resonance imaging (MRI) for many years. Due to the lack of translation invariance of the wavelet basis, undersampled MRI reconstruction based on discrete wavelet transform may result in serious artifacts. In this paper, we propose a CS-based reconstruction scheme, which combines complex double-density dual-tree discrete wavelet transform (CDDDT-DWT) with fast iterative shrinkage/soft thresholding algorithm (FISTA) to efficiently reduce such visual artifacts. The CDDDT-DWT has the characteristics of shift invariance, high degree, and a good directional selectivity. In addition, FISTA has an excellent convergence rate, and the design of FISTA is simple. Compared with conventional CS-based reconstruction methods, the experimental results demonstrate that this novel approach achieves higher peak signal-to-noise ratio (PSNR), larger signal-to-noise ratio (SNR), better structural similarity index (SSIM), and lower relative error.


Sign in / Sign up

Export Citation Format

Share Document