Study of stationary modes of sucker rod pumping unit operation

2016 ◽  
Vol 1 (12) ◽  
pp. 257-261
Author(s):  
Andriy MALYAR
2017 ◽  
Vol 68 (10) ◽  
pp. 2289-2292
Author(s):  
Dorin Badoiu ◽  
Georgeta Toma

One of the solutions to reduce the production and maintenance costs of the sucker rod pumping installations is to develop automated systems for regulating and controlling their operations. The development of these automated systems requires an attentive modeling of the dynamics of the mechanism of the pumping unit, process in which the identification of the values of the parameters involved in the calculations plays an essential role. The paper presents the manner of determining the values of some parameters of the mechanism of a C-320D-256-100 pumping unit starting from the variation on a cinematic cycle of the motor torque at the crank shaft. Simulations were performed with a computer program developed by the authors, and the experimental records were processed with the program Total Well Management.


2014 ◽  
Vol 630 ◽  
pp. 158-165
Author(s):  
Mykola I. Sotnyk ◽  
Serhii Sapozhnikov ◽  
Kateryna Prykhodko

The influence of pumping unit’s elements on the overall energyefficiency of its work is viewed in the article. The areas of pumping unit’s operation effectiveness are identified and evaluated within the field of his QH characteristics and efficiency of its use in real technological process. The methodology of pumping unit’s operation evaluation in different modes through indicators of unit electrical energy consumption is developed.


2013 ◽  
Vol 10 (1) ◽  
pp. 73-80 ◽  
Author(s):  
Kun Li ◽  
Xianwen Gao ◽  
Zhongda Tian ◽  
Zhixue Qiu
Keyword(s):  

2019 ◽  
pp. 82-91 ◽  
Author(s):  
A. S. Galeev ◽  
G. I. Bikbulatova ◽  
R. N. Suleymanov ◽  
O. V. Filimonov ◽  
S. L. Sabanov ◽  
...  
Keyword(s):  

2021 ◽  
Author(s):  
Yuzar Aryadi ◽  
Azis Hidayat ◽  
Hilman Lazuardi ◽  
Syahroni Isnanto ◽  
Bonni Ariwibowo ◽  
...  

Abstract SCADA optimization platform is implemented to monitor and evaluate well performance. For Sucker Rod Pump, SCADA Optimization Software can be used to monitor the unit balance and gearbox torque. In some ways, not all required well configuration data for SCADA Optimization Software to do a calculation of counterbalance torque (CBT) for pumping unit balance and gearbox torque evaluation are available. Standard field Counterbalance Effect (CBE) measurement might be performed to calculate the CBT value. However, this standard procedure is limited to well that run on balance condition. For well with unbalance condition, the measured CBE needs to be adjusted by a correction factor which the equation will be presented in this paper. The corrected CBE value from the new equation is then inputted to the SCADA Optimization software to perform day-to-day real-time monitoring of pumping unit balance and gearbox torque. Derivation of the CBE correction factor equation is presented. Validation upon this new equation is performed by comparing the result with electrical measurement on the pumping unit motor. Using the calculated CBT from the new equation, SCADA Optimization Software performs gearbox torque and pumping unit balance analysis based on every collected dynamometer card. Calculated CBT from the new equation provided results in gearbox torque distribution pattern that match with measured electrical parameter distribution along the stroke. This CBT value assists SCADA optimization software to calculate pumping unit balance and gearbox torque. Alarm in the SCADA optimization software that coming from an anomaly on pumping unit balance and gearbox torque help operator to do preventive maintenance so that pumping unit component especially the gearbox could have longer run life.


Author(s):  
Guixi Li ◽  
Rujian Ma ◽  
Jungang Wang

The dynamic performance of hydraulic beam pumping units was analyzed in this paper by using the theory of mechanical vibrations. The house-head movement of the pumping unit is mainly uniform, except the alternation period of upper- and down-strokes. Under the action of the house-head movement, the vibration of the system, the sucker-rod and, furthermore, the dynamic stress will be induced. The results indicate that the movement of the downhole pump includes two parts. One is the movement following the horse-head. The other is the dynamic response excited by the support movement. When the parameters of the system are selected reasonably, over-stroke of the pump will appear. This is because the movement of the hydraulic piston obeys a particular law. The maximum displacement increases, and the maximum dynamic stress decreases with depth. The changing of maximum dynamic stress with depth obeys quadratic law.


Sign in / Sign up

Export Citation Format

Share Document