Abstract This paper reports the use of scanning thermal microscopy (SThM) for studying heat dissipation and phonon transport in nanoelectronic circuits consisting of carbon nanotubes (CNs). Thermally designed and batch fabricated SThM probes were used to resolve the phonon temperature distribution in the CN circuits with a spatial resolution of 50 nm. Heat dissipation at poor metal-CN contacts could be readily found by the thermal imaging technique. Important questions regarding energy transport in nanoelectronic circuits, such as where is heat dissipated, whether the electrons and phonons are in equilibrium, how phonons are transported, and what are the effects of mechanical deformation on the transport and dissipation properties, are addressed in this work.


2018 ◽  
Vol 7 (4.3) ◽  
pp. 361 ◽  
Author(s):  
Andriy Sumtsov ◽  
Anatoliy Falendysh ◽  
Nataliya Chyhyryk ◽  
Oleg Vasilenko

This article is concerned with the problem of energy savings and rise of comfortableness of railway rolling stock. Done analysis has shown the insufficient paying attention to the energy efficiency of suburban rolling stock. In particular, to the problem of heat comfort for passengers. For this purpose, a procedure was carried out for the thermal audit of electric trains, taking into account the prevailing array of required indicators. To determine the sites of local heat losses, there was done the thermal-imaging inspection of the electrical train ER2 series during which it was determined the local sites of heat losses and entry of cold air. Besides the passenger compartment, there were inspected the outer body liner and driver's cabin. As a result of inspection of driver's cabin, it was found the bad quality of a sealing layer for side small windows from one side. On the basis of inspection, the recommendations for elimination of found irregularities were developed.   


2012 ◽  
Vol 44 (5) ◽  
pp. 1456-1462 ◽  
Author(s):  
Elizabeth Azhikannickal ◽  
Philip J. Bates ◽  
Gene Zak

2012 ◽  
Vol 54 (5) ◽  
pp. 340-346 ◽  
Author(s):  
M. J. Suriani ◽  
Aidy Ali ◽  
A. Khalina ◽  
S. M. Sapuan ◽  
S. Abdullah ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document